MODIFICATION
J -- Corrective and Preventive Maintenance Contract for Kodak Dry Viewer Laser Imagers and Components
- Notice Date
- 9/18/2003
- Notice Type
- Modification
- Contracting Office
- Department of the Navy, Bureau of Medicine and Surgery, NMC San Diego, Bldg 1 38400 Bob Wilson Drive, San Diego, CA, 92134-5000
- ZIP Code
- 92134-5000
- Solicitation Number
- N00259-03-T-0083
- Response Due
- 9/25/2003
- Archive Date
- 10/10/2003
- Point of Contact
- Kohala Hembre, Purchasing Agent GS-1105-07, Phone 619-532-9570, Fax 619-532-5596,
- E-Mail Address
-
KOHembre@nmcsd.med.navy.mil
- Description
- This is a combined synopsis/solicitation for commercial items or services, prepared in accordance with the format in FAR subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. The solicitation number, N00259-03-T-0083 is issued as a request for quotation (RFQ). This acquisition is unrestricted and order will be a firm fixed price order. NAICS: 811219, size: $6.0M. All responsible businesses may submit a quote that shall be considered. All inquiries and/or quotations should be directed to the purchasing agent, Kohala Hembre, Naval Medical Center San Diego, 34800 Bob Wilson Drive, San Diego, CA, 92134, or e-mail: kohembre@nmcsd.med.navy.mil, or fax 619-532-5596 no later than September 12, 2003, 2:30 p.m. PDT. No phone inquiries will be accepted. In accordance with FAR 52.212-2, Evaluation - Commercial Items (1999), award will be made based on technical ability, past performance, and price. These evaluation factors have equal levels of importance. For past performance evaluation, provide at least three (3) references of sources for whom you have provided the specified materials and/or service(s). The solicitation document and incorporated provisions and clauses are those in effect through FAC 2001-15. This is a one year requirement for Preventive and Corrective Maintenance from Oct 01, 2003 through Sep 30, 2004 as defined in the Statement of Work and CLINs that follow. STATEMENT OF WORK (WITH NO LOANER OPTION) GENERAL REQUIREMENTS: The effort required hereunder shall be performed in accordance with this Statement of Work and in accordance with all other terms and conditions set forth herein. The contractor shall provide all services, materials and equipment necessary for the repair/service of Kodak Dry View Processor and Kodak Ektascan Laser Printer located in the Radiology Department Naval Medical Center, San Diego (NMCSD) as identified in the following CLINs to ensure dependable and reliable equipment operation. The scope of work performed under these specifications includes the furnishing of all labor, and parts to perform all repairs on equipment listed, to assure continued operation at their designed efficiency and capacity. PREVENTIVE MAINTENANCE: 1) Perform service repair/maintenance to industry standards. 2)Insure that only FULLY QUALIFIED FIELD ENGINEERS and TECHNICIANS who have gone through original equipment manufacturer (OEM) or comparable third party service schools for the above mentioned equipment, shall be employed in the performance of any and all work performed under this contract. Upon request, the contractor shall provide training certificates (or notarized copies) to the Medical Repair Branch for verification. The highest standard of professional capability and electrical/mechanica1 workmanship is to be maintained throughout the life of this contract. 3) Make repairs to the extent necessary (as determined by inspection tests or disassembly) to ensure a functional system that will efficiently serve its intended purpose. CORRECTIVE MAINTENANCE: 1) Correct inoperable condition in a timely manner with a response time of no later than 30 minutes after telephone notification. Immediately upon contract award, the contractor will provide Medical Repair Branch an emergency telephone number. Contractor will respond no later than 24 hours after telephone notification. 2) Provide only the work necessary to restore the equipment to a serviceable/operating condition by adjustments, replacement parts, or minor repairs when it is determined that extensive repairs and parts replacements are not necessary. 3) Equipment improvements/modifications shall be made only upon Medical Repair Branch written approval and direction. 4) Notify the Medical Repair Branch immediately upon receipt of OEM or replacement parts/equipment safety recalls notices. 5) Insure that original design and functional capabilities will not be changed, modified, or altered unless the Medical Repair Branch authorizes such changes. 6) Provide suitable OEM recommended repair equipment/tools required for the satisfactory execution of all repairs made. 7) Furnish manufacturer OEM approved lubricants and lubricate wear points within the equipment. 8)Extend to the Government all commercial warranties on replacement parts, consistent with standard industry practices. 9) Maintain an adequate spare parts inventory. TITLE TO EQUIPMENT: The contractor shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof. LIABILITY: The contractor shall not be liable for any loss, damage, or delay due to any cause beyond his reasonable control including but not limited to, acts of government, strikes, lockouts, fire, explosion, theft, floods, riot, civil commotion, war, malicious mischief or acts of God. UTILITIES: The contractor may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract. The building engineer, to ensure compatibility with the Naval Medical Center's electrical wiring and equipment, must approve contractor electrical equipment. ACCESS TO EQUIPMENT: The contractor shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment. CONTRACTOR CHECK-IN/CHECK-OUT: The Contractor, or his representative, is required to report to the Medical Repair Branch for Visitor Badges during the hours of 0730 - 2000 hours, Monday through Friday, prior to and upon completion of any service/repair performed. FIELD SERVICE REPORTS: The contractor, or his representative shall furnish a legible copy of the Field Service Report upon completion of work performed to: GABRIEL G. SANTOS, Contract Administrator, Material Management Department, Biomedical Engineering Branch, Naval Medical Center, San Diego, Building 1, Ground Floor, Room GD-18H1, Phone: (619) 532-6320, Fax: (619) 532-8013, E-mail: ggsantos@nmcsd.med.navy.mil. The contractor, or his representative, shall complete the Government copy of this Field Service Report to include the following: 1) Date and Time Notified, 2) Date and Time Arrival, 3) ECN (Equipment Control Number), 4) Type, serial # and model #, 5) Time expended repairing/servicing, 6) Description of malfunction, 7) General Description of replaced parts and service performed, and 8)Comments as to cause of malfunction. FIELD SERVICE REPORTS ARE REQUIRED PRIOR TO APPROVAL OF ALL INVOICES. GOVERNMENT PERSONNEL: NMCSD employees will not perform maintenance or attempt repairs to equipment while such equipment is under the purview of this contract unless agreed to in writing by the contractor. PARTS AVAILABILITY: To ensure minimal equipment downtime, the contractor shall maintain replacement repair parts and materials necessary to perform each repair or supply said parts and materials within day. COMPENSATION: Labor: All compensation for labor is included in the contract price. Parts and materials: All compensation for parts and materials is included in contract price. Parts/Supplies Quality: Parts and Supplies provided under this contract shall be guaranteed to be equal in all respects, including performance, interchangeability, durability and quality to the OEM parts when new or as presently recommended by the manufacturer. PREVENTIVE MAINTENANCE AND CORRECTIVE MAINTENANCE SCHEDULES: Services will be required based upon the following schedules: PREVENTIVE MAINTENANCE: Two (2) times per fiscal year (October 2003 and April 2004), CORRECTIVE MAINTENANCE: Monday - Friday, 0800-1700 hrs. (End of Statement of Work). CLIN 0001: On-site full service maintenance contract on (4) government owned Kodak Dry View Laser Imagers and (10) components. CLIN 0001AA: Dry View Laser Imager, Serial Number: 8703076, Model Number: 8700D, K#: 