Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 31, 2002 FBO #0180
SOURCES SOUGHT

66 -- GC/FLAME IONIZATION DETECTOR SYSTEM

Notice Date
5/29/2002
 
Notice Type
Sources Sought
 
Contracting Office
US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch, ATTN: AMSSB-ACC-A, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
 
ZIP Code
21005-3013
 
Solicitation Number
DAAD05-02-T-0436
 
Response Due
6/12/2002
 
Archive Date
7/12/2002
 
Point of Contact
Kathleen Wissler, 410-278-0891
 
E-Mail Address
Email your questions to US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch
(KATHLEEN.WISSLER@SBCCOM.APGEA.ARMY.MIL)
 
Small Business Set-Aside
N/A
 
Description
NA This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are be ing requested and a written solicitation will not be issued. The combined synopsis/solicitation number is DAAD05-02-T-0436. This requirement is a brand name or equal and shall be awarded on an ?all or none? basis. If providing equal, provide sufficient description/descriptive literature of the physical, functional, or performance characteristics of the item for comparison purposes. CLIN 0001 GC/Flame Ionization Detector System. GC/Flame Ionization Detector System shall include: a) #G1540N, 6890N Netw ork GC System Custom, includes special configuration, LAN and RS-232 interfaces, and 7683 interface, detector EPC board, 6 temp ramps, 6 heated zones plus oven, 2 analog out. Configuration: 240V Oven power supply: Included Capillary S/SI inlet with EPC 2 each of these, cap PTV Inlet, w/EPC, Septumless, LN2 FID w/EPC for capillary column only, Factory plumbing For quick installation, Cryogenic oven cooling with liquid N2, installation (44K), Hands-on-training at time of installation (44L), verify system pe rformance (44U), 1 each; b) #G1540N, 6890N Network GC System Custom, includes special configuration, LAN and RS-232 interfaces, and 7683 interface, detector EPC board, 6 temp ramps, 6 heated zones plus oven, 2 analog out. Configuration: 240V Oven power su pply: Included Capillary S/SI inlet with EPC Cap PTV inlet, w/EPC, Septumless, LN2 FID w/EPC, for capillary column only Factory plumbing for quick installation Cryogenic oven cooling with liquid N2, installation (44K), Hands-on-training at time of installa tion (44L), verify system performance (44U), 1 each; c) #H5901A, Instrument Performance Verif. Tests of discrete subsystem components and integrated testing of complete instrument. Documented test results. Requires appropriate option. GC OQ/PV second c hannel, 2 each; d) #G2613A, 7683 Autoinjector module, includes three-and eight-sample turrets, 2ml sample vials, 4ml solvent wash and waste bottles, syringe and small ?parking? post for the top of the GC, installation (44K) Hands-on-training at time of in stallation (44L), 4 each; e) #G2614A, 7683 Autosampler tray module. Includes a pack of 100 2-mL screw-cap vials. Provides cable connection for the G1926A bar code reader, installation (44K), Hands-on-training at time of installation (44L), 2 each; f) # G2705AA, High end PC Bundle. Includes CPU, Monitor, CD-ROM, Printer, Windows, delete 1 Monitor, delete 1 Printer, installation (44K), performance testing and certification of standards (44V) verify system performance (44U), 1 each; g) #G2071AA, ChemStatio n software for additional GC. Software module to add control of and data acquisition from an additional Aglient GC and 7673 or 7683 autosampler, installation (44K) Hands-on training at time of installation (44L), performance testing and certification of st andards (44V), verify system performance (44U), 1 each; h) #G2183AA, ChemStation Plus Security Pack, Adds the secure ChemStore relational database software module to the ChemStation Plus SW for A/D, GC, CE, LC and CE/LC-MSD. Supports 21 CFR part 11, inst allation (44K), Hands-on training at time of installation (44L), performance testing and certification of standards (44V), verify system performance (44U), Software support (44W), 1 each; i) #H5949A, Supplemental Installation One Hour Labor for Chemical An alysis products. Labor only; no travel included. Requires installation ? bundles, or as 44N or 44K, 4 each; j) #G1570A, Three channels of auxiliary EPC. Three channels of auxiliary 0-100 psi EPC, installation (44K), 1 each; k) #GC95700-00, Container for l iquid nitrogen, 1 each; l) #D7522B, HP 3COM 10/100BT PCI NIC, 1 each; m) #D8911A, HP 91 19? flat CRT monitor, 1 each; n) #J3294A, HP Procurve 10/100 Hub 12 auto sensing, 1 each; o) #C8049A, HP LasterJet 4100, 1 each; p) #C2950A, Parallel interface cable, 1 each; q) Compressor Type 6000M ? 150, 1 each; r) Zero Air Generator, Flow: 500ml/min, Pressure: 5bar; compression air: ca. 7bar, 1 each; s) Complete installatio n of system; t) MUST BE ABLE TO PROVIDE SUPPORT MAINTENANCE, REPAIRS, SERVICE ON CUSTOMER SITE WITH A MAXIMUM REACTION TIME OF 24 hours; u) All cable, transfer lines and communication lines shall be included; v) Shall include U.S. Keyboard; w) Shall includ e paper tray for 8.5? x 11? paper for printer; x) All equipment shall be configured to operate at 220V/50hZ single phase power; y) Shall include HP-IB interface card; z) 1 year software support and updates, standard commercial warranty; aa.) Standard Comm ercial Warranty; bb) Operator?s Manuals: 4 each in English, 1 each in German; cc) Maintenance Manuals: 3 each in English, 1 each in German; and dd) Direct delivery to customer site in Germany. Requisition Numbers W23MWP21280005. Acceptance shall be at Destination. Shipping shall be FOB Destination. Period is performance is 2 months. Delivery shall be to Kirchberg Kaserne, Germany. The provision at 52.212-1, Instructions to Offerors--Commercial, applies to this acquisition. The provision at 52.212- 2, Evaluation--Commercial Items applies to this acquisition; fill-ins in Paragraph (a) are ?Price and Past Performance? and ?less important than price?. A completed copy of the provision at 52.212-3, Offeror Representations and Certifications--Commercial I tems, must be provided with offers. The clause at 52.212-4, Contract Terms and Conditions--Commercial Items, applies to this acquisition. The clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders--Commercial I tems, applies to this acquisition. Additional FAR clauses cited in this clause are applicable: (1) 52.203-6, Restrictions on Subcontractor Sales to the Government, with Alternate I (41 U.S.C. 253g and 10 U.S.C. 2402), (2) 52.219-4, Notice of Price Evaluati on Preference for HUBZone Small Business Concerns (Jan 1999) (if the offeror elects to waive the preference, it shall so indicate in its offer), (3) 52.219-8, Utilization of Small Business Concerns (15 U.S.C. 637 (d)(2) and (3)), (4) 52.222-21 Prohibition of Segregated Facilities (Feb 1999), (5) 52.222-26 Equal Opportunity, (6) 52.222-35 Affirmative Action For Disabled Veterans and Veterans of the Vietnam Era, (7) 52.222-36 Affirmative Action For Workers with Disabilities, (8) 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era (38 U.S.C. 4212), (9) 52.222-19, Child Labor--Cooperation with Authorities and Remedies (E.O. 13126), (10) 52.232-33, Payment by Electronic Funds Transfer-Central Contractor Registration (May 1999), and (11) 252.204-7004 Required Central Contractor Registration. The full text of the FAR references may be accessed electronically at this address: http://farsite.hill.af.mil. Responses to this RFQ must be signed, dated, and received via electronic mail or fax by 12 June 2002 no later than 9:00 AM EST at the Robert Morris Acquisition Center, AMSSB-ACC-AT (Kathleen Wissler), 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013. Vendors who are not registered in the Central Contractor Registration (CCR ) database prior to award will not be considered. Vendors may register with CCR by calling 1-800-334-3414 or by registering online at www.ccr.gov. For questions concerning this solicitation contact Kathleen Wissler, Contracting Officer, at (410) 278-0891, fax (410) 278-0900, or email Kathleen.Wissler@sbccom.apgea.army.mil.
 
Place of Performance
Address: US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch ATTN: AMSSB-ACC-A, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
Zip Code: 21005-3013
Country: US
 
Record
SN00084723-W 20020531/020529213301 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.