SOLICITATION NOTICE
40 -- Single pair and five pair cables
- Notice Date
- 4/29/2003
- Notice Type
- Solicitation Notice
- Contracting Office
- Department of the Air Force, Air Combat Command, 55 CONS, 101 Washington Sq Bldg 40, Offutt AFB, NE, 68113-2107
- ZIP Code
- 68113-2107
- Solicitation Number
- F25600-03-T-0054
- Archive Date
- 5/28/2003
- Point of Contact
- Theresa Davis, Contract Administrator, Phone 402-294-2628, Fax 402-294-7280, - Patrick Foster, Contracting Officer, Phone (402)294-3546, Fax (402)232-6571,
- E-Mail Address
-
theresa.davis@offutt.af.mil, patrick.foster@offutt.af.mil
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is F25600-03-T-0054 and is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2001-13. This acquisition is 100% set aside for small business concerns. The NAICS Code for this acquisition is 541519 with a size standard of 21 million. The government intends to issue a firm fixed price purchase order for the following products. Item 01 ? 100 ea red single pair 1000? spools of shielded PVC 22 gauge cables; Item 02 ? 20 ea black single pair 1000? spools of shielded PVC 22 gauge cables; ITEM CHARECTERISTICS FOR SINGLE PAIR CABLE This specification details requirement for a double shielded twisted pair cable with a drain wire and a PVC exterior jacket of specified color. The cable will be constructed with the following characteristics: The inner conductor shall consist of two insulated 22AWG stranded tinned soft annealed copper wire. The twisted pair shielding shall consist of an inner aluminum polyester shield with a braided tinned copper outer shield. The twisted pair shield cable shall have an outer PVC jacket with color determined by part number. Individual Requirements: Conductor - 22 AWG stranded tinned, soft annealed copper wire. Strands will consist of 7 - 30 AWG wires. Pair color - Black paired with white. Pair Construction - Twist two (2) individual insulated conductors into one (1) pair having two twists per inch. The insulation shall be made of low-density polyethylene, with a nominal wall thickness of 0.015. Pair Drain Wire - a 22 AWG stranded tinned copper drain wire will be located between the foil shield and braid. The drain wire will electrically contact the foil shield throughout the running length. Pair Shield - The twisted pair shielded shall consist of an aluminum or double sided metalized Mylar shielding tape spirally wrapped over the twisted pair conductors. The spiral wrap shielding shall have a lay equal to the pairs. The 22 AWG drain wire make electrical contact over not less than 85% of its length. An outer shield consisting of a woven tinned copper shield shall provide not less than 80% coverage. The outer shield shall have an equivalent AWG of not less than 17 gauges. The braid angle shall be nominally 45 degree relative to the twisted pair wire lay. The braid shield shall electrically contact the foil shield throughout the running length. Jacket - Over the twisted, double shielded cable, apply a specific color pigmented 80 degrees C polyvinylchloride (PVC) compound jacket with .025 minimum average wall thicknesses. The cable overall diameter will be no more than .22 inches. Dielectric Strength - The dielectrically strength of the insulation between conductor shall be greater than 150 VDC. UL style 2464 shall be used for the outer jacket. Capacitance - The capacitance between conductors shall be 25 +5 pf/ft; the capacitance between either conductor or a pair to its associated shield shall be 42 +5 pf/ft. Impedance - The cable will have a nominal impedance of 58 +5 ohms. Cable Length - Unless otherwise specified in the purchase order, all cable shall be delivered in 1000-foot continuous (no break) length. Mark actual length of wire reeled for each spool. Quality Assurance Provision: The manufacturer assumes responsibility to ensure the cable furnished under this specification is of good workmanship and in accordance with the manufacturer's normal quality assurance practice. Packaging: Preparation for delivery - All cable should be adequately protected according to normal practices in order to prevent contamination, loss, or damage in transit. Shipping containers for spools shall be marked with the customer?s address, which will be identified on the award. Item 03 ? 10 ea red five pair 1000? spools of PVC 22 gauge cable; Item 04 ? 