Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 08, 2004 FBO #0864
SOURCES SOUGHT

61 -- Electrical Workers Test Equipment

Notice Date
4/6/2004
 
Notice Type
Sources Sought
 
NAICS
221112 — Fossil Fuel Electric Power Generation
 
Contracting Office
Other Defense Agencies, Coalition Provisional Authority, Republican Presidential Compound, Republican Presidential Compound APO, Baghdad, Iraq, AE, 09335
 
ZIP Code
09335
 
Solicitation Number
Reference-Number-W914NS-04-RFI-2364
 
Response Due
4/13/2004
 
Archive Date
4/28/2004
 
Point of Contact
Wanda Cross, Contracting Officer, Phone 703-343-9225, Fax null,
 
E-Mail Address
crossw@orha.centcom.mil
 
Description
DO NOT CONTACT WANDA CROSS REGARDING THIS NOTICE, SEE NOTE BELOW. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a Sources Sought synopsis, Request for Information only. The purpose of this synopsis is to gain knowledge of interested and potential qualified sources and their size classifications relative to North American Industrial Classification System (NAICS) Codes 221112 and 221122. This synopsis is being posted to FedBizOps and the Coalition Provisional Authority (CPA) site located at http://iraqcoalition.org/business_center.html. The Coalition Provisional Authority is seeking sources that can provide Electrical Workers Instruments as described below with delivery 30 days after date of contract and delivery within 20 miles of the Baghdad International Airport. Response to this Sources Sought synopsis will be used by the CPA to make appropriate determinations about potential sources only. The information received will be used as part of a market survey. After review of the response to this request for information, a solicitation announcement may be published at a later date on FedBizOps and the CPA?s Business Opportunities website (http://iraqcoalition.org/business_center.html) . When responding, please reference sources sought announcement number W914NS-04-RFI-2364, and include company name, address, telephone number, internet address, point of contact, business size pursuant to the NAICS, and specific information regarding your ability to provide the equipment described below. This is not a request for proposals or quotations and in no way obligates the CPA to award any contract. Interested sources are requested to submit response to Charles D. Cluck by email at cluckc@orha.centcom.mil . Telephone or faxed responses will not be accepted. Questions shall be submitted in writing to the same. Response to this inquiry will not be considered either as an offer or as any kind of response to any future solicitation that may or may not be issued for the material in Attachment I. All interested offerors will have to respond to the solicitation announcement in addition to responding to this request for information. No solicitation is currently available. If you are interested in participating in any future solicitation for these requirements, your response to this request for information is due April 13, 2004, by 8:00 A.M. Baghdad Time. ************************ (1) HIGH VACUUM OIL PURIFIER (3,500 L/HR) ? Specially developed for the treatment of transformer insulating oil by the combined action of filtration and evaporation in a high vacuum environment. Semi-mobile trailer complete with spare parts for fine filter cartridges. Suggested brand name type or like type/model: None. 14 ea. ***(2) HIGH VACUUM OIL PURIFIER (2,500 L/HR) ? Specially developed for the treatment of transformer insulating oil by the combined action of filtration and evaporation in a high vacuum environment. Semi-mobile trailer complete with spare parts for fine filter cartridges. Suggested brand name type or like type/model: None. 14 ea. ***(3) PRIMARY CURRENT INJECTION SET ? Portable current injection set for testing primary circuit with suitable cables for high current injection. Inlet: 2 phase, 416 Volt, 50 Hz. Outlet: 100 ? 400 ? 1500 ? 3000 amps. Accessories: Cables with suitable clamps. Suggested brand name type or like type/model: None. 30 ea. ***(4) SECONDARY CURRENT INJECTION SET ? Relay testing unit. Inlet: 220 Volt, 50 Hz. Current: 0 ? 10 ? 100 amps with coarse and fine adjustments. Voltage: 0 ? 250 Volt (AC/DC), Electronic timer stopped through make/break contact. Suitable accessories. Suggested brand name type or like type/model: None. 30 ea. ***(5) INSULATION TESTER (MEGGER 5,000 VOLT) ? Ranges: 5000 ? 2500 ? 1000 ? 500 Volt. Energized by push button and batteries. Scale ranges: 0 ? 50 Mohm, 40 ? 200 Mohm, and 200 ? 10000 Mohm. Suggested brand name type or like type/model: None. 100 ea. ***(6) TRANSFORMATION RATIO TESTER The transformer ratio shall be determined by abridge measurement, single and three phase models. Measuring ranges: 1 ? 1000 ohms. Power source: 220 V, 50 Hz. Suggested brand name type or like type/model: None. 30 ea. ***(7) EARTH RESISTANCE METER ? For measuring earth resistance and earth resistivity. Measuring ranges 0 -9.99 kohm. Electronic type energized by push button and batteries. Complete accessories required. Suggested brand name type or like type/model: None 30 ea. ***(8) OIL DIELECTRIC STRENGTH TESTER ? Automatic and semi-automatic voltage increase (Alternative ? Programmable). Rate of voltage rise: 0.5 ? 3 kV/sec. Supply voltage: 220 Volt, 50 Hz. Output voltage RMS between electrodes: 10 ? 70 kV. Switching by push-buttons (Supply ?ON?, and HV ?ON?). Complete accessories. Suggested brand name type or like type/model: None. 30 ea. ***(9) AVO METER ? Digital multi-meter (Alternative ? with temperature probe). Current: 0 ? 10 Amp (AC/DC). Voltage: 0 ? 700 Volt. Resistance: 0 ? 30 Mohm. Suggested brand name type or like type/model: None. 100 ea. ***(10) CLAMP METER ? For current measurements ? analogue scale (Alternative ? Digital reading). Ranges: 0 -10 ? 30 ? 100 ? 3000 amps, 0 -700 Volt (Alternative 0 kVar, kW, Power factor. Measuring clamp on meter. Suggested brand name type or like type/model: None. 500 ea. ***(11) HIGH TENSION AC/DC TESTER ? Portable tester of output voltages continuously adjustable. Voltage: DC ? 0 ? 80 kV, AC ? 0- 80 kV RMS. Supply voltage: 220 Volt, 50 Hz. Operating unit, current limitation unit. Accessories: Discharge rod (750 kohm connecting high voltage cable for testing. Suggested brand name type/model: None. 100 ea. **********DO NOT CONTACT WANDA CROSS REGARDING THIS NOTICE. THE POINT OF CONTACT IS CHARLES D. CLUCK, email cluckc@orha.centcom.mil, TEL 703-343-9219.
 
Place of Performance
Address: DO NOT CONTACT WANDA CROSS REGARDING THIS NOTICE. THE POINT OF CONTACT IS REPEATED FOR YOUR INFORMATION: THE POINT OF CONTACT IS CHARLES D. CLUCK, email cluckc@orha.centcom.mil, TEL 703-343-9219.
Country: Iraq
 
Record
SN00561175-W 20040408/040406212703 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.