SOLICITATION NOTICE
Y -- REPAIRS AND ADDITION TO PUSAN PISTOL RANGE
- Notice Date
- 7/6/2004
- Notice Type
- Solicitation Notice
- NAICS
- 238910
— Site Preparation Contractors
- Contracting Office
- Department of the Navy, Naval Facilities Engineering Command, Engineering Field Division, South, ROICC Beaufort, P. O. Box 9310, Beaufort, SC, 29904-9310
- ZIP Code
- 29904-9310
- Solicitation Number
- N62467-04-R-9151
- Response Due
- 7/21/2004
- Archive Date
- 8/5/2004
- Point of Contact
- Alberta Abram, Contract Specialist, Phone 843-228-8575, Fax 843 228 8590, - Robin Fowler, Supervisor, Phone 843-228-8567,
- E-Mail Address
-
alberta.abram@navy.mil, robin.fowler@navy.mil
- Description
- Proposed contract N62467-04-R-9151, REPAIRS AND ADDITION FO PUSAN PISTOL RANGE, MARINE CORPS RECRUIT DEPOT, PARRIS ISLAND, SC, listed herein is being considered for 100% 8(a) or HUBZone Set-Aside. All interested 8(a) or HUBZone concerns will notify this office via email of their intention to submit a proposal on the proposed contract as Prime no later than 21 JULY 2004. NOTE: 8(a) and HUBZone firms: This notification/submittal MUST include (1) the name, address, and small business size status of the firm; (2) past performance references; (3) evidence of experience in the construction of similar size and complexity (construction costs between $1,000,000 and $5,000,000); The project information shall include, at a minimum, the following information: (i) the contract name or number, completion date of the project, and the total cost of the project; (ii) the names and telephone numbers of the facility or installation for whom the work was performed; (iii) the name and telephone number of a supervisory level point of contact at each facility or installation who has knowledge of the performance of the entity or entities. If adequate interest is not received from 8(a) concerns, consideration will then be given to setting the requirements aside for HUBZone concerns. If adequate interest is not received from HUBZone concerns, then the requirement will be issued unrestricted. Also, if adequate interest is received from 8(a) and HUBZone concerns, it is the Contracting Officer's determination on how this will be set-aside IAW SBA Procedures. The work includes all incidental related work to provide a complete and usable project for the following: Repair: Removal and disposal of lead bullets from existing berm; Repairs to CMU wall barrier wall; Repair and restore existing concrete bases and walkways and CMU walls with earth berm; Seal cracks in concrete floor; Remove and replace light fixtures; Clearing and grubbing, grading and grassing. Head No. 789: Removal and replacement of existing doors, partition walls, plumbing fixtures and connected utility lines and lighting fixtures; and other incidental work. Improvements and addition: Remove existing CWU wall and provide new CMU wall to extend range bringing the total number of firing positions to 48. Provide infrastructure for new targets and their controls to be installed by a target system contractor. Extend existing shelter and add new control room. Provide new lighting fixtures for new shelter and for new target system; Provide new sheet pile and construct berm; and other incidental work. NAICS is 238910: Site Prep Contractors and Size Standard is $12M. All interested 8(a) Set-Aside or HUBZone Set-Aside concerns will notify this office via email to alberta.abram@navy.mil no later than JULY 21, 2004. YOUR RESPONSE MUST include the requirements (1) through (3) listed above.
- Place of Performance
- Address: MCRD/ERR, PARRIS ISLAND, SC
- Zip Code: 29904
- Zip Code: 29904
- Record
- SN00615681-W 20040708/040706211944 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |