Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 30, 2003 FBO #0424
SOLICITATION NOTICE

43 -- Compressor/Dryer Systems

Notice Date
1/28/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AAC - Air Armament Center, AAC/PK 205 West D Avenue, Suite 433, Eglin AFB, FL, 32542-6864
 
ZIP Code
32542-6864
 
Solicitation Number
Reference-Number-TW50019523
 
Archive Date
2/26/2003
 
Point of Contact
Gwendolyn Quinn, Contract Specialist, Phone 850-882-0362, Fax 850-882-4916/1860, - Gregory Parry, Contracting Officer, Phone 850-882-0343, Fax 850-882-4916,
 
E-Mail Address
gwendolyn.quinn@eglin.af.mil, gregory.parry@eglin.af.mil
 
Description
The Air Armament Center (AAC), Eglin AFB, FL, intends to solicit and award Full and Open Competition Firm Fixed Price Purchased Order for AIR COMPRESSOR/DRYER SYSTEMS. This is a combined/solicitation for commercial items utilizing FAR 13.5, Test Program for certain Commercial Items and prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; a quotation is being requested, and a written request for quotation will not be issued. The reference number for this announcement is TW50019523. The North American Industry Classification System (NAICS) Code for this acquisition is 333912. The size standard for the NAICS code is 500 employees. If you feel your company meets the Government requirements, please identify your business size in your response based upon this standard. The requirement is as follows: Furnish two (2) COMPLETE AIR COMPRESSOR/DRYER SYSTEMS with, controls, drive motor, oil system, air system electronic pressure regulation system, cooling system, skid mounted, full enclosure for each compressor, and any other equipment necessary for operation. General requirements: All equipment shall be ready for operation after being connected to a 480 volt, 3 phase, 60 Hz power supply. The systems shall also meet the following minimum requirements. a) Each COMPRESSOR/DRYER SYSTEM shall be complete and capable of delivering a minimum of 500 SCFM to the air receivers at 195-PSIG delivery pressures. b) Air delivery shall be net and air production from the compressors shall be sufficient to allow for dryer requirements. c) Inlet design conditions are 94 degrees F., 14.5 PSIA and 57 % RH. d) Each unit shall be air-cooled e) All equipment shall be designed for outside installation in a salt air environment. f) Full enclosure shall be designed for outside installation and shall have weatherproof access for maintenance and shall include all shielding to protect the air inlet from water intrusion g) Each compressor system shall have the following minimum equipment 1) Two-stage high efficiency air inlet filter (3 micron or better) 2) Air inlet valve/un loader assembly 3) Gear drive with coupling or direct drive. 4) TEFC motors 5) ASME coded air/oil separator tank with pressure relief valve 6) High efficiency air/oil separator 7) Oil stop valve 8) Minimum pressure valve 9) Check valve 10) Oil cooler by-pass valve 11) Oil filter 12) Oil level indicator 13) After cooler 14) High efficiency moisture separator 15) Moisture separator automatic drain 16) Moisture separator manual drain 17) All starter and control transformers necessary for connection to 480 volt, 3 phases, 60 Hz power supply 18) Control system to be complete and automatic and maintain a 195-psig-supply pressure to the receivers 19) Any other equipment required for the full functioning of the air system 20) Maximum oil carryover 0.1 PPM 21) Anti condensation heaters for the oil system 22) The following minimum displays and indicators (a) Outlet temperature (b) Delivery air pressure (c) Air filter delta pressure (d) Oil separator delta pressure (e) High outlet temperature warning/shutdown indicator (f) Drive motor overload warning/shutdown indicator (g) Fan motor overload warning/shutdown indicator (h) Emergency stop warning/shutdown indicator (i) Air filter service indicator (j) Oil filter service indicator (k) Oil separator service indicator (l) Any other displays/indicators necessary for safe operation h) Each dryer system shall meet the following minimum requirements (1) Shall deliver air at full compressor flow to the receivers at -40 degrees F. dew point. 2) Shall be capable of drying air at required flow and at fully continuous operation 3) Complete with automatic controls 4) Skid mounted and suitable for outside installation in a salt air environment 5) All starter and control transformers necessary for connection to 480 volt, 3 phases, 60 Hz power supply. 6) The following minimum equipment (a) Pre filter (maximum .3 micron) (b) After filter (maximum 3 micron) (c) Auto drain (d) Differential pressure gauge (e) Sequence lights (f) Moisture indicator (g) Demand cycle control (h) Digital dew point monitor (i) High humidity alarm (j) Failure to switch alarm (k) Any other equipment needed for safe operation 7) The dryer shall be dual tower. Fully automatic regenerative type 8) The dryer shall be charged with desiccant 9) All pressure vessels shall have a minimum 1/16-inch corrosion allowance 10) the vessels shall have desiccant fill and drain ports. 11) All vessels shall have pressure relief valves as required by ASME code. i) Compressor enclosure and equipment finish 1) All components shall be free of grease, dirt and dust prior to 2) All weld spatters shall be removed prior to finishing 3) All bare metal surfaces shall be primed 4) All surfaces subject to rusting and all primed surfaces shall be finished with an epoxy enamel coating suitable for use in a salt air environment 5) Compressors shall be skid mounted and ready for placement on a concrete pad furnish by the government. 6) All equipment shall be contained in a permanent environmental enclosure suitable for a salt air environment with maintenance access provided by removable hinged covers with gaskets. 7) Gear or Direct Drive, 8) Equipment Spec sheets need to be provided for all major components, Compressor/Dryer, 9) No Belt Drive, 10) Need to address weather enclosure installation details, 11) Eglin will unload from vehicle, 12, Includes factory startup, one trip, both units. Additional information may be obtained from Mr. Dwayne Bell, 46 TW/TSWL, at (850) 882-4601. The solicitation and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2001-01. 52-212-3 Offeror Representations and Certifications- Commercial Items (Offerors must submit a complete copy with their offers. 52.212-4 Contract Terms and Conditions- Commercial Items; 52.212-5, Contract Terms and Conditions Required to Implement Statues or Executive Orders-Commercial Items (2/00), 52.212-5, sub-clauses that apply; 52.222-19, 52.222-21, 52.222-21, 52.222-26, 52.222-36, 52.222-37, 52.225-3 Alt I. Also clauses 52.232-33, Mandatory information for electronic Funds transfer payments; F.O.B Destination; 52.252-2, Clauses Incorporated By Reference; 52.252-6, Authorized Deviations; DFARS, 252.204-7004, Required Central Contractor Registration (CCR); 252.212-7001, Contract terms and conditions required to implement statues or Executive Orders applicable to Defense acquisitions of Commercial Items. To view the provisions and clauses in full text, visit the web site (farsite.hill.af.mil). The quote format is at the discretion of the offeror. If your company is capable of providing this item, qualification package should be received NLT 4:00 PM., Central Time on 11 February 2003. Anticipated award date is two day after the due date. Send all packages to AAC/PKOBS, Attn: Gwendolyn Quinn, 205 West D. Ave, Suite 541, Eglin AFB Florida, 32542-6862, or by facsimile to (850) 882-4916 or email at gwendolyn.quinn@eglin.af.mil or Gregory L. Parry gregory.parry@eglin.af.mil.
 
Record
SN00247871-W 20030130/030128213225 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.