41658264, ECN: 00259M30DD, Location: CT Division, Acquisition Cost: $ 57,590.00, QTY: 4 QTR (TIME); CLIN 0001AB: Dry View Laser Imager, Serial Number: 8705126, Model Number: 8700D, K#: 41658265, ECN: 00259M30C9, Location: Area 2, Diagnostic X-Ray, Acquisition Cost: $ 57,590.00, QTY: 4 QTR (TIME); CLIN 0001AC: Dry View Laser Imager, Serial Number: 8703077, Model Number: 8700D, K#: 41506757, ECN: 00259M2A98, Location: MRI Suite, Acquisition Cost: $ 57,590.00, QTY: 4 QTR(TIME); CLIN 0001AD: Dry View Laser Imager, MODEL NUMBER: 8700D,SERIAL NUMBER: 8705957,K#: 41631655,LOC: MRI SUITE,ECN: 00259M2AA2,ACQUISITION COST: $ 57,950.00, QTY: 4 QTR (TIME); CLIN 0001AE: MULTI-INPUT MANAGER, MODEL NUMBER: 8700E, SERIAL NUMBER: 002994, K#: 41506758, LOC: RADIOLOGY DEPT.,ECN: NIF, ACQUISITION COST: NIF, QTY: 4 QTR(TIME); CLIN 0001AF: 2 PRIMARY MODALITIES, MODEL NUMBER: 8800 MD, SERIAL NUMBER: 002994, K#: 41506758, LOC: RADIOLOGY DEPT., ECN: NIF, ACQUISITION COST: NIF, QTY: 4 QTR(TIME); CLIN 0001AG: 2 Secondary Consoles, Model Number: 8800SC, Serial Number: 002994, K#: 41506758, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001AH: Dryview Multi-input Manager, Model Number: 8800, Serial Number: 002670, K#: 41658266, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001AJ: 3 Primary Modalities, Model Number: 8800 MD, Serial Number: 002670, K#: 41658266, LOC: Radiology Dept, QTY: 4 QTR(TIME); CLIN 0001AK: 9400 Print Server For Dicom, Model Number: 9400P, Serial Number: 100645, K#: 100645, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001 AL: 9400P Print Server For Dicom, Model Number: 9400P, Serial Number: 100218, K#: 100,218, LOC: Radiology Dept, QTY: 4 QTR(TIME); CLIN 0001AM: Multi Input Manager, Model Number: 8800, Serial Number: 002046, K#: 41658262, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001AN: Primary Modalities, Model Number: 8800MD, Serial Number: 002046, K#: 41658262, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001 AP: (1) Secondary Console, Model Number: 8800SC, Serial Number: 002046, K#: 41658262, LOC: Radiology Dept., QTY: 4 QTR(TIME); CLIN 0001AQ: Print Server For Dicom, Model Number: 8800SC, Serial Number: 100505, K#: 100505, LOC: Radiology Dept., QTY: 4 QTR(TIME);CLIN 0002: 8700N Dryview Laser ? PACS, Model Number: 8700N, Serial Number: 8710303, K#:1665740, LOC: Area 4, Radiology Dept., QTY: 4 QTR(TIME). This acquisition incorporates the following FAR clauses: 52.212-1 Instruction to Offers- Commercial Item (Oct95); 52.212-3 Offeror representations and certification - Commercial Items (Oct95) must be completed and submitted along with the quote (Please contact Kohala Hembre by fax to (619) 532-5596 or e-mail to kohembre@nmcsd.med.navy.mil if a copy is needed) in accordance with 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items (Aug96). The following clauses are incorporated by reference in paragraph (a): 52.233-3 Protest after Award (31 U.S.C. 3533) paragraph (b), 52.222-21 Prohibition of Segregated Facilities (Feb 1999), 52.222-26 Equal Opportunity (E.O.11246), 52.222-35 Affirmative Action for Special Disabled and Vietnam ERA Veteran (28U.S.C.4212), 52.222-37 Employment Reports on Special Disabled Veterans and Veterans of the Vietnam ERA (38 U.S.C.4212), 52.222-36 Affirmative Action for Handicapped Workers (29 U.S.C. 793), 52.212-4 Contract terms and conditions Commercial Items (OST 95), 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration (31 U.S.C. 3332), 52-232-7003 Electronic Submission of Payment Requests (Mar 2003), 52.237-2 Protection of Government Buildings, Equipment, and Vegetation, 52.252-2 Clauses Incorporated by Reference (Feb 1998), DFARS 252.204-7004, Required Central Contractor Registration (MAR 1989), DFARS 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Order Applicable to Defense Acquisitions of Commercial Item (APR2003).
- Place of Performance
- Address: NAVAL MEDICAL CENTER SAN DIEGO, 34800 BOB WILSON DRIVE, SAN DIEGO, CA
- Zip Code: 92134
- Country: USA
- Zip Code: 92134
- Record
- SN00437616-W 20030920/030918213315 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |