Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 30, 2002 FBO #0210
SOLICITATION NOTICE

49 -- Combination power Maintenance Unit

Notice Date
6/28/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Air Force, Air Combat Command, 99 CONS, 5865 Swaab Blvd, Nellis AFB, NV, 89191-7063
 
ZIP Code
89191-7063
 
Solicitation Number
F26600-02-Q-A055
 
Response Due
7/15/2002
 
Archive Date
7/30/2002
 
Point of Contact
Kristen Gordon, Contract Specialist, Phone 702-652-5321, Fax 702-652-9570, - George Dowdey, Contract Specialist, Phone 702-652-2099, Fax 702-652-9570,
 
E-Mail Address
kristen.gordon@nellis.af.mil, george.dowdey@nellis.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation: quotations are being requested and a written solicitation will not be issued. This solicitation F26600-01-Q-A055 is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Regulation (FAR) 12 and 13. This is 100% reserved for small business. The Standard Industry Classification (SIC) for this solicitation is 3569 and the North American Industry Classification System (NAICS) is 333999. Based on Standard Size 500 employees. The item description is as follows: CLIN 0001- one (1) EA, Combination Power Maintenance Unit with simultaneous Welder, Air Compressor, Electricity, Light Tower, Battery Charge and Jumper functions, trailer tongued assembly mounted. The Combination Unit shall have a steel constructed, acoustical foam insulated combination cabin which is trailer/tongue assembly mounted. The trailer/tongue assembly will have a pintle hook with 6? height adjustment. The trailer shall have electric brakes, a minimum axle capacity of 5200lbs, two (2) leveling jacks, and a minimum tire size of 225 x 15. The combination cabin shall include: one (1) Welder with the following specifications: minimum of 400 Amperes, high frequency converter power, constant power out put, multi-process capability, auto hot start, carbon arc transfer stick, MIG short arc/spray, stud and TIG Gouging, a minimum range selection of 100-180 and 180-400, and Panel and Remote power control; one (1) Air Compressor with the following specifications: (wet) twin screw, 185 CFM, 90-150 PSI, dual on/off receptacles, compressor on/off electric clutch, drive via poly chain drive, coalesler oil separation, minimum quick drain valve oil capacity of 4.8 U.S. Gallons/18 Liters; one (1) Engine with the following specifications: minimum of 107 HP (Derated to 88 HP), minimum oil capacity of 9 Quarts/8.5 Liters, CD classification oil grade, minimum Coolant Capacity of 2 U.S. Gallons/7.6 Liters, Residential Muffler, minimum Fuel capacity of 50 U.S. Gallons/196 Liters, minimum 10-15 Hours continuous run, quick drain valve engine oil change, fuel filter with drain, and air filter; one (1) Generator with the following specifications: 20 KW Continuous/28 mhp., 25 KW Standby/34.9 mhp., and simultaneous power available with 120V/1phase, 240V/3phase, 50 or 60 cycle 480V/3phase, direct drive to engine, power receptacles (all voltages, circuit breaker protection (all voltages), and frequency (all voltages); and two (2) Adjustable, Roof-Mounted Light Towers with the following specifications: each Tower shall support a minimum of two (2) 120VDC minimum halogen or two (2) 500 Watt AC minimum light fixtures, each Tower shall have maximum stowed dimensions of 32? x 26.5? x 9?, a maximum extended height of 32?, full rotation and tilt by remote control, full erection time shall be a minimum of 6 seconds, a minimum wind capacity of 65 m.p.h., and each tower weight shall be a maximum of 51lbs. The Combination cabin shall include an instrument panel mounted on the front of the cabin with separate meters, circuit breakers, and receptacles for the Welder, Air Compressor, Engine, and Generator. The Combination cabin shall include Automatic Safety Shut Down accessible from the instrument panel for low engine oil pressure, high engine coolant temperature, high cabin temperature, and high compressor oil temperature. The Combination cabin shall also have a minimum of six (6) emergency flashers, one (1) 25? Remote Weld Power Cable with weld leads, one (1) 50? Air Hose, one (1) set of 15?12 V Jumper Cables, one (1) 12V Trouble Light, and one (1) fire extinguisher. CLIN 0002 ? Plasma Cutter, one (1) EA, with the following specifications: a minimum output of 15-60 amps continuously variable, minimum input power of 208-230 V, 1 phase, 50/60 Hz, 61/56 amps, 460 V, 3 Phase, 50/60 Hz, 18 amps, minimum duty cycle of 40%, panel controls with on/off and output amps, and panel indicators with AC power and temperature. The Plasma Cutter shall have a minimum height of 16?, a minimum width of 10?, a minimum length of 20?, a minimum weight of 72lbs, and a minimum cut capacity of 7/8?, 1.25 severance. The unit shall have a torch of PCH-76, gas Air/N2, minimum gas pressure of 60 psi, minimum gas flow of 3000SCFH, torch mounted control switch, minimum torch configuration of 70 degrees or 90 degrees, and a minimum lead length of 20ft/ 50ft. Delivery date is 30 September 2002, place of delivery and FOB point is 555th Red Horse Squadron, 8230 Bergstrom Ave. Nellis AFB, NV 89191. The entire solicitation including, Offerors Representations and Certifications, Attachment 1, and Past Performance Evaluation Questionnaire, Attachment 2 will be released on the Federal Government Electronic Posting Systems (EPS) site, http://eps.satx.disa.mil/. Amendments will be posted on the affected solicitation page EPS site. It is the offeror?s responsibility to monitor this site for the release of amendments (if any). The following provisions and clauses can be viewed through Internet access at Air Force FAR Site, http://farsite.hill.af.mil. The following clauses and/or provisions apply to this solicitation: FAR 52.212-1, Instructions to Offerors ? Commercial Items, with the following technical description in sufficient detail to evaluate compliance with the requirements of the solicitation (i.e. product literature), the terms of any expressed warranty, price and any discount, and delivery times; FAR 52.212-2 Evaluation ?Commercial Items. Award will be made to the responsible, responsive offeror whose offer will result in the best value to the government, technical specifications, price and past performance considered. The provisions at 52.212-3, Offeror Representation and Certifications?Commercial Items, 52.212-4, Contract Terms and Conditions-Commercial Items applies to this solicitation. 52.212-5, Executive Orders-Commercial Items, 52.225-13, Restrictions on Certain Foreign Purchases, 52.225-15, Sanctioned European Union Country End Products, 52.222-19, Child Labor- Cooperation with Authorities and Remedies, and 52.232-33, Payment by Electronic Funds Transfer?Central Contractor Registration applies for this solicitation. The provisions at 52.252-2, Clauses Incorporated by Reference apply to this solicitation. The provisions at 252.225-7000, Buy American Act- Balance of Payments Program Certificate, 252.204-7004, Required Central Contractor Registration. Offerors must include with their quotations: Technical data and drawings for Clin 0001, the Combination Power Maintenance Unit along with a completed copy of the provisions at 52.212-3, Offeror Representations and Certifications--Commercial Items, Attachment 1 and Past Performance References, a minimum of (3) three, Attachment 2. Offerors who fail to complete and submit Specifications data and drawings, Representations and Certifications and Past Performance References, a minimum of three, may be considered non-responsive. For solicitations issued after 1 Jun 98 all ** contractors are required to Registered in the Central Contractors Registration (CCR) **. If not already registered, you should immediately register with CCR by calling 1-888-227-2423 or via the Internet at http://www.ccr2000.com. Contractors are required to have a Dun & Bradstreet number (DUNS) in order to be registered in the CCR database. Lack of registration prior to award, may make an offeror ineligible for award. A contractor can receive a DUNS number by calling Dun & Bradstreet at (800) 333-0505. Internet registration takes approximately 72 hours: mail-in registration takes approximately 30 days. Interested parties must submit any questions in writing to the Contracting Officer listed below, by fax or email. Quotations and amendments (if any) must be signed, dated and submitted in writing or by fax by 2:00 PM on 15 July 2002 Pacific Standard time to the 99th Contracting Squadron, 5865 Swaab Blvd., Nellis AFB, NV 89191, Attention Kristen C. Gordon. Contact Contracting Specialist Kristen C.Gordon at (702) 652-5321, FAX NO. (702) 652-9570, and Kristen.Gordon@nellis.af.mil or Contracting Officer George D. Dowdey at george.dowdey@nellis.af.mil and (702) 652-2099 for information regarding this solicitation.
 
Place of Performance
Address: 8230 Bergstrom Ave., Bldg. 10210, Nellis AFB, NV
Zip Code: 89191
Country: USA
 
Record
SN00101526-W 20020630/020628213203 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers