SOLICITATION NOTICE
66 -- ENVIRONMENTAL TEMPERATURE CHAMBER
- Notice Date
- 8/27/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- Department of Commerce, National Oceanic and Atmospheric Administration (NOAA), National Data Buoy Center, National Data Buoy Center Building 1100, Room 360F, Stennis Space Center, MS, 39529-6000
- ZIP Code
- 39529-6000
- Solicitation Number
- QA1330-02-RQ-02-0030
- Response Due
- 9/12/2002
- Archive Date
- 9/27/2002
- Point of Contact
- Dennis Morris, Contract Specialist, Phone 228-688-1706, Fax 228-688-3153, - Penny Parker, Contracting Officer, Phone 228-688-1705, Fax 228-688-3153,
- E-Mail Address
-
dennis.morris@noaa.gov, Penny.Parker@noaa.gov
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined commercial item synopsis/solicitation prepared in accordance with the format in the Federal Acquisition Regulations (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This announcement is a request for quote. The solicitation number is QA1330-02-RQ-02-0030 and incorporates provisions and clauses in effect through Federal Acquisition Circular (FAC) 2001-8. The contract will be a firm-fixed price order. The National Data Buoy Center (NDBC) Stennis Space Center, MS 39529 intends to purchase two environmental temperature chambers. The description of the unit is as follows: ENVIRONMENTAL TEMPERATURE CHAMBER(REACH-IN TYPE) FOR THE NDBC TESTING LABORATORY; MINIMUM REQUIREMENTS - TEST VOLUME SIZE 3FT X 3FT X 3FT(NOMINAL); TEMPERATURE RANGE - 60 DEGREES C TO +170 DEGREES C (OR GREATER); CONTROL TOLERANCE - +/- 0.5 DEGREES C OR BETTER AFTER STABILIZATION AT SET POINT; HEATING PERFORMANCE: AMBIENT(+23 DEGREES C) TO 90 DEGREES C IN 20 MINUTES OR FASTER(EMPTY CHAMBER, NO LIVE LOAD); COOLING PERFORMANCE: AMBIENT(+23 DEGREES C) TO -50 DEGREES C IN 20 MINUTES OR FASTER(EMPTY CHAMBER, NO LIVE LOAD); WORKSPACE INTERIOR DIMENSIONS: 36"W X 36"H X 36"D MINIMUM SIZE; TEMPERATURE UNIFORMITY: +/-0.7 DEGREES C; HUMIDITY CONTROL: NONE REQUIRED; INSTRUMENTATION: PROGRAMMABLE CONTROLLER WITH SET POINT AND TEMPERATURE PROFILE SELECTION - RS-232 COMMUNICATION(OR RS-422 OR RS-485); ELECTRICAL POWER: 230 VOLTS, 3 PHASE, 60 Hz(MAIN POWER DISCONNECT SWITCH REQUIRED); INTERIOR: 300 SERIES STAINLESS STEEL - HERMETIC SEAL CONSTRUCTION; EXTERIOR: HEAVY-GAUGE COLD ROLLED STEEL WITH ENAMEL PAINT PROTECTION - SEAMS SEALED TO PREVENT MOISTURE MIGRATION; PRODUCT SAFEGUARD: PRECISION ADJUSTABLE HIGH AND LOW TEMPERATURE SETTING FOR EMERGENCY CHAMBER SHUTDOWN(WITH AUDIBLE ALARM); OVER TEMPERATURE SAFETY: FACTORY SET FOR NOT EXCEEDING CHAMBER DESIGN LIMITS; REFRIGERATION SYSTEM: AIR COOLED-CFC-FREE REFRIGERANT, CAPABLE OF OPERATION INSIDE AN AIR CONDITIONED LABORATORY AREA(23 DEGREES C, 50% RH); LIVE LOAD CAPACITY: -40 DEGREES C, 800 WATT OR GREATER; ACCESS PORT: TWO 4" DIAMETER PORTS THROUGH RH SIDE WALL(WITH COVERS); THERMAL INSULATION: ASBESTOS FREE; FLOOR SUPPORT: STEEL CASTERS; GAUGES: REFRIGERANT PRESSURE GAUGES, EASILY ACCESSIBLE; INTERIOR LIGHTING: NONE REQUIRED UNLESS SUPPLIED WITH STANDARD CHAMBER DESIGN; INTERIOR SHELVING: NONE, BUT EASILY REMOVED IF SUPPLIED AS STANDARD; RECORDING INSTRUMENTS: NONE; VIEWING WINDOW: NONE REQUIRED UNLESS SUPPLIED WITH STANDARD CHAMBER DESIGN; MANUALS: COMPLETE SET OF OPERATION AND MAINTENANCE MANUALS THAT INCLUDE ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS, PARTS LIST, AND MAJOR COMPONENTS SPECIFICATIONS; FACTORY ACCEPTANCE: TEST OF CHAMBER AT THE FACTORY TO BE WITNESSED BY NATIONAL DATA BUOY CENTER REPRESENTATIVE. DETAILED DESCRIPTION OF ITEM OFFERED MUST BE INCLUDED WITH QUOTE. FOB DESTINATION TO STENNIS SPACE CENTER, MS; DELIVERY 60 DAYS AT RECEIPT OF ORDER; 100% SMALL BUSINESS SET-ASIDE. CLAUSES: The following FAR provisions or clauses apply to this acquisition: 52.212-1 Instructions to Offerors-Commercial; 52.212-2 Evaluation-Commercial Items, The Government will award a purchase order resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government. The following factors shall be used to evaluate offers: technical capability of the item offered to meet the Government requirement, price, small business participation; 52.212-3 Offeror Representations and Certifications-Commercial Items; 52.212-4 Contract Term and Conditions-Commercial Items; 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items; 52.222-21 Prohibition of Segregated Facilities; 52.222-26 Equal Opportunity; 52.222-35 Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-36 Affirmative Action for Workers with Disabilities; 52.222-19 Child Labor-Cooperation with Authorities and Remedies; 52.222-1 Buy American Act-Supplies; 52.225-3 Buy American Act-North American Free Trade Agreement-Israeli Trade Act; 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration. Quotes may be faxed to FAX #228-688-3153 Attn: Dennis Morris; or mailed to National Data Buoy Center, Attn: Dennis Morris, Building 1100 Room 360, Stennis Space Center MS 39529. Detailed description of item offered must be included with quote.
- Web Link
-
Link to FedBizOpps document.
(http://www.eps.gov/spg/DOC/NOAA/NDBC/QA1330-02-RQ-02-0030/listing.html)
- Place of Performance
- Address: National Data Buoy Center Building 1100 Stennis Space Center, MS
- Zip Code: 39529
- Country: USA
- Zip Code: 39529
- Record
- SN00151639-F 20020829/020827221251 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |