SOURCES SOUGHT

J -- HVAC Mechanical Maintenance

Notice Date
7/28/2003
 
Notice Type
Sources Sought
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, Engineering Field Division, South, ROICC Charleston, 2120 Quality Circle, Goose Creek, SC, 29445
 
ZIP Code
29445
 
Solicitation Number
N62467-03-R-8301
 
Response Due
7/14/2003
 
Archive Date
7/29/2003
 
Point of Contact
Mae Bartley, Contract Specialist, Phone 843-764-4112 x-3007, Fax 843-764-4157, - Mae Bartley, Contract Specialist, Phone 843-764-4112 x-3007, Fax 843-764-4157,
 
E-Mail Address
bartleymk@efdsouth.navfac.navy.mil, bartleymk@efdsouth.navfac.navy.mil
 
Description
THIS IS A MARKET SURVEY. Naval Facilities Engineering Command, ROICC Charleston is seeking interested sources for maintenance and repair services for HVAC and chilled water equipment/systems for five buildings at the Space and Naval Warfare Systems Command, Naval Weapons Station, Charleston. The work includes providing all labor, transportation, equipment, materials, tools, supplies, and supervision required to perform the inspections, testing, maintenance, repair, and component replacement as required to maintain the following, but not limited to, type equipment and peripheral systems: Water chillers/air conditioning units including large (300 ton) reciprocating and high pressure rotary screw compressor equipped chillers; Air Handling Systems; Variable Air Volume Terminals; Pumps; Electric Motors and Controllers; Chilled Water Piping Systems; Chilled water system chemical treatment, including chemicals; Adjustable frequency drives; Computer room air conditioning units; Mechanical thermal insulation; HVAC control systems to include microprocessor-based Direct Digital Controls (includes Metasys and Automated Logic Direct Digital Controls); Steam/Hot water boilers; Dehumidifiers; Steam Humidifier sand Exhaust fans. This effort requires the offeror to have required knowledge, understanding and experience with the above-mentioned equipment and peripheral systems. This procurement may result in the award combination firm fixed price/indefinite quantity type contract. The performance period for this potential contract is 5 years. Firms having the required specialized experience with the above systems are invited to submit appropriate documentation, literature, brochures, and references. Responses shall be limited to 8 pages and should be submitted to Naval Facilities Command, ROICC Charleston, Attn: M. Bartley, 2120 Quality Circle, Goose Greek, SC 29445 or by electronic mail to bartleym@efdsouth.navfac.navy.mil. Responses must include the following: (1) name and address of firm, (2) size of business: average annual revenue for past 3 years and number of employees, (3) ownership, i.e., : Large, Small, Small Disadvantaged, 8(a), and/or Woman-Owned; Hubzone, etc. (4) number of years in business; (5) two points of contact: name, title, phone, fax and e-mail; (f) DUNS Number and CAGE Code (if available) and applicable NAICS Code; (g) affiliate information: parent corporation, joint venture partners, potential teaming partners, prime contractor (if potential sub) or subcontractors (if potential prime), (h) describe experiences, as either a contractor or subcontractor (identify which), with maintenance and repair HVAC and chilled water equipment identifying the types of systems maintained; describe experiences in preventive maintenance inspection and services (PMIS); routine/periodic inspection test; service call, water treatment and minor work, In addition, firms are requested to submit information on the following: a) Response time - Do to the critical nature of SPAWAR operations all bidders must ensure that a real person (not recording or pager) must be available for emergency calls 24 hours a day, 7 days a week. Response to an emergency call cannot exceed four (4) hours;. b) Safety Information -All bidders must provide documentation of an OSHA approved safety training program with their bid. c) Manpower/Technician Qualifications - A prospective bidder?s workforce should consist of no fewer than six (6) technicians qualified to troubleshoot, diagnose, and repair reciprocating and high-pressure rotary screw compressor equipped chillers, as well as variable frequency drives, and microprocessor-based Direct Digital Controls. The bidders workforce should also be qualified to maintain and repair steam and hot water boilers. To properly maintain the controls system, bidders should have documentation of sufficient training of personnel in Metasys and Automated Logic Direct Digital Controls. d) Refrigerant Certification - Bidders must provide documentation of EPA refrigerant certification. Bidders must have at least three (3) technicians with universal certification and at least three (3) technicians with standard EPA refrigerant certification. e) Parts Procurement -In order to ensure expeditious parts procurement, bidders must include a summary list of parts suppliers with whom they have an open line of credit in good standing. f) Liability Insurance - Bidders must include proof of general liability insurance with a minimum coverage of three (3) million dollars. f) Past Experience - Bidders must include a list of references and contacts of past experience with large, (up to 300 ton) reciprocating and high-pressure rotary screw compressor equipped chillers, variable frequency drives, microprocessor-based Direct Digital Controls, steam and hot water boilers. Identify relevant work including a summary of work performed, contract number, contract type, dollar value for each customer reference, and customer point of contact with phone number. THIS SYNOPSIS IS FOR INFORMATION AND PLANNING PURPOSES AND IS NOT TO BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. THIS IS NOT A SOLICITATION ANNOUNCEMENT FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUNCEMENT. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS ANNOUNCEMENT AND ANY FOLLOW-UP INFORMATION REQUESTS. RESPONDENTS WILL NOT BE NOTIFIED OF THE RESULTS OF THE EVALUATION. RESPONDENTS DEEMED FULLY QUALIFIED WILL BE CONSIDERED IN ANY RESULTING SOLICITATION FOR THE REQUIREMENT. THE GOVERNMENT RESERVES THE RIGHT TO CONSIDER A SMALL BUSINESS SET-ASIDE OR 8(A) SET-ASIDE BASED ON RESPONSES HERETO. THE APPLICABLE NAICS CODE IS 238220 WITH A SIZE STANDARD OF $12 MILLION IN ANNUAL RECEIPTS. CLOSING DATE FOR RESPONSES IS 14 JULY 2003.
 
Place of Performance
Address: Hanahan, South Carolina
Zip Code: 29419
Country: US
 
Record
SN00384833-W 20030730/030728213800 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.