36 -- High Performance Vapor Degreasing System

Notice Date
1/25/2002
 
Notice Type
Modification
 
Contracting Office
Department of the Navy, United States Marine Corps, Marine Corps Air Bases East - RCO, PSC Box 8018, Cherry Point, NC, 28533-0018
 
ZIP Code
28533-0018
 
Solicitation Number
M00146-02-Q-N041
 
Response Due
1/30/2002
 
Archive Date
2/14/2002
 
Point of Contact
Debora Berget, Purchasing Agent, Phone 252-466-7766, Fax 252-466-4056,
 
E-Mail Address
bergetda@cherrypoint.usmc.mil
 
Small Business Set-Aside
Total Small Business
 
Description
The Naval Aviation Depot at the Marine Corps Air Station, Cherry Point, NC has a requirement for the procurement and installation of a high performance vapor degreasing system. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. A quotation is being requested and a written solicitation will not be issued. Solicitation number M00146-02-Q-N041 is hereby issued as a Request for Quotation. The incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2001-01 and Defense Acquisition Circular 98-27. This acquisition is 100% set-aside for Small Business and is under the North American Industry Classification System code 333298, with a small business size standard of 500 employees. This requirement is for a firm fixed priced contract, BRAND NAME OR SIMILAR for the following item: Nomenclature: Vapor Degreaser. Brand name designation: Model HPD2420 High Performance Degreasing System. Source: Greco Brothers Incorporated, 1 Greco Lane, Providence, RI 02909-2616. Quantity: One (1) Each. ESSENTIAL CHARACTERISTICS: The unit shall be provided with the following minimum characteristics. 1. Co-Solvent Process. The degreaser shall be capable of degreasing aircraft engine components using a co-solvent or single solvent process utilizing 3M Hydrofluoroether materials, HFE-7100, HFE-71DE, and solvating agents 24 and 70 from Petrofirm. 2. Dual Sump. The degreaser shall be a dual sump type consisting of a boil chamber and a rinse chamber. The working (inside) dimensions of each sump shall be at least 24 inches long by 20 inches wide by 18 inches deep. 3. Construction. All internal surfaces shall be constructed of stainless steel compatible with the process fluid and shall be seamlessly welded and leak free. Exterior surfaces shall be of coated or non- coated metal that is compatible with the 3M Hydrofluoroether materials. The footprint of the degreaser shall not exceed 130inches by 60 inches. 4. Refrigeration. Equipment or material containing Class 1 Ozone Depleting Substances (ODS) shall not be used in the system. The system shall be capable of maintaining primary refrigeration from 35-45 degrees F. and secondary refrigeration to minus 20 degrees F. or colder. The secondary refrigeration shall create a blanket of cold air across both sumps at least 8 inches deep. The unit shall have separate refrigeration systems to supply both primary and secondary cooling. The refrigeration capacity shall at a minimum exceed the heaters capacity by 110%. The system shall be a stand-alone unit and shall not require mechanical ventilation for safe operation. 5. Filter System. Both sumps shall be equipped with a re-circulating filtration system to clean the fluid to 5 microns absolute in the boil sump and 1 micron absolute in the rinse sump. The filter flow rate shall be compatible with the pump provided. The filters shall be standard size and readily available. Both filters shall have shutoff valves. 6. Ultrasonics. Both sumps shall have a 38-42 kHz, sinusoidal-sweep, wave type ultrasonic generator. The power shall be adjustable from 0-50 watts per gallon of fluid capacity. The transducers shall be mounted opposite the heaters. 7. Freeboard Ratio. The unit shall have a freeboard ratio of at least 1.25:1. 8. Water Separator. The system shall be equipped with a water separator sized for a minimum residence cycle time of 5 minutes. 9. Spray Wand. The tank shall be equipped with a stainless steel spray wand system. A spare set of spray nozzles shall be provided with the unit. 10. Cover. The unit shall be equipped with a leak proof stainless steel cover to prevent vapor loss into the room when the process is unattended or when the process is not used. The cover shall be secured when in the open position. 11. Pumps. All pumps and seals shall be compatible with 3M Hydorfluoroether materials and shall be constructed of stainless steel. The pumps shall be seal-less and provide a flow that causes a change rate of 6 tanks per hour. 12. Heaters. The heaters shall be sized to maintain a boiling rate that produces the appropriate condensate flow rate. One heater shall operate from zero loads to full heating capacity. A second heater shall be provided to maintain a specific temperature to maximize fluid recovery. Heater skin temperature shall not exceed 392 degrees F. Heat density shall not exceed 20 watts per square inch. 13. Safety Vapor Control Sensor. The unit shall be equipped with a safety vapor control sensor that turns off heat automatically if vapors rise above the primary cooling coil. The control shall be manually reset. 