10 ea black five pair 1000? spools of PVC 22 gauge cable; ITEM CHARECTERISTICS FOR FIVE PAIR CABLE This specification details requirement for a double shielded twisted one pair cable with a drain wire and a PVC exterior jacket of specified color. The cable will be constructed with the following characteristics: The inner conductor shall consist of two insulated 22AWG stranded tinned soft annealed copper wire. The twisted pair shielding shall consist of an inner aluminum polyester shield with a braided tinned copper outer shield. The twisted pair shield cable shall have an outer PVC jacket with color determined by part number. Individual Requirements: Conductor - 22 AWG stranded tinned, soft annealed copper wire. Strands will consist of 7 - 30 AWG wires. Pair color - Black paired with white. Pair Construction - Twist two (2) individual insulated conductors into one (1) pair having two twists per inch. The insulation shall be made of low-density polyethylene, with a nominal wall thickness of 0.015. Pair Drain Wire - a 22 AWG stranded tinned copper drain wire will be located between the foil shield and braid. The drain wire will electrically contact the foil shield throughout the running length. Pair Shield - The twisted pair shielded shall consist of an aluminum or double-sided metalized Mylar shielding tape spirally wrapped over the twisted pair conductors. The spiral wrap shielding shall have a lay equal to the pairs. The 22 AWG drain wire make electrical contact over not less than 85% of its length. An outer shield consisting of a woven tinned copper shield shall provide not less than 80% coverage. The outer shield shall have an equivalent AWG of not less than 17 gauges. The braid angle shall be nominally 45 degree relative to the twisted pair wire lay. The braid shield shall electrically contact the foil shield throughout the running length. Jacket - Over the twisted, double shielded cable, apply a specific color pigmented 80 degrees C polyvinylchloride (PVC) compound jacket with .025 minimum average wall thicknesses. The cable overall diameter will be no more than .22 inches. Dielectric Strength - The dielectrically strength of the insulation between conductor shall be greater than 150 VDC. UL style 2464 shall be used for the outer jacket. Capacitance - The capacitance between conductors shall be 25 +5 pf/ft; the capacitance between either conductor or a pair to its associated shield shall be 42 +5 pf/ft. Impedance - The cable will have a nominal impedance of 58 +5 ohms. Cable Length - Unless otherwise specified in the purchase order, all cable shall be delivered in 1000-foot continuous (no break) length. Mark actual length of wire reeled for each spool. Quality Assurance Provision: The manufacturer assumes responsibility to ensure the cable furnished under this specification is of good workmanship and in accordance with the manufacturer's normal quality assurance practice. Packaging: Preparation for delivery - All cable should be adequately protected according to normal practices in order to prevent contamination, loss, or damage in transit. Shipping containers for spools shall be marked with the customer?s address, which will be identified on the award. Item 05 ? All necessary parts required to install 100 subscribers off of the red switch ( a digital Private Branch Exchange (PBX)). Item 05a--20 ea DB37 Backshell straight Kern Engineering P/N SDM-37 Shielded/RFI Item 05b--150 ea DB25 Backshell Right Angle Kern Engineering P/N CTO1643 Shielded/RFI Item 05c--150 ea DB25 Backshell straight, Kern Engineering P/N SDM-25 Shielded/RFI Item 05d--50 ea DB9 Backshell straight Kern Engineering P/N SDM-9 Shielded/RFI Item 05e--20 ea DB37 Socket Newark P/N 44F8719 Item 5f--20 ea DB37 Plug Newardk P/N 44F8714 Item 5g--300 ea DB25 Plug Newark P/N 44F8713 Item 5h--300 ea DB25 Socket Newark P/N 44F8718 Item 5i--50 ea DB9 Plug Newark P/N 44F8711 Item 5j--50 ea DB9 Socket Newark P/N 44F8716 Item 5k--10 pkg Crimp pin, male Newark P/N 44F8721 Item 5l--10 pkg Crimp pin, female Newark P/N 44F8722 Item 5m--30 ea Spring, Iris DB25 BS Rangle, Kern Engineering P/N 11900-15/12. Item 5n--30 ea Spring, Iris DB25 BS straight, Item 5o--5 ea copper foil Newark P/N CST-15 Item 5p--300 ea Stewart Socket 6 pin orange Kennington Electronics P/N SS620606FF-P1-3-4 Item 5q--300 ea Stewart Plug 6 Pin Orange Kennington Electronics P/N SS310606-3 Item 5r--100 ea Recetacle Cover DB25(1 hole ) RED Computer Connections