SOLICITATION NOTICE
49 -- Media Blast Room, Self-Contained Modular Media Blast Room Ventilated and Illuminated for Enclosed Abrasive Blasting
- Notice Date
- 1/10/2003
- Notice Type
- Solicitation Notice
- Contracting Office
- USPFO for Mississippi, 144 Military Drive, Jackson, MS 39208-8860
- ZIP Code
- 39208-8860
- Solicitation Number
- DAHA22-03-T-0009
- Archive Date
- 3/29/2003
- Point of Contact
- Jerri Winfield, 601-313-1565
- E-Mail Address
-
Email your questions to USPFO for Mississippi
(jerri.winfield@ms.ngb.army.mil)
- Small Business Set-Aside
- N/A
- Description
- NA This is a combined synopsis/solicitation for commercial item prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in the notice. This announcement constitutes the only solicitation; Request for Qu otes are being requested and a written solicitation will not be issued. Solicitation No. DAHA22-03-T-0009 applies and is issued as a Request for Quotation. This document and incorporated provisions and clauses are those in effect through Federal Acquisit ion Circular 2001-09. The North American Industry Classification System (NAICS) code is 332311 size standard is 500 employees. The following items are intended to be purchased for the Government: Item # 1. Furnish and Install Self-Contained Modular Media Blast Room Ventilated and Illuminated for Enclosed Abrasive Blasting. Maximum Exterior Working Dimensions: 15?-6? W x 15?-6?H x 20?-6? L Maximum Interior Working Dimensions: 15?-0? W x 15?-0? H x 20?-0? L Minimum 10 gauge primed and painted wall panels and minimum 12 gauge ceiling panels, which are sealed and bolted together making a dust tight enclosure. Double doors will be furnished at one end of the room opening 12 to 15 feet wide x 15 feet high. Pers onnel door 2?-6? x 6?-8? with safety glass viewing window approximately 10? x 22?. All doors will be fitted with interlocks to prevent and stop blasting when any door is opened during operation. Flush mounted four (4) tubes, 48? fluorescent light assembl y fixtures will be furnished to illuminate the interior of the blast room with lighting requirements of 110 volts, single phase, 60 hertz. Full Floor Pneumatic Media Recovery System consisting of tube and hopper floor sections covered with screen and meta l grating (minimum rating at 1,000 lbs. per square foot). Cyclone separator (optional rubber lined) media reclaim system minimum rating 900 CFM powered by 5.0 horsepower (minimum) heavy-duty motor. High volume media storage hopper. One six (6) cubic fo ot capacity pressure vessel minimum rating of 125 PSI working pressure designed for plastic media, glass bead and aluminum oxide. Blast nozzle and hoses. Operator Remote Control is required. Dust Recovery Collector with blower and electric motor 20 HP, 220/480 volt, 3 phase, 60 Hz blower that will provide minimum 12,450 CFM volume. A 460-volt, 3 phase, 60 Hz pre-wired electrical control panel interlocked with the equipment doors and personnel door to prevent and stop blast operation if doors are opened. Operator safety equipment with Carbon Dioxide (CO2) monitor alarms and lights. Operator training and certification is required. Includes an external workstation for blasting smaller items and equipment. This is a ?Total Turn Key Job? and should be quo ted as such. Blue Prints of the booth quoted shall be furnished with quote. Point of Contact at for more information on this is MSGT. Charles Horne @ 601-936-8395. The following Federal Acquisition Regulations (FAR) and (DFARS) provisions apply to this solicitation: FAR 52.212-1, Instructions to Offerors-Commercial; FAR 52-212-2, Evaluation-Commercial Items (The following factors shall be used to evaluate offers: 1. Price, 2. Past Performance (submit three references of similar work), 3. Technical Quali fications, (submit technical data pertaining to equipment). Technical and past performance, when combined are approximately equal to cost or price); FAR 52-212-3, Offeror Representations and Certifications Commercial Items; FAR 52.212-5, Contract Terms a nd Conditions Required to Implement Statutes or Executive Orders Commercial Items; FAR 52.222.21 Prohibition of Segregated Facilities; FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era ; Far 52.222-36, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era; FAR 52.232-33, Payment by Electronic Funds Transfer Central Contractor Registration; FAR 52.232-34, Payment by Electronic Funds transfer other than Central Contractor Registration; FAR 52.232-36, Payment by Third Party; Far 52.239-1, Privacy or Security Safeguards; FAR 52.247-64, Preference for Privately Owned U.S. Flag Commercial vessels, FAR 52.252-2, Clauses Incorporated by Reference, DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisition of Commerci al Items, DFARS 252.204-7004, Required Central Contractor Registration, DFARS 252.225-7001, Buy American Act and Balance of Payment Program. Award can only be made to those offerors that are registered through the Central Contractor Registration System. For those not registered, you may log onto the Internet at http://www.ccr.gov or telephone (888) 227-2423. All offerors must include a completed copy of FAR 52.212-3, Offeror Representations and Certifications Commercial Items. Quotes are due no later th an 4:30 CST, January 28, 2003. Address quotes to USPFO-MS, Attn: NGMS-PFO-PC (Jerri Winfield), 144 Military Drive, Jackson, Mississippi 39232-8861. Quotes may be faxed to (601) 313-1569 to the attention of Jerri Winfield. Any questions may be directed to Jerri Winfield at: (601) 313-1565 or email at: jerri.winfield@ms.ngb.army.mil
- Place of Performance
- Address: 172nd Airlift Wing 141 Military Drive, Thompson Field Jackson MS
- Zip Code: 39208-8860
- Country: US
- Zip Code: 39208-8860
- Record
- SN00236988-W 20030112/030110213507 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |