SOLICITATION NOTICE
54 -- Guard Shelter
- Notice Date
- 2/27/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- Sierra Army Depot, Building 74, Herlong, CA 96113-5009
- ZIP Code
- 96113-5009
- Solicitation Number
- DAAA12-02-T-0019
- Response Due
- 3/15/2002
- Archive Date
- 4/14/2002
- Point of Contact
- Tracy Marino, 530-827-4831
- E-Mail Address
-
Email your questions to Sierra Army Depot
(tmarino@sierra.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- NA This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. A written soli citation will not be issued. The solicitation document and incorporated provisions and clauses are those in effect through Dederal Acquisition Circular 2001-4. Response date for this solicitation is 15 March 2002. NOTE 1 Applies. CLIN 0001: his stateme nt concerns the minimum government requirements covering high security level 4, guard shelters tested and certified by UL752 requirements. These units are to be impact resistant to include high explosives and high-powered rifles. The following statements p rovide the minimum acceptable construction standards. REQUIREMENTS: A) Frame work shall be constructed of 2 in. X 3 in. X .120 in A500 tube with 3 in. X 3 in. X .120 in A500 TUBE. Minimum width of the unit shall be 6'-0 by a length of 10'-0 for the outsid e dimensions; B) Unit shall have level 4 bullet resistant wall systems. The system is to meet or exceed Underwriters Laboratories standards UL 752, level 4, table 3.1, revised 1/27/95 for velocities of 2540 fps; C) Unit shall have a 'hip' style roof with 8 in. fascia and 24 in. overhangs on all sides; D) Unit shall have four 3/4 in. shank lifting eyes mounted on the roof. Lifting eyes shall be designed for straight lift; E) Unit shall have a minimum of 11 gauges A569 steel floor. Floor shall be covered with a minimum of 7/8 in. black rubber matting or tile that meet current ergonomic recommendations for standing long durations; F) Unit shall have the underside fully coated with a bituminous undercoating sealant: G) Unit shall have two interior sliding doors with rigid steel rollers. Mortise hook type locking hardware, keyed outside and thumb turn inside. Doors shall include weather stripping. Doors shall include full-length glass meeting level 4 requirements; H) Unit shall have level 4 bullet resistant tinted glasses; Glazing shall meet or exceed Underwriters Laboratories standards UL 752, level 4, table 3.1, revised 1/27/95; I) Units shall have a minimum of two each 12 in. X 48 in. 2-tube fluorescent interior lighting fixtures. Interior fixtures shall be rece ssed in the ceiling. Additionally, traffic control lights (stop and go signals) shall be mounted on the ends of the units with controls mounted on the interior of the unit. Soffit lighting shall be installed on the two sides to provide exterior light for i nspections. Exterior lighting shall be recessed into the soffit: J) Units shall have two duplex 120V outlets. One mounted on each side of the unit; K) Unit shall have a steel shelf full width of the unit by 20 in. deep. Shelf shall be capable of supporting a minimum of 250 lb.; L) Unit shall be pre-wired for all electrical connections. Unit shall have a minimum of 125-amp 120/240V single phase 6/12 pole load center. Units shall be wired to receive exterior connections from underground utility feeds; M) Unit shall have one 18 in. deep by 36 in. X 36 in. length and width computer cabinet with interlocking doors. Cabinet is to be mounted on the opposite wall from the shelf. The cabinet shall include one each 3 in. diameter wall penetration to receive on site wi ring requirements. All penetrations shall have a level 4 shields on the exterior side; N) Unit shall have a wall mounted heat/cool air conditioner with 11,600 BTU cool capability and 11,600 BTU heating capability at 230 volts. Heat/Cool unit is to be cover ed on the exterior with a level 4 bullet resistant painted metal shrouds; O) Unit shall have insulated walls, ceilings and floor. Minimum wall 'R' value shall be R-11; roof value shall meet R-19 with a floor value of R-11; P) Unit shall have 4 each interio r anchor clips to allow the unit to be secured to a concrete pad; Q) All exposed steel surfaces shall be coated with a rust inhibitor then two coats of a colore d finish coating. Colors for the exterior roof shall be 'forest green' with a light 'sand tan' for the walls. Interior walls and ceiling shall be 'off white' in color. All offerors are required to provide A) Manufacturers cut sheet for type of heating/coo ling unit to be utilized; B) Two copies of the manufacturers proposed floor layout detailing interior item location; C) Two prints detailing the unit exterior elevations, measurements and lighting. Del to SIERRA ARMY DEPOT BUILDING 304 NORTH, HERLONG, CA, 96113. Delivery date: 60-90 Days ARO. The following FAR and DFARS provisions apply to this acquisition and will be included by reference or in full text, as appropriate, any any subsequent award document: 52.212-1 Instructions to Offerors - Commercial Items; 52.214-4 Contract Terms and Conditions - Commercial Items; 52.212-5 Contract Terms and Conditions Required to implement Statutes or Executive Orders - Commercial Items (including 52.203-6, 52.219-8, 52.219-14, 52.222-3, 52.222-21, 52.222-26, 52.222- 35, 52.222-36, 52.222-37, 52.232-33); 52.247-34 F.O.B. Destination; 252.204-7004 Required Central Contractor Registration; 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of C ommercial Items (including 52.203-3, 252.225-7036, 252.243-7002, 252.247-7023, 252.247-7024); 252.225-7035 Buy American Act-North American Free Trade Agreement Implementation Act - Balance of Payments Program Certificate; 52.252-2 Clauses Incorporated by R eference. Inspection and Acceptance will be at destination. Responses may be faxed to 530-827-4722 Attn Tracy Marino.
- Place of Performance
- Address: Sierra Army Depot Building 74, Herlong CA
- Zip Code: 96113-5009
- Country: US
- Zip Code: 96113-5009
- Record
- SN00031827-W 20020301/020227213240 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |