SOURCES SOUGHT

34 -- Batch-Type Convection-type curing oven, spray booth, and burn-off oven as part of a powder coating spray system

Notice Date
12/13/2002
 
Notice Type
Sources Sought
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Lakehurst, Contracts Department Hwy. 547 Attn:B129-2, Lakehurst, NJ, 08733-5083
 
ZIP Code
08733-5083
 
Solicitation Number
N68335-03-RFI-0030
 
Response Due
12/31/2002
 
Archive Date
1/15/2003
 
Point of Contact
Joyce Discenza, Contract Specialist, Phone 732-323-2148, Fax 732-323-4822, - Daniel McClure, Contracting Officer, Phone 732-323-2801, Fax 732-323-2359,
 
E-Mail Address
joyce.discenza@navy.mil, daniel.mcclure@navy.mil
 
Description
This is a request for information only. There is no solicitation package available. TheNaval air Warfare Center Aircraft Division Lakehurst is seeking sources that may be capable of providing a batch-type convection-type curing oven, spray booth, and burn-off oven as part of a powder coating spray system. General requirements are as follows. The convection-type curing oven shall be a batch style oven with double doors designed for an operating temperature of 130 to 500oF. Specifically, the unit shall be used for the curing of thermosetting powder coatings. The overall dimensions of the oven defined below must not exceed the dimensions defined below. The entire unit including all appurtenances should be designed to fit into either (a) or (b): (a) 24' l x 14' w x 12' h; (b) 19.5' l x 14' w x 13.5' h. If ovens are to be designed to fit into space (a), booths must be designed to fit into space (b) or vice versa. Minimum interior dimensions should be 17' l x 10' w. Steel girders limit building interior height to between 12' at 2'6" from wall and 15'6" at 8'6" from wall. All pieces of the unit shall be designed to fit through either a 12' w x 13' h or 12' w x 18' h opening prior to assembly. The powder coating spray booth is a self-contained work environment including lighting, dust collection apparatus, and electrical control panel. Specifically, the unit shall be used for the batch, short-run, or special thermoset powder coating application of aircraft ground support equipment. The overall dimensions of the booth including all space required for maneuverability, safety, installation and satisfaction of NFPA requirements defined below must not exceed the dimensions defined below. The entire unit including all appurtenances should be designed to fit into either (a) or (b): (a) 24' l x 14' w x 12' h; (b) 19.5' l x 14' w x 13.5' h. If ovens are to be designed to fit into space (a), booths must be designed to fit into space (b) or vice versa. Minimum interior dimensions should be 17' l x 10' w. Steel girders limit building interior height to between 12' at 2'6" from wall and 15'6" at 8'6" from wall. All pieces of the unit shall be designed to fit through either a 12' w x 13' h or 12' w x 18' h opening prior to assembly. The burn-off oven should provide a temperature range of 750-800oF and produce very low emissions to meet CA standards. It should have a minimum afterburner T of 1400oF measured at the ? second point of the afterburner. The overall dimensions of the oven defined below must not exceed the dimensions defined below. The entire unit including all appurtenances should be designed to fit into a 21' l x 15' w x 12' h area. Minimum interior dimensions should be 15' l x 12' w x 10' h. Steel girders limit building interior height to between 12' at 2'6" from wall and 15'6" at 8'6" from wall. All pieces of the unit shall be designed to fit through either a 12' w x 13' h or 12' w x 18' h opening prior to assembly. It is expected that the electrical requirement shall be for 460V, 3 ph power. The ovens are required to use <1 mil BTU/hr. Please discuss the utility requirements of your equipment if they deviate from these figures. Brochure type photos would be helpful, as well as an approximate price and General Service Administration (GSA) availability. The Government will not pay for any information received in response to this request nor will the Government compensate any respondent for any costs incurred in developing the information provided to the Government. Responses should cite the RFI Number N68335-03-RFI-0030 and be addressed to the attention of Mrs. Joyce Discenza, Code 25222JD, Hwy. 547, Bldg. 562-1, Naval Air Warfare Center Aircraft Division Lakehurst, N.J. 08733-5104. All responses are due by 31 December 2002.
 
Record
SN00223417-W 20021215/021213213833 (fbodaily.com)
 