Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 17, 2003 FBO #0595
SPECIAL NOTICE

16 -- Request for Industry comments on Draft Statement of Objectives for repair of the Coast Guard''s HU25 Nose Cowlings. POC Mr. J. J. Tirak, 252-335-6877.

Notice Date
7/15/2003
 
Notice Type
Special Notice
 
Contracting Office
DHS - Direct Reports, United States Coast Guard (USCG), Commanding Officer, USCG Aircraft Repair & Supply Center, HU25, HH65, H60J, C130 or Support Procurement Building 79, 75, 79, 78, or 63, Elizabeth City, NC, 27909-5001
 
ZIP Code
27909-5001
 
Solicitation Number
PN-553-0170
 
Response Due
7/31/2003
 
Archive Date
8/15/2003
 
Point of Contact
Linda Clark, HU25 Contract Specialist, Phone 252-334-5212, Fax 252-334-5427, - Joyce Hudson, HU25 Contracting Officer, Phone 252-335-6142, Fax 252-334-5427,
 
E-Mail Address
LDClark@arsc.uscg.mil, LHudson@arsc.uscg.mil
 
Description
U.S. COAST GUARD HU25 ATF3-6 ENGINE NOSE COWLING (PN 553-0170 SERIES) REPAIR STATEMENT OF OBJECTIVES 1.0 BACKGROUND The U.S. Coast Guard currently operates twenty (20) HU-25 aircraft manufactured between 1982 and 1984 by Dassault-Breguet Aviation SA-Avions Marcel (Falcon Jet Corporation). Each aircraft is equipped with two Honeywell ATF3-6 fan jet engines. Typical failure modes of ATF3-6 engine nose cowlings are material cracks that propagate as a result of various environmental factors. Some of these include: vibration, corrosion, thermal fatigue and erosion. These failures occur primarily at the nose cowling nose lip rivet lines. Past history shows that a complete or partial disassembly of the nose cowling is necessary for thorough inspection and repair or replacement of damaged components. 2.0 OBJECTIVE A. The Coast Guard?s objective is to obtain services of a Federal Aviation Administration (FAA) authorized repair center to effectively repair and provide complete, ready-to-install HU-25 ATF3-6 nose cowling assemblies. Repaired nose cowlings must meet the Original equipment Manufacturer?s (OEM?s) form, fit and function specifications to ensure installation and operational characteristics are met. The contractor shall replace the original aluminum nose lip PN 553-0169-1 with a nose lip manufactured from 321 stainless steel. The stainless nose lip must meet all thermal properties as the aluminum nose lip. In addition, corrosion preventative measures shall be incorporated during repair. The offeror is responsible for all necessary functions to perform services requested. This includes, but is not limited, required tooling, test equipment, parts, material, engineering services, management, maintenance, preservation, shipping, etc., to repair nose cowlings. The offeror?s responsibilities to Coast Guard consist of preparing and submitting a detailed work specification and cost breakdown structure for repair and ensure that all Coast Guard Time Compliance Technical Orders (TCTOs) remain incorporated upon completion of work. Under a performance-based contract structure, performance metrics and service level agreements will be used to monitor the performance of this contract. The Coast Guard Aircraft Repair and Supply Center?s (ARSC) HU-25 Product Line and the winning offeror will baseline and monitor progress using agreed-to performance metrics and service level agreements. B. To meet the Coast Guard?s objectives the offeror will be required to meet the following criteria: 1. Technical a. Provide detailed work specifications for nose cowling repair. b. Provide a written Performance Metrics plan. c. Provide evidence of and ability to maintain a Quality System acceptable to the Coast Guard. d. Either possess or show ability to obtain adequate technical data, tooling and fixtures to meet the OEM?s form, fit and function characteristics. e. Provide separate cost breakdowns for nose cowling repair (labor and parts). Replacement nose lip shall be priced separately. Note 1: Exterior paint scheme for the engine nose cowling consists of AKZO Primer P/N 10P20-13and US Paint topcoat K8080. Note 2: Stop drilling of cracks or use of flush patches are considered temporary repairs and are not permissible repairs for the purpose of this contract. Note 3: Note: Modifications or acceptable alternatives must be approved by the U.S. Coast Guard?s HU-25 Engineering Cell at ARSC. 2. Past Performance a. Provide documentation for having performed repair of similar or like items. b. Provide Points of Contact for past performance documentation for the past two years. Include references? name, company, phone number, and e-mail address. 3.0 APPLICABLE DOCUMENTS The following Technical Specifications are applicable: a. CG Technical Orders: 1. 1U-25A-2, HU25 Maintenance Manual (Chapters 54-00-02, 54-00-3, 54-00-04 and 71-00-03) 2. 1U-25A-3, HU25 Structural Repair Manual (Chapters 51, and 54-10-20) 3. 1U-25A-4, HU-25 Illustrated Parts Catalog (Chapter 54-20-25, pages 10-0, 10-1, 21-0, 21-1, and 21-2 b. CG Time Compliance Technical Orders (TCTO) 1. 1U-25A-522, Nacelle Anti-Ice Exhaust Improved Sealing, ACMS Code 995220, dated 14 July 83 2. 1U-25A-533, Engine Nacelle Improved Support for PT2 Duct Water Trap, ACMS Code 995330, dated 28 Nov 83 3. 1U-25A-536, Check and Rework Ice Detector Bracket, ACMS Code 995360, dated 01 March 86 4. 1U-25A-568, Air-Intake reinforced pressure Switch Supports, ACMS Code 995680, dated 4 Feb 85 5. H25-T54110, LH & RH Inlet Anti-Icing Ducting, ACMS code T54110, dated 7 May 02 b. Data Availability: 1. OEM drawings and specifications are proprietary and cannot be provided by the Coast Guard. 2. Coast Guard specific CGTOs, and TCTOs can be acquired through the Freedom of Information Act (FOIA). Submit a written request to: Commanding Officer Attn: ARSC FOIA Officer United States Coast Guard Aircraft Repair & Supply Center Elizabeth City, NC 27909
 
Record
SN00371281-W 20030717/030715213101 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.