- Description
- NA Question and Answers from Site Visit held on 22 September 2003 at 1000 am. DACA72-03-T-0017 Security System Upgrade 1. Is the system digital ? YES 2. Do you want to display on a pc based SVGA/XGAmonitor or on a ntsc/ television set (analog) 3. Is this system going to be inside of one building or spread out over the base are you specifying source PELCO/Panasoinc/CBC 4. Are you open to all equal or superior products/solutions ? YES 5. We will supply all models/specs/features/gsa pricing and contract numbers ? are you interested in a solution as well as specific quoted prices ? 6. How many cameras are there total ? 12 7. How many are PTZ ? 1 8. How many are fixed ? 11 both daytime and night time 9. Do you want to connect all of the cameras to a central control using a fiber backbone in the ground ? FIBER ALREADY IN PLACE. 10. Will the contractor have to bore, trench, lay conduit, or internal panduit ? NO 11. Will the government provide the fiber backbone ? SEE QUESTION # 9 ABOVE 12. I yes to any of the above...what is the exact total in feet from each of the ??? cameras to the exisiting base fiber backbone? 13. What is the required latency...from each camera to the computer desktop (SVGA/XGA Monitor? in the master control center 14. Do you want the video to travel from the camera to the computer desktop in under 250 milliseconds 500 milliseconds 2000 milliseconds 4000 milliseconds ? YOU NEED TO PROVIDE US WITH THAT INFORMATION 15. Do you want automated joystick control by intelligence applications on a pc rather than rely on the manual joystick control that a operator must make 7x24x365 ? Would you like to have both manual joystick and automated (pc intelligent ptz control)? YOU NEED TO PRESENT YOUR OPTION. 16. Can we present an option for intelligent access control ? YES 17. Are there any lights at all for the ptz cameras ? YES 18. Can we assume all cameras are to be displayed simultaneously on one vga/xga large monitor in the resource control center...if it is 5 cameras, can we play all simultaneously on one BARCO 42 inch LCD ? ALL CAMERAS ARE SHOULD ON A 21 inch MONITOR AND TH E CAMERAS IN THE CASEY BUILDING ARE SHOULD ON ANOTHER MONITOR. 19.Will archiving/storage of the video be required ? YES, BACKUP ON CD. 20. If so for how long 30 days 90 days ? 30 21. Will you want digital asset management for the storage ? NO 22. Will any other operators on the local area network need to see the stored video files or the near real time transport streams ? NO 23. Due date for the proposal is scheduled for September 25th, which is an extremely short turn around time - any possibility of an extension, so that you may enjoy the benefit of competitive bids ?NO 24. If we do not represent, and/or are not certified, on the access control system that you presently have, we would not be in a position to provide you with a competitive bid - What is the brand of the card access s ystem, that you presently have ? NORTHERN 25. Is it presently covered under warranty and/or a service agreement with another vendor? WARRANTY 26. You make no mention of warranty, training, date of completion, etc. for this Upgrade - What will the contractual obligations be, for warranty, training, length of time for completion, etc.? MINOR TRAINING ON ADDITION TO PRESENT SYSTEM FOR VIDEO BADGIN G TO ACCESS SYSTEM.
- Place of Performance
- Address: US Army Humphreys Engineer Center Support Activity - Military ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
- Zip Code: 22315-3860
- Country: US
- Zip Code: 22315-3860
- Record
- SN00439383-W 20030924/030922213320 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |