SOLICITATION NOTICE
12 -- 1000 Foam Trailer
- Notice Date
- 9/18/2003
- Notice Type
- Solicitation Notice
- Contracting Office
- 151 ARG/LGC, 765 North 2200 West, Salt Lake City, UT 84116-2999
- ZIP Code
- 84116-2999
- Solicitation Number
- DAHA4232470500
- Response Due
- 9/24/2003
- Archive Date
- 11/23/2003
- Point of Contact
- Chad Heard, (801) 245-2338
- E-Mail Address
-
Email your questions to 151 ARG/LGC
(chad.heard@utsalt.ang.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- NA This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are b eing requested and a written solicitation will not be issued. This is a combined synopsis and solicitation for the following commercial items, Item Description: CLIN 1: FT/LDH 1000 Foam Trailer. Description: The following specifications are for a mobi le foam re-supply trailer of 1000-gallon capacity with accessories for use as a firefighting unit. The foam re-supply trailer offered shall comply with all applicable Motor Carrier Safety Regulations, as it pertains to municipal emergency firefighting, co ncerning size, weight, brakes, lights, load rating and balance. GVWR ?????? Gross vehicle weight rating shall not exceed 12,680 pounds when fully loaded and equipped. Size ?????? Overall size of completed trailer (less packaging) not to exceed (approx.) 234inch long, 88inch wide, and 60inch high when measured from the ground surface. Axles- There shall be two axles, each with a rated capacity of 7,000 lbs. properly located under the trailer frame. Each wheel is to have individual functioning electric bra ke. Brakes shall have slack adjusters accessible from the backside of the backing plate. The bearings shall be sealed grease type. Hubs shall be cast type with pressed in wheel studs. The suspension shall meet or exceed the capacity of the axles and shall have slipper type springs. The main equalizer pivot point of the suspension shall have grease fittings. Tires and Wheels ?????? Tires to be minimum 9.50 x 16.5 tires. Wheels to be 9.75 x 6.75 rated for 3170 lbs. at 75 psi. And shall be matched to tires. Foam Tank - Size ?????? Capacity for 1,000 U.S. gallons. Low center of gravity type with adequate baffles. Construction - The foam tank shall be constructed from ????inch PT2E co-polymer sheet stock. The material shall be a non-corrosive stress relieved t hermo-plastic, black in color and UV stabilized for maximum protection. The tank shall be designed to be an independent component of the completed vehicle. All joints shall be welded using Nitrogen shielding gas and tested for maximum weld integrity. The t ransverse partitions are to be fabricated from 3/8 polypropylene and shall be natural in color and shall extend from within 4inch of the tank floor to the underside of the covers. The longitudinal partitions shall be fabricated from ????inch polypropylene (black in color) and extend from the floor thru the covers to allow for positive welding and maximum integrity. All partitions shall be equipped with vent and flow holes to permit proper flow of foam and air within the tank under all conditions. All partit ions interlock with each other and are fully welded to the sidewalls of the tank as well as to each other. The tank covers shall be of a flush design to eliminate trapping of water or foam on the top surface. Hose Compartments- There shall be two (2) cros s lay type hose beds approximately 12inchH x 10inch W across the front of the tank. Each compartment shall have a minimum capacity of 200 feet of 1.75inch double-jacketed fire hose. These hose beds shall hold the hose to be used for foam concentrate transf er operations. Each cross lay shall be labeled CROSS LAY ?????? CONCENTRATE #1, AND CROSSLAY CONCENTRATE #2 respectively. Pump - There shall be a 100 GPM self??????priming gasoline driven pump for on loading and off loading the foam concentrate. Pump to b e cast iron with foam resistant internal components. Pump is to have an electric start with recoil back up, fuel tank and battery. A battery box shall be fabricated from ????inch co-polymer polypropylene sheet stock to hose battery. This box shall have a r emovable cover and shall have 5inch x 5inch vented side panel. The pump shall be mounted at front on the A frame portion of the trailer frame. A plastic isolato r shall be installed under pump to eliminate contact of dissimilar metals. Provisions to manually fill the pump initially shall be provided. This shall be labeled fill to prime. A yellow warning label shall be placed near the pump start controls, which rea ds. Do not run engine with pump dry or pump seal will be damaged. Fill prime port prior to starting. CLIN 2: Lighting Package: 200-Watt Honda Generator and two 500-watt telescoping floodlights. This synopsis and solicitation is prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is issued as a request for quote (RFQ). Submit written offers (oral offers will not be accepted), on RFQ F13LVL20194130. All firms or individuals responding must be registered with the Central Contractor R egistration (CCR). This procurement is being issued as 100% SMALL BUSINESS SET-ASIDE. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-14 and Defense Acquisition Circular 91-13. North American Industrial Classification Standard 423110, Size Standard, 500 employees, applies to this procurement. FOB: Destination for delivery to Bldg 3971, LACKLAND AFB, TX 78236.The following provisions and clause apply to this acquisition: FAR 52.21 1-6 Brand Name or Equal. The provision at FAR 52.212-1, Instructions to Offerors--Commercial Items, applies to this solicitation. Quotes will be evaluated on price related factors only. The provision at FAR 52.212-3, Offeror Representations and Certificat ions -- Commercial Items, applies to this solicitation and the offeror must include a completed copy of this provision with their proposal. The clause at FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders--Commer cial Items, applies to this solicitation. Specifically, the following clauses cited are applicable to this solicitation: FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-3 6, Affirmative Action for Handicapped Workers; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-42, Statement of Equivalent Rates for Federal Hires 52.222-48. The clause at DFARS 252.212-7001, Contract Term s and Conditions Required to Implement Statues or Executive Orders applicable to Defense Acquisition of Commercial Items, applies to this solicitation. Specifically, the following clauses, cited are applicable to this solicitation: DFARS 252.225- 7001, Buy American Act and Balance of Payment Program. The clause at FAR 52.212-4, Contract Terms and Conditions-Commercial Items, applies to this solicitation. The clause at FAR 52.224-1, Privacy Act Notification and FAR 52.224-2, Privacy Act, applies to this soli citation. The Government reserves the right to award on a multiple award or an all or none basis. All quotes must be emailed to SSgt Chad Heard at chad.heard@utsalt.ang.af.mil. Quotes are required to be received no later than 12:00 PM MST, Tuesday, Septem ber 24, 2003.
- Place of Performance
- Address: 151 ARG/LGC 765 North 2200 West, Salt Lake City UT
- Zip Code: 84116-2999
- Country: US
- Zip Code: 84116-2999
- Record
- SN00437549-W 20030920/030918213251 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |