SOURCES SOUGHT
93 -- This is an unfunded Sources Sought solicitation for foam barricades for munitions storage.
- Notice Date
- 4/1/2002
- Notice Type
- Sources Sought
- Contracting Office
- 147 FW/LGC, BuildingG 1383, Ellington Field, 14657 Sneider Street, Houston, TX 77034-5586
- ZIP Code
- 77034-5586
- Solicitation Number
- DAHA41-02-R-0013
- Response Due
- 4/15/2002
- Archive Date
- 5/15/2002
- Point of Contact
- DEBRA MCGOWAN, 281-929-2743
- E-Mail Address
-
Email your questions to 147 FW/LGC
(debra.mcgowan@txelli.ang.af.mil)
- Small Business Set-Aside
- N/A
- Description
- NA PARTITION SYSTEM, MULTICUBE, COMPOSED OF RIGID POLYEURETHAN FOAM DIVIDERS FOR A 40' X 40' STORAGE AREA. TO BE USED FOR STORAGE OF HIGH EXPLOSIVE MUNITIONS, HAZARD DIVISION CLASS 1.1. FOAM WALL DIVIDERS MUST MEET THE FOLLOWING CRITERIA: POLYURETHANE FOAM , NO METAL PARTS, ENERGY ABSORBING AND ABLE TO REDUCE EXPLOSIVE FORCE AND DAMAGE. DIVIDERS TO BE JOINED BY A SIMPLE SPLINE JOINT, WILL BE FILLED WITH DRY SAND BALLAST. FOAM DIMENSIONS: 7.0 LBS PER CU FT (+/- 10%); CHEMICAL RESISTANCE: EXCELLENT; SERVIC E TEMP RANGE: -65 DEGREES F TO +140F; COMPRESIVE STRENGTH @ 7.5 DEGREESF (ASTM D-1621); PARALLE TO RISE DIRECTIONS: 150 PSI; PERPENDICULAR TO RISE DIRECTION: 115 PSI; SHEAR STRENGTH @ 75 DEGREES F (ASTM C-273); PARALLEL TO RISE DIRECTION: 87.3 PSI; PER PENDICULAR TO RISE DIRECTION: 66.7 PSI; WATER ABSORPTION:0.060LBS/SF; CLOSED CELL CONTENT: GREATER THAN 96%; FLAME RESISTANCE PER Federal Aviation Regulation 25.853(a)(b): PASSES; ADHESIVE JOINTS BOND SIDEWALL DIVIDERS TO EACH OTHER AND TO BASE DIVIDER, KEVLAR CORDS AND PLYWOOD BUTTONS RESTRAIN DIVIDERS FROM BOWING OR MOVING WHEN FILLED WITH SAND, END WALL BUTTRESSES ARE STEEPED TO ALLOW INSTALLERS EASY EGRESS FROM COMPLETED STRUCTURE, NO PAINTING OR OTHER FINISHING OF THE SYSTEM IS REQUIRED, DIMENSIONS: 4 EACH - 16'W X 7'H X 3'D; 6 EACH - 12'W X 7'H X 3'; 4 EACH = 11'W X 7'W X 3'; 2 EACH - 43'W X 7'H X 3'; 2 EACH - 27'W X 7'H X 3'. COST SHOULD INCLUDE ONE ON-SITE TECHNICAL SUPERVISORY WORKER TO TRAIN ASSEMBLERS IN BASEC CONSTRUCTION METHOD FOR THE SYSTE M AND ASSIST IN THE ERECTION AND COMPLETION OF THE INSTALLATION. Note 22 PROPOSALS MAY BE FAXED TO 281-929-2748 OR EMAILED TO debra.mcgowan@txelli.ang.af.mil or michelle.angle@txelli.ang.af.mil
- Place of Performance
- Address: 147 FW/LGC Building 1383, Ellington Field, 14657 Sneider Street Houston TX
- Zip Code: 77034-5586
- Country: US
- Zip Code: 77034-5586
- Record
- SN00051651-W 20020403/020401213231 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |