Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 04, 2003 FBO #0521
SOLICITATION NOTICE

J -- Operation and Maintenance of Base Telecommunications System at Moody AFB GA

Notice Date
5/2/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, 38 EIG/PK, 4064 Hilltop Road, Tinker AFB, OK, 73145-2713
 
ZIP Code
73145-2713
 
Solicitation Number
F34608-03-R-0003
 
Archive Date
12/18/2003
 
Point of Contact
Kaye Roa, Contract Specialist, Phone (405)734-9708, Fax (405) 734-9220, - Kelvin Carrington, Contracting Officer, Phone (405) 734-9776, Fax (405) 734-9220,
 
E-Mail Address
Kaye.roa@tinker.af.mil, kelvin.carrington@tinker.af.mil
 
Description
The 38th Engineering Installation Group/PKL, Contracting Division, has a requirement for non-personal services for operations, maintenance (O&M) and recurring support services of the Base Telecommunications System (BTS) for Moody AFB GA. The proposed contract is for a base period and four option periods totaling approximately 60 months and is a total 100% Small Business set-aside under NAICS 811212. The services would include providing all personnel, equipment, parts, material, tools, operation and maintenance documentation and any other items and services necessary to perform operations and maintenance of the Base Telecommunications System (BTS), Moody AFB GA. Perform operations and maintenance on switching systems, transmission equipment, ancillary equipment, auxiliary equipment, customer premise equipment, and the inside and outside cable plant. Moody AFB utilizes a MSL-100 SUPERNODE Switching System with MSL-15 Software. The switching system is comprised of a host switch and two remotes switch terminal (RST00 and RST01) and located in Building 5118, Building 3404 and Building 9569, respectively. The switching system is assigned approximately 4,805 lines, equipped with 4,991 lines, and wired for 7,168 lines. Wired for approximately 190 trunks. The Host uses PRI T1 trunking for DSN, Commercial and Long distance circuits. Remote Switching Terminal (RST 00). The RST00 is assigned approximately 977 lines, equipped with 1,085 lines and wired for 3075 lines, and is located in Moody AFB GA, building 3404. The Switch is configured with the following cabinets and shelves:Remote Switching Terminal (RST 01). The RST01 is assigned approximately 393 lines and wired for 1024 lines and is located in Moody AFB GA building 71 ACS Compound. The Switch is configured with the following cabinets and shelves: Billeting switch, Mitel SX2000 assigned 96 lines and 18 trunks. All responsible domestic offierors may submit proposals. CBD Note 1 applies. For this acquisition, a concern will be considered small under NAICS code 811212 with size standard of $21,000,000.00. Based upon market research, the Government will not be using the policies contained in Part 12, Acquisition of Commercial Items, in this solicitation for the described supplies and services. The RFP will be paperless and will be released using the Electronic Posting System (EPS) via the www (www.eps.gov). The RFP will contain files in MS Word 2000 Version 9.0 and MS Excel 2000. DO NOT request any documents in writing. A registration page for the solicitation will be available at the solicitation web page.
 
Place of Performance
Address: Moody AFB, GA
 
Record
SN00316900-W 20030504/030502213427 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.