Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 09, 2003 FBO #0464
MODIFICATION

93 -- Keel Blocks (Docking)

Notice Date
3/7/2003
 
Notice Type
Modification
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Kings Bay Det, 930 USS Hundley, Bldg 2012 Naval Submarine Base, Kings Bay, GA, 31547
 
ZIP Code
31547
 
Solicitation Number
N68836-03-T-0111
 
Response Due
3/12/2003
 
Archive Date
3/27/2003
 
Point of Contact
Carolyn Wilson, Purchasing Agent, Phone (912) 673-2001 x9283, Fax (912) 673-3776,
 
E-Mail Address
carolyn_b_wilson@jax.fisc.navy.mil
 
Description
This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number N68836-03-T-0111 is issued as a request for quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through the latest edition of the Federal Acquisition Circular. This solicitation is issued as 100% Set-A-Side for Small Business, NAICS Code 327331. Trident Refit Facility, Naval Submarine Base, Kings Bay, Ga. 31547 requires: 8-each Keel Blocks, Type A; and 8-each Keel Blocks, Type B; Specifications as follows: Blocks, Docking TYPE A and TYPE B (NOTE: the following specifications apply to both type A and B WITH THE EXCEPTION OF THREE ITEMS AS FOLLOWS: Pipe sleeve and thru-bolt (as indicated by drawing). Fill all bolt holes with silicone. Include material for a 3/4" chamfer on the corners of the blocks. these three items pertain to Type A block only)- concrete construction shall conform to the requirements of ACI 301 and ACI 318. Concrete shall be air-entrained having a minimum ultimate compressive strength of 3,000 PSI at 28 days. Cement shall conform to ASTM C150, Type II or Type III. If Type III is used, Tri-Calcium Aluminate shall be 8% or less of the mixture and compressive strength at 7 days must exceed 3,000 PSI. Aggregate shall conform to ASTM C33, with 1-1/2 inch maximum size. Reinforcing steel shall conform to A615-Grade 60. Calcium Chloride shall not be used. Compressive strength tests shall be performed for one set of three specimens for each 100 CY or fraction thereof placed in any one day. All sampling and testing shall be performed by an independent testing laboratory approved by the Contracting Officer. All timber shall be red or white oak, select car stock, in accordance with the 1978 edition of The National Hardwood Lumber Association "Rules for the measurement and inspection of hardwood and cypress lumber." All timber shall have the ends sealed with a coal-tar derivative. All timber/timber and timber/concrete interfaces shall be coated with a coal-tar or similar mastic. The mastic shall serve as a preservative and a parting agent for future timber replacement. Pipe sleeve and thru-bolt (as indicated by drawing). Pipe shall conform to ASTM A53 and shall be hot-dipped galvanized, any available type and grade, 1"NPS Schedule 40. Thru bolts: (or studs) and nuts and washers shall conform to ASTM A307 grade A and shall be hot-dipped galvanized in accordance with ASTM A153 class C. Tolerance: variation from parallel of top and bottom surface shall not exceed +/- 1/8 inch from vertical dimension of block. Fill all boltholes with silicone. Construction: the recommended construction technique is to use a steel form with tolerance dimension from top to bottom surfaces. Place timber, bolts, rebar, and lifting sleeves in the form, then place concrete. Include material for a ?" chamfer on the corners of the blocks. Blocks shall be made in accordance with drawing. (Drawings available from the Contracting Officer listed in this notice). The following provisions apply: 52.212-1 Instructions to Offerors-Commercial Items; 52.212-3 Offeror Representations and Certifications-Commercial Items; 52.212-4 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items and citing: 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.232-33; 52.219-1 Small Business Program Representations; 52.219-6 Notice of Total Small Business Set-Aside; 252.204-7004 Central Contractor Registration; 252.212-7001 Contract Terms and Conditions Required to Implement Statutes Applicable to Defense Acquisition of Commercial Items, and citing 252.225-7000; Offers are due by close of business on 28 Feb 2003 and may be faxed to 912/673-2191 or 912/673-2007; mailed to the Contracting Officer at the address provided in this notice, or emailed to the Contracting Officer at the address provided in this notice;
 
Place of Performance
Address: Trident Refit Facility, Receiving Officer, Code 5321, Bldg 4027, Naval Submarine Base, Kings Bay Ga
Zip Code: 31547
 
Record
SN00274105-W 20030309/030307213759 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.