P/N 4X4 cover plate Item 5s--100 ea Recetacle Cover DB25(2 hole) RED Computer Connections P/N 4X4 cover plate Item 5t--100 ea Receptacle Cover DB25(3 hole) RED Computer Connections P/N 4X4 cover plate Item 5u--100 ea Receptacle Cover Stewart (1 hole) Computer Connections P/N use 2X4 single Gang Item 5v--100 ea Receptacle Cover Stewart (2 hole) Computer Connections P/N use 2X4 single Gang Item 5w--100 ea Receptacle Cover Stewart (3 hole) Computer Connections P/N use 2X4 single Gang Item 5x--100 ea Cinch Backshell IEC P/N DB15HSD Item 5y--20 ea Insertion/Extraction Tool Newark P/N 44F8729 Item 5z--100 ea Condulet (Drop Box 4X4) Consolidated Electric P/N 2FS2M(FD22) Item 5aa--5 ea Nylon Screws GSA Advantage online P/N FMS634N 5ab--10 ea RED Tape Grainger P/N 2A229 Item 5ac--100 ea Cover/Gasket for Condulet Consolidated Electric P/N S1002G Item 5ad--50 ea Heat Shrink (1/8 in) Computer Connections P/N 38-10-018 Item 5ae--50 ea Heat Shrink (3/4 in) Computer Connections P/N 38-10-034 Item 5af--50 ea Heat Shrink (3/8 in) Computer Connections P/N 38-10-039 Item 5ag--50 ea Heat Shrink (1/2 in) Computer Connections P/N 38-10-040 Item 5ah--50 ea Heat Shrink (1 in) Computer Connections P/N 38-10-041 Item 5ai--150 ea QTI Fuses Newark P/N 50F3414 Item 5aj--1000 ea Tie Straps (5 1/2 in) Computer Connections P/N 30-06-100 Item 5ak--1000 ea Tie Straps (7 1/2 in) Computer Connections P/N 30-06-100 Item 5al--1000 ea Tie Straps (14 12/ in) Computer Connections P/N 30-06-100 Item 5am--1000 ea Tie Straps (4 in) Computer Connections P/N 30-06-100 Item 5an--4 ea Tie Straps (velcro) 15 ft roll Computer Connections P/N 30-06-20 Blue Item 5ao--4 ea Tie Straps (velcro) 15 ft roll Computer Connections P/N 30-06-21 Black Item 5ap--4 ea Tie Straps (velcro) 15 ft roll Computer Connections P/N 30-06-23 Red Item 5aq--4 ea Tie Straps (velcro) 15 ft roll Computer Connections P/N 30-06-24 Green Item 5ar--150 ea Screw lock kits, female Newark P/N 90F5299 Item 5as--300 ea Screw lock kits, male Newark P/N 44F8770 Item 5at--1 ea Jack Screws Male to Female Newark P/N 89F2591 Connecting male/Female DB25 External Ringer Pieces Separate Item 5au--10 ea Connector, ring Newark P/N CRS-DY-1804 Item 5av--10 ea Receiver X10 P/N PF284 Item 5aw--30 ea Ringer, Chims X10 P/N SC546 Installation will be accomplished by the government. Prefer quotes have delivery terms of FOB Destination to Offutt AFB, NE. Delivery Schedule is as follows: Four possible deliveries, to be arranged by Mr. Moo Stranhoener during the contract performance period; 1) Initial partial delivery of 50 spools, single red pair to third floor of bldg 500. 2) Partial delivery of spools to be determined, single red pair to third floor of bldg 500. 3) Partial delivery of spools to be determined, single red, single black, five pair red, and five pair black to L102 of bldg 501. 4) Final delivery of any remaining cables to Bldg D, room to be determined. The following provisions and clauses apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial; FAR 52.212-2, Evaluation- Commercial Items, (a. Price and delivery, in order of importance); (Offerors must include a complete copy of 52.212-3, Offeror Representation and Certifications -- Commercial Items with offer which can be found at http://farsite.hill.af.mil/vffara.htm); FAR 52.212-4, Contract Terms and Conditions Required to Implement Status of Executive Orders -- Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders -- Commercial Items (paragraphs (b)(11),(b)(12), (b)(13), (b)(14) (b)(15) (b)(15) (b)(18) (b)(24) are checked for the purpose of this clause). Please reference solicitation # F25600-03-T-0054 on all correspondence. No numbered notes are applicable to this acquisition. All quotes are due no later than 13 May 03 at 4:00 p.m. (cst) to 55 CONS/LGCB. Quotations may be submitted via e-mail to theresa.davis@offutt.af.mil , faxed to 402-294-7280, or mailed to the attention of SSgt Theresa Davis at 55 CONS/LGCB, 101 Washington Sq. Bldg 40, Offutt AFB, NE 68113. Contact SSgt Theresa Davis at (402) 294-2628 with any questions. NOTE: CONTRACTORS MUST BE CCR REGISTERED PRIOR TO RESPONSE DUE DATE OF 13 MAY 03. TO REGISTER, GO TO THE WEB SITE: http://www.ccr.dlsc.dla.mil.
- Place of Performance
- Address: Offutt AFB, NE
- Zip Code: 68113
- Country: USA
- Zip Code: 68113
- Record
- SN00314208-W 20030501/030429213426 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |