SOLICITATION NOTICE
66 -- Small Environmental Chamber
- Notice Date
- 7/18/2003
- Notice Type
- Solicitation Notice
- Contracting Office
- US Army Communications-Electronics Command, CECOM Acquisition Center Washington, ATTN: AMSEL-AC-W, 2461 Eisenhower Avenue, Alexandria, VA 22331-0700
- ZIP Code
- 22331-0700
- Solicitation Number
- DAAB1503Q0005
- Response Due
- 8/1/2003
- Archive Date
- 9/30/2003
- Point of Contact
- Susie Shupe, 703-325-2856
- E-Mail Address
-
US Army Communications-Electronics Command, CECOM Acquisition Center Washington
(susie.shupe@cacw.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- NA This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are b eing requested and a written solicitation will not be issued. The US Army CECOM RDE Center, Army Power Division, Ft. Belvoir, VA, intends to purchase a small environmental chamber for the purpose of testing small fuel cells. Candidates responding to this request for quote shall be non-developmental (in production), and shall be ready for delivery in 6 weeks or less from the receipt of contract. Unit shall be delivered ready for operation; if technical support is required during installation that cost shall be included in the quotation. The following technical perf ormance features are required: 1. Interior Size: Min. 27 cu. Ft; 32 cu. Ft. desired 2. Exterior Size: Maximum 70â wide x 70â deep x 83â high [Note: A chamber that can be partially disassembled or assembled on site to meet the 83â door clearance height requirement is acceptable.] 3. Temperature Range: Min. -35C to 177C (-31F to 350F) 4. Temperature Stability/Control Accuracy: 1 degree C at steady state after stabilization 5. Temperature Pulldown: From +24C to -18C in 20 minutes; -35C in 30 minutes. 6. Live Load Capacity: 1000 watts at â30C. Note: 2-5 scfm make up air will be used; to be provided by government. 7. Humidity range: 10% RH to 98% RH; bounded by maximum dry bulb temperature of 85C and minimum 4C dew point. 8. Humidity control: +/- 5% RH as measured at the control sensor. 9. Input Power: 230V single phase or 208V three-phase; 60 amp circuit or less. 10. Air-cooled refrigeration system. 11. Fog-free viewing window in door. 12. 3-4 access ports with plugs for wiring, tubing, etc; at least two of these 2.875â minimum diameter. 13. Programmable controller with IEEE-488 or RS-232 computer interface. 14. Heavy-duty casters. Responses should be no longer than ten (10) pages. The resultant contract will be firm fixed price. Responses are to be received via email NLT 1 August 2003. All requests for further information must be in writing or via email, telephone requests for ad ditional information will not be honored. Technical questions are to be directed to Christopher.Bolton@armypower.army.mil. You may forward responses to the following e-mail address: Susie Shupe, Procurement Assistant, e-mail: Susie.shupe@CACW.army.mil o r Wanda G. Fair, Contracting Officer, e-mail: Wanda.Fair@cacw.army.mil.
- Web Link
-
Link to FedBizOpps document.
(http://www.eps.gov/spg/USA/USAMC/DAAB15/DAAB1503Q0005/listing.html)
- Place of Performance
- Address: US Army Communications-Electronics Command, CECOM Acquisition Center Washington ATTN: AMSEL-AC-W, 2461 Eisenhower Avenue Alexandria VA
- Zip Code: 22331-0700
- Country: US
- Zip Code: 22331-0700
- Record
- SN00375748-F 20030720/030718222121 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |