Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 18, 2003 FBO #0412
SOLICITATION NOTICE

S -- Military Family Housing Maintenance, Bolling AFB, DC

Notice Date
5/31/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Air Force, Direct Reporting Units, 11th CONS, 110 Luke Avenue Building 5681, Bolling AFB, DC, 20332-0305
 
ZIP Code
20332-0305
 
Solicitation Number
F49642-02-R-0003
 
Response Due
6/30/2002
 
Point of Contact
Kelli Wright, Contract Administrator, Phone 2027677874, Fax 2027677896, - Willie Haney, Contract Specialist, Phone (202) 767-7980, Fax (202) 767-7816,
 
E-Mail Address
Kelli.Wright@bolling.af.mil, willie.haney@bolling.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
The 11th Contracting Squadron is seeking interested sources for the procurement of Multi-Discipline Indefinite Delivery Indefinite Quantity (IDIQ) Architectural Engineering (A-E) Services for the study and design of base construction projects. To meet this requirement, open-end contracts will be issued for one year with four one-year options. The contracts will have a maximum monetary limit of $750,000.00 per year for all years, with a minimum of $5,000.00 for the basic year. The initial delivery orders may not exceed $299,000.00. Four firms will be chosen through the selection process. 1. Each A-E firm must be qualified to work in one or all of the specified areas of discipline: a) Roofing/Waterproofing - A-E must have on staff, or access to, a Registered Roofing Consultant and Waterproofing Engineer/Specialist with expertise and experience in inspecting, evaluating and designing various roofing and waterproofing systems. Roofing systems include low-slope built-up, single-ply, modified bitumen and EPDM systems, as well as steep asphalt shingle, slate and metal roofing systems. A-E must have broad knowledge of, and familiarity with, a variety of moisture and air infiltration problems and have the capability of analyzing and addressing such problems. A-E must also be able to design roofing and waterproofing systems for general maintenance and repair construction. b) Civil/Structural - A-E must have on staff, or access to, a State Licensed Civil and Structural Engineer with expertise and experience in, geotechnical investigations/studies, foundation designs, topographical surveys, site and utility studies/designs, traffic studies, and environmental issues/designs. The A-E shall also have the capability of performing structural analysis/determinations on existing and new facilities of varying construction. c) Mechanical - A-E must have on staff, or access to, a State Licensed Mechanical Engineer with expertise and experience in a variety of heating, ventilating and air conditioning systems used on Bolling AFB, DC. DX expansion units, Chilled Water (CW), High Temperature Hot Water (HTHW), and Geothermal are some systems currently used. A-E must have experience with CW and HTHW systems at the plant and facility level. A-E must have experience in designing and trouble shooting of Direct Digital Control (DDC) energy management systems such as Siemens Controls and Honeywell. A-E must be able to perform in-depth analysis of existing systems to evaluate energy effectiveness of the system and give recommendations to increase energy efficiency. This applies to plant and facility levels. d) Electrical - A-E must have on staff, or access to, a State Licensed Electrical Engineer with expertise and experience in, investigating, studying and analyzing high, medium and low voltage distribution systems. A-E must be able to develop and define load demands on current base distribution systems as well as for individual buildings so that construction and repair projects can be developed to support a complete and adequate electrical distribution system, meeting all present and future demands. A-E shall be able to perform coordination studies, short circuit analysis, load demand calculations and overcurrent protection studies for the electrical distribution of the entire base or for a single facility. A-E must be familiar with both the radial and loop distribution systems, load shedding, daylighting, solar, wind and alternative technologies. e) Fire Protection - A-E must have on staff, or access to, a State Licensed Fire Protection Engineer with expertise and experience in, investigating, studying, analyzing and designing various fire detection, audio/visual annunciation and suppression systems used on Bolling AFB, DC. A-E shall have extensive knowledge of applicable codes, life-safety issues, and Federal requirements. 2. All interested A-E firms must have an on-call capability in their respective disciplines for response t NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (31-MAY-2002). IT ACTUALLY FIRST APPEARED ON THE FEDBIZOPPS SYSTEM ON 16-JAN-2003. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/USAF/DRU/11CONS/F49642-02-R-0003/listing.html)
 
Place of Performance
Address: Military Family Housing Bolling AFB, Washington DC
Zip Code: 20332-0305
Country: USA
 
Record
SN00241537-F 20030118/030116220807 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.