Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 22, 2003 FBO #0631
SOLICITATION NOTICE

Q -- LABORATORY REAGENTS AND ANALYZER

Notice Date
8/20/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC PUGET SOUND, 467 W STREET, BREMERTON, WA, 98314-5000
 
ZIP Code
98314-5000
 
Solicitation Number
N00406-03-T-2514
 
Response Due
9/16/2003
 
Archive Date
10/1/2003
 
Point of Contact
Andrew Ross, Contract Specialist, Phone 360-476-2804, Fax 360-476-5652,
 
E-Mail Address
andrew_d_ross@puget.fisc.navy.mil
 
Description
This is annual requirement for numerous laboratory reagents including the analyzer in support of Naval Hospital Oak Harbor, Oak Harbor, WA. Must be a single analyzer that does the following (no multiple units may be considered, we do not have the staffing to support multiple platforms): a. Cardiac testing: CK, MMB, MYO, cTNI, and high sensitivity (hs)CRP b. General Chemistry testing: CL, CO2 (enzymatic only), K, NA, ALB, BUN, CA, CHOL, CREA, GLU, PHOS, TBIL, TP, URCA, ALKP, DBIL, GGT, GOT(AST), GPT(ALT), LDH, TRIG, AMY, ALC, CRP, AHDL (no pretreatment), IRN, MG, IBCT (no pretreatment), CFP, c. Immunochemistry testing: BHCG, TSH, and FreeT4 Must be no larger than 52 inches wide by 34 inches deep by 56 inches high to allow for placement in the chemistry section. There is a definite lack of space to allow anything larger. Must be able to draw all samples from a single patient tube (mo multiple tubes needed). No need to split samples. Must be able to run all necessary testing without sample pre-treatment (i.e HDL, Iron, and TIBC) Must run on 110-volt standard power lines. Independent and simultaneous immunoassay processing (can do both chemistry and Immunochemistry tests separately - while running them both at the same time ? you don?t have to wait for one to stop so the other can begin). Lab defined panic values. Auto rerun and auto dilution capabilities. Must be able to self contain its waste in a system that will allow disposal in a landfill (i.e. a self-producing and sealing cuvette system). Must be capable of handling various size bar code tubes and sample cups. No reagent preparation. Stores a minimum of 2 calibration curves for each analyte. Installation and removal of equipment. Training of government personnel for operation of equipment. Minimal user maintenance, less than 5 minutes daily and 10 minutes once a week.
 
Record
SN00407751-W 20030822/030820214145 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.