SOLICITATION NOTICE
65 -- 65-STRYKER NAVIGATION SYSTEM
- Notice Date
- 12/6/2002
- Notice Type
- Solicitation Notice
- Contracting Office
- Attn: Department of Veterans Affairs Medical Center, Contracting Officer, (90C), 800 Irving Avenue, Syracuse, New York 13210-2799
- ZIP Code
- 13210-2799
- Solicitation Number
- 528A7-09-03
- Archive Date
- 1/18/2003
- Point of Contact
- Point of Contact - Dana Ivey, Contracting Officer, (315) 425-4845, Contracting Officer - Dana Ivey, Contracting Officer, (315) 425-4845
- E-Mail Address
-
Email your questions to Dana Ivey
(dana.ivey@med.va.gov)
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The North American Industry Classification System (NAICS) Code applicable to this solicitation is 421450, Medical, Dental and Hospital Equipment and Supplies Wholesalers, and the small business size standard is 100 employees. This is a full and open competition (unrestricted). The VA Healthcare Network Upstate New York at Syracuse, NY intends to purchase a Stryker Navigation System, brand name or equal. Mfg: Leibinger. The components are One (1) Stryker Navigation System. One (1) Cart System, item number 6000000; One (1) Neuro Software Package, item number 6000600000; One (1) Spine Windows Software Spine Applications, item number 6002600000; One (1) Flour Navigation Software and Hardware Package, item number 6004600000; One (1) Hardware Kit OEC 9800 & 9600 9_, item number 6004002000; One (1) Media Drive Maxoptics, item number 6000110011; One (1) Media Drive, HP Dat, Item number 6000110031; One (1) Tracker to Mayfield Adapter, item number 600000700; Two (2) Universal Tracker, item number 600000500; Two (2) Long Pointer, item number 600001100; One (1) Short Pointer, item number 600001200; One (1) Point Calibration Device, item number 6000010000; One (1) Patient Tracker Support, item number 6001100100; One (1) Forehead Pad, item number 6001100200; One (1) Head Strap, item number 6001100300; Ten (10) Instrument Battery, item number 6000006000; One (1) Pointer (R. Post-Fossa), item number 6001022000; One (1) Suction Tube (2.7mm, R. Post-Fossa), item number 6001088227; One (1) Large Universal Adapter, item number 6000015000; One (1) Spine Tracker, item number 6002005000; One (1) Spine Clamp, item number 6002016000; One (1) Straight Gear Shift, item number 6002300000; One (1) AWL, item number 6002700000; One (1) Revision Pin 12mm, item number 6002017012; One (1) Revision Pin 18mm, item number 6002017018; One (1) Calibration Tool, item number 6000009000; One Sterilization Rack, Calibration Tool, item number 6000009090; One (1) Sterilization Container, Calibration Tool, item number 6000009012; One (1) Frameless Guide, item number 6000022000; Five (5) FGS Screw, 2.0x8mm, x-fit, self tapping, item number 8103402; Five (5) Bone Screws, Cross Fit, Self Tapping, 2.0x4mm, item number 5220704; Five (5) Emergency Screw, 2.3mm x 4.5mm, Self Tapping, item number 8103403; 2.0mm Burr Hole Covers 10mm Burr Holes, item number 5406192; One (1) Screwdriver Blade, Slot Pin, Dental, item number 8103404; One (1) 2.0mm Screwdriver Blade, cross fit, for metal handle 6200534, item number 6223002; One (1) FGS Drill bit, 1.5mm dental, item number 8103405; Three (3) Screwdriver Handle, metal, 10.5cm, item number 6200160; One (1) FGS Side Cutting Biopsy Probe, item number 8103700; One (1) Sterilization Container, FGS Accessories, item number 8103902; Two (2) Cart System Year extended warranty, item number 6000115000W; Two (2) Neuro Software Year Extended Warranty, item number 6000600000W; Two (2) Spine Software Year extended warranty, Item number 6002600000W; Two (2) Flour Windows Software Extended warranty, item number 6004600000W; One (1) Technical Assistance Fee. Salient characteristics of the equipment include: (1)Windows based. Allows for expansion/installation of new programs, maintenance and on-site troubleshooting. (2) Windows based software to include the following: 3-D modeling of CT, MRI, Angio, and PRT Images; Schettenbrandt Atlas; Talarch Atlas; Functional planning software with Atlas correlation_s; Guidance mode for trajectory planning, Predefined user screens as well as user defined screens. Automatic features to provide: Contouring, Fiducial localization; Instrument identification; Tool calibration (Hand pieces must have capacity to be recalibrated in house if damaged or bent.); Multiple stereo tactic frame support for ZD, CRW, Leksell. DICOM compatible. (3) DICOM capable and VISTA Imaging compatible. (4) Wireless Active LED System. Wireless hand-pieces to allow the surgeon to solely control all features and functions. Instruments are to have a built in mouse which allows the surgeon complete control during the case vs. having to rely on an OR staff member to operate the software for them. Hand pieces are to be Autoclavable. (5) The navigation system will fully integrate with ancillary diagnostic scanning functions (CT, MRI, Angio, PET, etc.) regardless of the make, model or manufacturer of the diagnostic equipment. (6) All proposed components and configurations must be FDA approved. This solicitation document incorporates Federal Acquisition Regulation (FAR) provisions and clauses in effect through Federal Acquisition Circular 01-10 and VA Acquisition Regulation (VAAR) clauses as follows: 52.211-6 Brand Name or Equal; 52.212-1 Instructions to Offerors Commercial Items; 52.212-3 Offeror Representations and Certifications _ Commercial Items; 52.212-4 Contract Terms and Conditions _ Commercial Items; 52-212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items with (b)(11), (12), (13), (14), (15), (16), (18), (21), and (25) checked; and VAAR 852.270-4 Commercial Advertising. Offers to include completed copy of 52.212-3 Offeror Representations and Certifications _ Commercial Items. The provision at 52.212-2, Evaluation of Commercial Items, applies to this acquisition. The evaluation criteria stated in paragraph (a) of this provision is as follows. (1) Technical capability of the item offered to meet the government requirement and (2) price. The system offered must meet all the salient characteristics specified above to be considered for award. Award will be made to the offeror proposing an acceptable system at the lowest overall price. FAR and VAAR may be accessed electronically at http://www.arnet.gov/far and http://www.va.gov/oa&mm/vaar. Address offers to Contracting Officer (2-90NCA), VA Medical Center, 800 Irving Avenue, Syracuse, NY 13210 and reference solicitation number. EmailaddDana.Ivey@med.va.gov
- Web Link
-
RFP 528A7-09-03
(http://www.bos.oamm.va.gov/solicitation?number=528A7-09-03)
- Record
- SN00218205-W 20021208/021206213421 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)