Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 03, 2002 FBO #0091
SOLICITATION NOTICE

66 -- Automated High Resolution Gel Permeation Chromatography Systems

Notice Date
3/1/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of Health and Human Services, Center for Disease Control and Prevention, Procurement and Grants Office (Atlanta), 2920 Brandywine Road, Room 3000, Atlanta, GA, 30341-4146
 
ZIP Code
30341-4146
 
Solicitation Number
2002-Q-00370
 
Response Due
3/18/2002
 
Archive Date
4/2/2002
 
Point of Contact
Lenore Mickle, Contract Specialist, Phone (770)488-2606, Fax (770)488-2670, - Lenore Mickle, Contract Specialist, Phone (770)488-2606, Fax (770)488-2670,
 
E-Mail Address
LMickle@CDC.GOV, LMickle@CDC.GOV
 
Description
The Centers for Disease Control and Prevention (CDC) intends to purchase two Automated High Resolution Gel Permeation Chromatography Systems made by Gilson, Inc. for the rapid method of analysis for PCBs and persistent pesticides in human serum. The Gilson 215 Liquid Handler is the only known system that can be customized and coupled with Gilson High Performance Liquid Chromatography (HPLC) which is used by the CDC. CDC believes that its requirements are met by only one provider; however, all responsible sources that can meet the requirements listed herein may submit a quote which will be considered by the agency. Description of the system: The 215 Liquid Handler is a fast accurate single-probe instrument with dual function sample injection and fraction collection from the same bed; Flexible large capacity bed with more than 30 standard racks; Custom software and racks to meet demands of applications; Direct injection into HPLC or LC/MS with optional injection module; and, Custom or standard racks available to support any laboratory. Features include: Open architecture for easy access to racks; Liquid level sensing probe that minimizes the risk of cross-contamination from carry-over; Versatility of using up to 480 (13x100mm) test tubes, seventeen 96 well and seventeen 384* well microplates; Flexibility of utilizing microplates and test tubes on the same bed; Durable, chemically resistant tray and case protects against damage from spills; Microsoft Windows icon-based software with a graphical tray editor makes automated setup fast and easy; and, Accommodates sample vessels such as microplates, microcentrifuge vials, test tubes, scintillation vials and bottles. The following components and quantities are to be purchased: 1) 306 Pump CTL Module, 110V. Model 306 HPLC Pump Control Module specifically designed for multi-pump systems, the 306 pump must be controlled by either a Gilson HPLC System Controller or Gilson Model 305 Programmable HPLC Pump. Includes flow rate range of 0.010-200 ml/min with nine interchangeable single piston pump heads, maximum pressure rating 8700 psi with 5 SC (5 ml/min) pump head, maximum accuracy error of plus/minus 1% with water over the full flowrate and pressure ranges, operating temperature range of 0-40 deg C, CV of 0.1-0.6% with aqueous solutions or hydro-organic polar solvent mixtures and 0.3-1% with hydrocarbons or chlorinated volatile solvents, externally-controlled modes for constant flowrate and constant volume (dispensing). Dimensions (WxDxH) 33x33x15 cm (13x13x6in). 100/115V, 50/60Hz. Quantity 2 ea. 2) Model 805 Manometric Module, 0-10 ml/min, 8700 psi. Low dead volume pulse dampener/transducer reduces residual pulsation to less than 1% of system operating pressure. For use with Model 305/306 pumps. Flowrate range of 0.025-10 ml/min, maximum pressure of 8700 psi. All liquid-contact parts are titanium or fluoroplastics. Dimensions (WxDxH) 22x16x13.5 cm (8.7x6.3x3in). Quantity 2 ea. 3) Model 10 Pump Head, 10SC, 10 ml/min 3000 psi. Flowrate range is 0.050 to 10 ml/min. Maximum operating pressure is 8700 psi with 305/306/307 pump modules. Stroke volume is 79.2 ul. Includes self-centering piston for extended seal life; cartridge-type check valves; and solvent resistant materials. Quantity 2 ea. 4) Spare Parts Kit, 10SC Pump Head. Includes 1 each inlet and outlet check valve cartridge, 2 piston seals, 1 inlet filter, 2 outlet filters, 1 anti-extrusion gasket. Quantity 2 ea. 5) 156 UV/VIS Detector w/5mm Analy Cell. 12 ul 5mm analytical flow cell/accessory kit. Programmable, variable wavelength detector with single, dual and scan wavelength detection options; 190-700 nm. Control of detector parameters must be carried out through UniPoint (TM) control. An event marker cable (switch closure actuation) and recorder cable (banana plugs) are supplied. 100-240V. 50/60Hz. Quantity 2 ea. 6) Model 506C System Interface Module, 110V, for bidirectional communication between an MSDOS computer and Gilson instruments. Provides four contact inputs and six contact outputs for control of peripheral devices. Incorporates Gilson software security key port and four analog inputs to read signals from detectors or monitors with up to 1000mV analog output. Quantity 2 ea. 7) 215 Liquid Handler without Diluter Pump, 100/115V. Includes 125mm vertical arm, locator plate, rinse station with waste bottle, drain tubing and accessory package. Quantity 2 ea. 8) 402 Syringe Pump, dual module with tee junction, 100/115V. Quantity 2 ea. 9) Syringe, 100 ul, 215/234/235, for 402 Syringe Pump, 234 Autoinjector, 235 Autoinjector and 215 Liquid Handler. Quantity 4 ea. 10) Syringe, 1 ml, 215/235 for 402 Syringe Pump, 215 Liquid Handler, and 235 Autoinjector. Quantity 4 ea. 11) Syringe, 10 ml, 215/235 for 402 Syringe Pump, 235 Autoinjector and 215 Liquid Handler. Quantity 4 ea. 12) Probe Micro SP 221.5x1.5x1.1, Const 45 BV. Micro septum-piercing probe, constricted 45 deg bevel tip, capacitive level sensing, stainless steel. Dimensions 221.5x1.5x1.1 mm ID (tip dimensions 10x0.7x0.4 mm ID). Quantity 2 ea. 13) 215 Probe Holder/Guide Kit for 1.5 mm outer diameter probes. Includes probe holder and probe guide. Quantity 2 ea. 14) 25.5ml Coiled FEP Transfer Tubing. 1.5mm ID x 50 ft. Quantity 2 ea. 15) Rinse Station Insert for non-level sensing applications (deep pocket) with 125mm vertical arm. Quantity 2 ea. 16) Rinse Station Insert for flowing rinse applications (open-bottom) with 125mm vertical arm. Quantity 2 ea. 17) Model MP1 Single Channel Pump, 110/220V. Minipuls 3 Single Channel Peristaltic Pump. Consists of control module and R1 single channel pump head. Features include; microprocessor control, flowrate range of 0.001-50ml/min per channel, stepper motor drive with LCD readout of motor RPM, remote control (start, stop and direction change) via contact closure, motor speed control via 0-5V variable analog input, ten stainless steel rollers for smooth operation and low pulsation, accepts PVC or Viton tubing. Supplied with two pieces of PVC manifold tubing (0.38mm and 3.16mm ID) and one piece of silicone tubing (7mm ID). Other tubing sizes and pump heads available. Dimensions (WxDxH) 15x18x23cm (6x7x9in). 100/115V, 50/60Hz. Quantity 2 ea. 18) MP3 to Rinse Station Interconnection Kit. Quantity 2 ea. 19) MRACK XX. Modified Code 207 rack to work with customer's 16/115mm conical bottom, screw top tube. Quantity 10 ea. 20) Wire. 2-conductor interconnect wire, 6 feet. Quantity 2 ea. 21) 819 Injection Module. 819 Valve Actuator, 100/115V. Includes injection port plate, plumbing and accessory package. Quantity 2 ea. 22) 7010 Valve Assy, 819. Rheodyne 7010 stainless steel injection valve with gear assembly (for 819 Valve Actuator). Quantity 2 ea. 23) Injection Port with PEEK calibrated tubing for 819 Valve Actuator. Designed for 1.3mm OD probe. Includes 1.3mm injection port seal. Quantity 2 ea. 24) 500ul Sample Loop, Stainless Steel. Quantity 2 ea. 25) 200ul Sample Loop, Stainless Steel. Quantity 2 ea. 26) Injection Port Seal for 1.3mm outer diameter probe tip injection port, for 849&889. Quantity 2 ea. 27) 215 Low Pressure Valve Package. Includes low pressure valve, valve mounting assembly and plumbing package required to plumb a 215 Liquid Handler as a fraction collector when controlled by UniPoint (TM) System Software. Also includes UniPoint Technical Note "Using the 215/819 for Injection and Collection." Quantity 2 ea. 28) UniPoint (TM) System Software. Microsoft Windows-based software for HPLC system control, data acquisition and analysis. Features include single point control of Gilson system components, fully integrated control of Gilson autoinjectors, multitasking (reanalyze data, edit methods or run other software programs during a run), multiple system control, real-time data manipulation and run parameter modification, conditional control based on peak parameter checks, extensive statistical and chromatographic data reporting, run calibration standards in regular (sequential or bracketed) or random patterns, user-set report formatting, selectable data rate. Requires 506C System Interface. Recommended computer configuration - Pentium PC processor, 64MB RAM, 2GB fixed disk, color monitor, mouse. Quantity 2 ea. 29) Computer. Dell Pentium III 933MHz GX 150 mini tower system controller with 256MB RAM, 20GB hard drive, 17in color monitor, CD ROM drive, Ethernet card, Microsoft Windows NT4, sound card and speakers, keyboard and mouse. Quantity 2 ea. 30) System Installation and Training per day. Quantity 4 ea. This is an all or none requirement. THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN SUBPART 12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTES ARE BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED. The following provisions apply to this acquisition; 52.212-1 Instructions to Offerors - Commercials Items (MAR 2000) applies to this acquisition; 52.212-2, Evaluation - Commercial Items (JAN 1999); the evaluation criteria stated in paragraph (a) of this provision are as follows: (1) technical capability of the proposed system to meet the requirements stated herein, and (2) price. The clause 52.212-4, Contract Terms & Conditions - Commercial Items (MAY 1999) applies to this acquisition. The following FAR Clauses are hereby added to this clause: 52.247-35 F.O.B. Destination; The clause at 52.212-5 - Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items applies to this acquisition. The following clauses listed in paragraph (b) of 52.212-5 apply to this acquisition: (1), (3), (5), (7), (9), (11), (12), (14), (15), (17), (18), (20) and (24). OFFERORS SHALL INCLUDE A COMPLETED COPY OF THE PROVISION AT 52.212-3, OFFERORS REPRESENTATIONS AND CERTIFICATIONS - COMMERCIAL ITEMS, WITH YOUR QUOTE. The best way to complete this certification is to download the FAR Clauses (Volume II) at http://www.arnet.gov/far, print out the clause 52.212-3, Offeror Representation and Certification, and fill in the appropriate blanks. This procurement is not set-aside for small business. Quotes will be due 3/18/2002, by noon EST at the Centers for Disease Control and Prevention; Facilities and Construction Management Branch; Attn: Lenore Mickle; 2920 Brandywine Road, Room 3000, Atlanta, GA 30341. Facsimile quotes will be accepted at 770-488-2847 or 2819. RFQ# 2002-Q-00370, Attn: Lenore Mickle, shall be clearly marked on the envelope and/or facsimile cover page. All responsible sources that can meet the above requirement may submit a quote, which will be considered by the Agency.*****.
 
Place of Performance
Address: Atlanta, GA
 
Record
SN00034508-W 20020303/020301213105 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.