44 -- RFQ ON INDUSTRIAL TYPE FURNACE

Notice Date
5/4/2004
 
Notice Type
Solicitation Notice
 
Contracting Office
M62204 Barstow, CA
 
ZIP Code
00000
 
Solicitation Number
M938044113102
 
Response Due
5/11/2004
 
Archive Date
6/10/2004
 
Point of Contact
LYNNE HARTSHORN 7605776248 DAVID REEVES e-mail: reevesda@barstow.usmc.mil
 
E-Mail Address
Email your questions to LYNNE HARTSHORN
(hartshorn@barstow.usmc.mil)
 
Description
NAICS 333994 - FURNACE, INDUSTRIAL TYPE: (AN RFQ IS REQUESTED ON BRAND NAME OR EQUAL, L&L SPECIAL FURNACE CO INC, ACCESS www. hotfurnace.com FOR ANY ADDITIONAL COMPARISON INFORMATION.) THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN SUBPART 12.6, AS SUPPLEMENTED, WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSITUTES THE ONLY SOLICITATION; PROPOSALS ARE BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED. ALL RESPONSIBLE SOURCES MAY SUBMIT A QUOTE WHICH WILL BE CONSIDERED BY THE AGENCY. QUOTE MUST BE A PACKAGE PRICE, ALL OR NONE, TO INCLUDE BRAND NAME OR EQUAL WITH REQUIRED OPTIONS AS LISTED BELOW. GENERAL DESCRIPTION: BRAND NAME: L&L SPECIAL FURNACE CO INC MODEL FB 555 PLUS OPTIONS LISTED, OR EQUAL. The welding shop at MCLB Maintenance Center needs a large heating fur nace to heat a variety of metals and castings before and after the welding process. Due to stresses placed upon various metals by the welding process, pre heating and /or a controlled cool down is essential to keep the metals from developing stress cracks. The desired size, temperature range and salient features are described as follows; Internal working dimensions: W 60" H 60" D 60" Load bearing capacity: Minimum 1500 lbs. Heat range: 0-2000 deg. F. Accuracy: Plus or minus 50 deg. above 1500 deg. F. Power source: Electric Furnace must be equipped with a vertical access door, complete with a pneumatic foot-activated switch, and safety locks to prevent door opening while furnace is operating. Furnace requires electronic controls, complete with timer and digital display. Furnace must be insulated with ceramic fiber lining. (See List of Options). (IT IS ADVISED THAT A GENERAL DIMENSION DRAWING , SPECIFIC TO THE FURNACE, BE PROVIDED AFTER ORDER IS PROCESSED BY AN ENGINEERING STAFF, TO SHOW ALL REQUIRED CLEARANCES AND IMPORTANT DIMENSIONS.) UTILITY REQUIREMENTS: VOLTAGE: 480/3/60; KW: 157 LIST OF OPTIONS REQUIRED (BRAND NAME OR EQUAL): Insulation Modules 1" NPT Uniformity Survey Port Manually Operated Counterbalanced Vertical Door with Hank Crank, Roller Chain, Sprockets and Plug Door Pneumatic Operation for Vertical Door Floor Switch to Actuate Vertical Door 18" Air Cooled Alloy Fan with 2 HP Motor, Heat Slinger, Bearings and OSHA Cover Atmosphere Fan Seal with Packing Gland Iron-Aluminum-Chrome Alloy Elements Castable Piers for Loading Right Side Mounted NEMA 1 Panel with Gasketed Hinged Door Single Point Power Connection to Control Panel Door Cut Off Switch to Turn Off Power to the Elemen ts when the Door is Opened Complete Branch Fusing of All Control and Power Circuits Lighted NEMA 13 On/Off Switch Control Transformer to Provide 120 volts to the Control Circuit THHN Power Wire (rated for 105*C) Honeywell UDC 3300 Digital 12 Segment Program Control (.25% accuracy) 6 Ramps/6 Soaks/Single Program Honeywell UDC 2300 Digital High Limit Control with Programmable Max Temperature & Back Up Contactors Event Alarm with Silencer Circuit Shielded Thermocouple Connection Wire and careful grounding to avoid electrical noise Type K Open Type Chromel/Alumel Thermocouples Mercury Power Contactors (with fast cycle time and quiet operation) Two Zones of Control (Top and Bottom) PACKAGE PRICE TO INCLUDE: START UP SERVICE AND ON-SITE TRAINING, ALL REQUIRED TRAVEL AND LIVING EXPENSES PAID. TWO SETS OF OPERATOR MANUALS ARE REQUIRED. ONE OR MORE YEARS? WARRANTY; IT IS REQUESTED THAT WARRANTY BE ACTIVATED AT TIME OF INSTALLATION (SEPTEMBER/OCTOBER 2004 TIMEFRAME). INSPECTION AND ACCEPTANCE F.O.B. DESTINATION. PROVISIONS AND CLAUSES INCORPORATEDED BY REFERENCE: 52.212-1, INSTRUCTIONS TO OFFERORS-COMMERCIAL 52.212-2, EVALUATION-COMMERCIAL ITEMS 52.212-3, OFFEROR REPRESENTATIONS AND CERTIFICATIONS-COMMERCIAL ITEMS 52.212-4, CONTRACT TERMS AND CONDITIONS-COMMERCIAL ITEMS 52.212-5, CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS-COMMERCIAL ITEMS EVALUATIONS WILL BE DONE IN ACCORDANCE WITH THE CRITERIA SET FORTH IN THIS SOLICITATION. DETERMINATION WILL BE MADE BASED ON TECHNICAL, PRICE AND/OR BEST VALUE TO THE GOVERNMENT AND PAST PERFORMANCE , RESPECTIVELY. OFFERORS ARE TO FILL IN THE APPLICABLE AREAS IN 52-212-3 AND SUBMIT WITH THE RFQ. E-MAIL QUESTIONS: mailto:hartshornl@barsto w.usmc.mil
 
Record
SN00579872-W 20040506/040504212753 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.