14. High Temperature Control. The unit shall be equipped with a high temperature control that will turn off the heat if the heating element becomes too hot. The control shall be manually reset. 15. Liquid Temperature Control. The unit shall be equipped with a digital temperature display of the liquid temperature and liquid temperature control switch that turn off the heat based on a set point of the boiling solvent tank. The switch shall be manually reset. 16. Low-level Control. The unit shall be equipped with a switch that shuts off the heat if the liquid solvent level is too low. The switch shall be self-resetting. 17. Vapors Up Pump Control. The unit shall be equipped with a vapor up control that will shut off the spray pump to prevent solvent from being sprayed above the cold air blanket or if the vapor level is too low. The switch shall be self-resetting. 18. Electrical Power. The unit shall operate from a 480 VAC, 3 phase, 60-hertz electrical power source. 19. Baskets. Four stainless steel baskets shall be provided sized appropriately for the inside (working) dimensions of the tank. 20. Codes. The unit shall comply with all OSHA and NFPA codes and regulations governing this equipment. DOCUMENTATION: Three copies each of the operation and maintenance manuals shall be provided. The operation manuals shall provide complete instruction on the units operation. Preventive maintenance instructions shall be provided as well as a suggested spare parts list. EQUIPMENT MARKINGS: Name, manufacturer, type, model, and serial number of the equipment shall be displayed on the equipment in permanent markings. ADDRESS: All documentation as required herein shall be delivered to the following address: Naval Aviation Depot, Code 6.9, Building No. 4225, PSC Box 8021, Cherry Point, NC 28533-0021. WARRANTY: All furnished equipment shall be guaranteed against defects in workmanship and materials for not less than one year after acceptance. The contractor, at no cost to the government, shall correct any deficiencies. Note: If quoting on a similar item please provide literature on the brand you are quoting. Acceptance shall be made at destination. The required delivery date for the above item is 16 weeks after receipt of order or sooner. The Government will award a purchase order resulting from this Request for Quotation to the technically acceptable, responsive, responsible offeror based on price alone. The following clauses and provisions are incorporated and are to remain in full force in any resultant purchase order: FAR 52.212-1, Instructions to Offers - Commercial Items (Oct 2000). FAR 52.212-3 Alternate I, Offer Representation and Certifications-Commercial Items (Oct 2000), a completed copy of this provision shall be submitted with the offer. FAR 52.212-4, Contract Terms and Conditions Commercial Items (May 2001). FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items (May 2001), to include clauses (11) (12) (13) (14) (15) (16) (21) (24) and (26). DFARS 252.204-7004 Required Central Contractor Registration (Nov 2001). DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (NOV 2001), applies with the following clauses applicable for paragraph (b); DFARS 252.206-7000, Domestic Source Restriction; DFARS 252.225-7001, Buy American Act and Balance of Payment Program; and DFARS 252.225-7012, Preference for Certain Domestic Commodities. DFARS 252.204-7004 Required Central Contractor Registration. DFARS 252.225-7000 Buy American Act -- Balance of Payments Program Certificate. The request for quote is to be priced FOB destination FAR 52.247-34. Request for quote must be received no later than 3:oo PM, local time, 25 January 2002. You may Email or fax your quote to the above. Offers sent via the US Postal Service should be mailed to Supply Directorate, Attn: Debora Berget code SUL-3G, Supply MCAS, PSC Box 8018, Cherry Point, NC 28533-0018. All quotes not sent through the US mail will be considered to be hand carried and direct delivered. Hand carried quotes (excluding Email and faxes) must be delivered directly to Cunningham Street, building 159, first floor, MCAS, Cherry Point, NC, Contracting Department. Direct delivery of quote is only possible during weekdays, excluding federal holidays, between the hours of 8:00 AM and 4:00 PM. As of 31 May 1999, all Contractors must be registered in the Central Registration (CCR) Database as a condition of contract award. Contractors may register in the CCR database through the World Wide Web at www.ccr.gov or call 888-227-2423 for assistance.
 
Record
SN20020127/00018996-020125210218 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(will not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.