Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 16, 2004 FBO #0872
SOLICITATION NOTICE

66 -- Multi-channel Potentiostat/Galvanostat

Notice Date
4/14/2004
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Navy, Naval Sea Systems Command, NUWC Division Newport, Simonpietri Drive, Newport, RI, 02841-1708
 
ZIP Code
02841-1708
 
Solicitation Number
N66604-04-Q-2437
 
Response Due
4/20/2004
 
Archive Date
5/5/2004
 
Point of Contact
Nancy Teasdale, Contract Negotiator, Phone 401-832-1898, Fax 401-832-4820, - Lisa Brazil, Contract Negotiator, Phone 401-832-1437, Fax 401-832-4820,
 
E-Mail Address
teasdalena@npt.nuwc.navy.mil, brazillm@npt.nuwc.navy.mil
 
Description
The Naval Undersea Warfare Center Division Newport RI intends to award a contract with firm fixed price provisions under FAR parts 12 and 13 procedures (commercial items; simplified acquisition procedures), for a multi-channel potentiostat/galvanostat. Quantity of 1. Award to be made to the responsible offeror proposing the lowest price. Anticipated RFQ date is: 14 APR 2004. Unrestricted. F.O.B. Destination to NUWC Newport, RI. Delivery: JUN 2004. Specifications: Minimum of 4 independent potentiostat/galvanostat channels; Independent potential and current control on each channel with simultaneous current and voltage measurement; Capable of 2,3, 4 or 5 terminal measurements on each channel; Configurable as N-stat with one counter and one reference electrode with multiple working electrodes; 2 auxiliary inputs on each channel with programmable ranges of plus/minus 2.5 V, plus/minus 5 V, and plus/minus 10 V; TTL signal in and out to enable experiments to coordinate precisely with other instrumentation; Data buffer retains data even if PC is disconnected; Automatic current ranging on each channel from 10 microamps to 1 amps; Impedance measurement capability on each channel capable of executing a 40 data point experiment between 100 kilohertz and 0.1 hertz in less than 90 seconds; 20 V compliance with programmable ground on each channel; Autocalibration for each channel; Data acquisition system including all hardware and software necessary to control the potentiostat/galvanostat, acquire the data from the instrument, and analyze the experimental data; Full suite of electrochemical experiments including: Open circuit voltage measurement; Chronoamperometry/Chronocoulometry with multiple potential steps within the same experiment; Chronopotentiometry with 9999 current steps where voltage and charge cutoffs signal next step; Cyclic voltammetry; Electrochemical impedance spectroscopy with analysis (equivalent circuit) software; Galvanostatic cycling with potential limitation; Differential pulse voltammetry; Battery (galvanostatic cycling with potential limitation and potentiodynamic cycling with galvanostatic acceleration); Manual control of current and potential; Modular potentiostatic and galvanostatic experiments which allow the user to perform potentiostatic/ potentiodynamic or galvanostatic/galvanodynamic, respectively, within a single experiment; Graphics capability including monitoring of experiments in progress; User friendly, windows based software package that does not require training for an experienced electrochemist. Cell Control: A voltage range of 20 Volts (V), adjustable from plus/minus 10V or 0 - 20 V; Maximum potential resolution 300 microvolts on 20 V dynamic range; Current resolution: 0.004 % of the dynamic range; Accuracy (DC): less than 0.1% full scale range; Rise time: less than 2 microseconds (no load); Slew rate: greater than 3V/microseconds (no load). Current measurement and control: Converter: 16 bits ADC; Current ranges: plus/minus 10 microamps, plus/minus 100 microamps, plus/minus 1 milliamps, plus/minus 10 milliamps, plus/minus 100 milliamps, plus/minus 250 milliamps, up to 1 amps; Accuracy (DC) less than 0.1 % full scale range. Potential measurement: Ranges: plus/minus 2.5 V, plus/minus 5 V, plus/minus 10 V, and plus/minus 10 V adjustable DC shift level; Maximum resolution: 0.0015 % of the range down to 75 microvolts; Acquisition speed: 10,000 samples / second; Accuracy (DC): less than 0.1 % full scale range. Impedance: Frequency range: 10 microhertz to 200 kilohertz (minimum); Impedance measurement capability on each channel capable of executing a 40 data point experiment between 100 kilohertz and 0.1 hertz in less than 90 seconds. Additional inputs/outputs: Two general purpose analog inputs: 16 bits resolution with programmable range plus/minus 2.5 V, plus/minus 5 V, plus/minus 10 V. Current output at least 1 A per channel. NAICS: 334516. Our department no longer issues solicitations or amendments in paper form. Instead, they may be accessed at our web site http://www.npt.nuwc.navy.mil/contract/. We also provide electronic access in our Bid Room.
 
Record
SN00565926-W 20040416/040414212429 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.