Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 26, 2002 FBO #0206
SOLICITATION NOTICE

66 -- 66-Instrument laboratory equipment

Notice Date
6/24/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Treasury, Bureau of Alcohol, Tobacco and Firearms (ATF), Acquisition and Property Management Division, 650 Massachusetts Avenue, N.W., Room 3290, Washington, DC, 20226
 
ZIP Code
20226
 
Solicitation Number
2301-023
 
Response Due
7/2/2002
 
Archive Date
7/17/2002
 
Point of Contact
Angel Matthews-Warren, Contract Specialist, Phone (202) 927-8685`, Fax (202) 927-8688, - April Lowe, Sup. Contract Specialist, Phone (202) 927-7718, Fax (202) 927-2986,
 
E-Mail Address
acmatthews@atfhq.atf.treas.gov, aalowe@atfhq.atf.treas.gov
 
Small Business Set-Aside
Very Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation document and all incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-27. Requirement is for the purchase of laboratory equipment and support services. The following provisions are applicable to this acquisition: (a) FAR 52.212-1, Instructions to Offerors-Commercial, (b) FAR 52.212-4, Contract Terms and Conditions-Commercial Items, (c) FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items. The provision at FAR 51.212-2 Evaluation-Commercial Items applies to this acquisition The following items are to be procured on a firm fixed price contract. The Bureau of Alcohol, Tobacco and Firearms (ATF) has a requirement for the MVC-5000 New High Capacity, Controlled Environment, Superglue Fuming Chamber for Rifles, Shotguns and Large pieces of evidence for processing. This requirement must be manufactured by Foster+Freeman USA, INC, located 1333 Swan Drive, Annapolis, Maryland, 21401. ABSOLUTELY NO SUBSTITUES WILL BE ACCEPTED. Shipping, Handling, Set-up and 2 Day Training Included. Unit is supplied with a basic power supply with separate item for upgrade to UPS power supply. SPECIFICATIONS are as follows: The cabinet is capable of providing a treatment environment isolated from the laboratory, complete with an internal activated carbon based self cleaning system. Maximum size safety glass windows to provide good all round visibility; External dimensions: height 2240mm, width 1520mm, depth 900mm (88 x 60 x 34 inches); Internal dimensions: height 2100mm, width 1410mm, depth 630mm, (83 x 56 x 25 inches); Door aperture: height 2060mm, width 760mm, (81 x 30 inches); Internal Volume: 1.87 cubic metres, Power supply unit (basic); input 110 or 230V (specify at time of order), output to cabinet 500W, 24V Displays: chamber temperature, humidity & status of cycle, Internal air circulation, fan assisted, uniformity of temperature, humidity, Operating modes; manual and automatic, Humidity level; preset to 80%RH, accuracy of better than 5%RH in the temperature. REQUIRED: range 15 to 25C; Cyanoacrylate evaporation temperature: 120 deg.C (preset); Cyanoacrylate fume exposure (auto mode): programmable 10 to 99mins, default setting is 15 mins; Cyanoacrylate fume cleansing: up to 40 mins; Filter (active ingredient): activated carbon, replaceable; Filter (active ingredienct): activated carbon, replaceable, Filter lifetime: minimum of 80 cleansing cycles loaded with up to 10g of cyanoacrylate per cycle; Residual internal fume concentration (post 40 min clean): less than 0.3ppm ( the occupational exposure standard for ethyl cyanoacrylate): Shelving; the cabinet has a rigid base with rails and modular shelving which can be located in various positions to suspend or support exhibits as required. Several full-sized standard doors or car seats can be accommodated if required. Access: loading of articles and replacing consumable items is achieved without entering the chamber; Installation: the cabinet is constructed in modular form to ensure that it passes through a single door width of 750mm. Installation by Mason Upgrade to UPS power supply unit for MVC-5000 or MVC-3000; input 110 or 230V (specify at time or order); output to cabinet 500W, 24V; capable of supporting a complete machine cycle if mains input power fails, internal batteries: 2 x 24AH 12V seal lead-acid batteries, On-site assembly, installation and training by Foster+Freeman USA, Inc. personnel. The vendor must also submit certification of compliance with Section 508 of the Rehabilitation Act of 1973. Awardee must complete the SF-3381 ACH Vendor/Miscellaneous Payment Enrollment Form, and be registered by the Central Contractor Register by the closing date of this announcement. Quotes must include delivered price and product literature, which lists specifications. Award will be based on meeting the technical specifications listed above, on an ALL OR NONE basis. Questions concerning this procurement should be addressed by fax to Angel C. Matthews-Warren, Contracting Officer, (202) 927-8688. All interested parties must submit a quote by 5:00 p.m. EST July 2, 2002.
 
Place of Performance
Address: Rockville, Maryland 20850
 
Record
SN00098713-W 20020626/020624213348 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.