Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 22, 2003 FBO #0694
MODIFICATION

28 -- carriage, bleed valve

Notice Date
10/20/2003
 
Notice Type
Modification
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, Tinker OC-ALC - (Central Contracting), 3001 Staff Drive, Ste 1AG76A, Tinker AFB, OK, 73145-3015
 
ZIP Code
73145-3015
 
Solicitation Number
F34601-04-R-55111
 
Response Due
12/5/2003
 
Archive Date
12/20/2003
 
Point of Contact
Stephen Yates, Contract Negotiator, Phone 405 734 8769, Fax 405 734 8776,
 
E-Mail Address
stephen.yates@tinker.af.mil
 
Description
OC-ALC/LPKBA DIR CONTRACTING/PROPULSION 3001 STAFF DR STE 1AC1/112A TINKER AIR FORCE BASE OK 73145-3032 This is an amendment to the noticed dated 16 OCT 2003 The solicitation number is corrected to read FA8104-04-R-55111 C-ALC/LPKBA DIR CONTRACTING/PROPULSION 3001 STAFF DR STE 1AC1/112A TINKER AIR FORCE BASE OK 73145-3032 28?Carriage,Bleed Valve SOL F34601-04-R-55111 DUE 05 DEC 2003 OC-ALC/PKXDA TINKER AFB OK 73145-3015, For additional information contact Stephen Yates/LPKBA/ [405] 734-8769 Item 0001 NSN: 2840-01-192-5347NZ P/N: 4061355, Predominant Material: Nickel alloy. Dimensions: 2.478 ?2.480 in X 0.800 in diameter. Function: Item is part of the Comp. Bleed used in the start cycle. Applicable to: F100/200/220E Engine. Destn: Tinker Air Force Base Ok 73145-3032. Quantity ranges: 1 to 84, 85 to 168, 169 to 252. Delivery: 42 per month starting Jun 04 or before. FIRST ARTICLE REQUIREMENT for non- approved sources or those that have not delivered within 3 years. This is a source-controlled item. Only sources listed are qualified. Sources must be qualified prior to being considered for award. The solicitation will contain instructions for obtaining further information on this requirement. The requirements of FAR 9.2021(a) have been completed and copies of the qualification requirements and standards may be obtained as described in the solicitation. These qualification requirements apply to line item(s) 0001. Award will be made only if the offeror meets qualification requirements at the time of award in accordance with FAR 52.209-1. Award will not be held in abeyance pending qualification of other sources. The approximate issue date will be 05 NOV 2003. Written procedure will be used for this solicitation. To: United Technologies Corp, East Hartford Ct 06118-1888, Empire Mfg Corp, Bridgeport CT 06604. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quotation, which shall be considered. Specifications, plans, or drawings relating to the procurement described are incomplete or not available and cannot be furnished by the Government. Note: An Ombudsman has been appointed to hear concerns from offerors or potential Offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the Ombudsman at (405) 736-3273. DO NOT CALL THIS NUMBER FOR SOLICITATION REQUESTS. Note: Faxed solicitation requests can be submitted to OC-ALC/PKXDA, Tinker AFB OK 73145-3015, FAX NUMBER (405) 739-3656. See Note (s) 23,26.
 
Record
SN00454704-W 20031022/031020213349 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.