Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 21, 2003 FBO #0446
MODIFICATION

93 -- Glovebox Polycarbonate Window Panels

Notice Date
2/19/2003
 
Notice Type
Modification
 
Contracting Office
Department of Energy, Duke Cogema Stone & Webster (DOE Contractor), Duke Cogema, 128 S. Tryon St. Suite FC12, Charlotte, NC, 28202
 
ZIP Code
28202
 
Solicitation Number
0888-R-0126
 
Response Due
3/3/2003
 
Archive Date
3/18/2003
 
Point of Contact
Andy Grodzicki, Buyer, Phone 803-644-6796 ext 3007, Fax 803-644-6799,
 
E-Mail Address
ajgrodzicki@duke-energy.com
 
Description
This acquisition is for design, fabrication, cutting, polishing, inspection and delivery of polycarbonate glovebox window panels to be used for the glovebox confinement boundary window at the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). The windows will provide visual access and permit external illumination of glovebox interior spaces. The polycarbonate window panel manufacturer shall design, fabricate, cut, polish, inspect and deliver panels in accordance with the requirements delineated in this specification and comply with all applicable codes, standards and regulations. The polycarbonate window panel material shall meet the following requirements in accordance with Design Requirements Document DCS01-ZMJ-DS-SPE-M-19101. 1. All polycarbonate window panels shall be 10mm nominal and 9.5mm (3/8?) minimum thickness. Greater thickness may be used if specified on procurement design drawings or if required to meet structural integrity requirements per the Process Equipment Fabricators? design calculations. 2.The maximum allowable window size shall be 1000mm by 1500mm. 3.Polycarbonate window panels shall be made of LEXAN MR-10, as manufactured by General Electric Corporation, or approved equal. 4.Windows shall be water clear window quality in conformance with Type I of Appendix X1 of ASTM C1349 with a minimum light transmission of 78% for a minimum thickness of 9.5mm. Optical and physical material properties shall remain essentially unaffected at a radiation exposure of 1x105 Rad Vendors are requested to visit the DCS MOX website to download the required forms. Potential Suppliers will need to download and send to DCS the following forms: Proprietary Agreement, Appendix I and Appendix II. The DCS website is www.dcsmox.com.
 
Place of Performance
Address: Various Locations
 
Record
SN00261364-W 20030221/030219213306 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.