Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 14, 2004 FBO #0992
SOLICITATION NOTICE

65 -- Retinal Thickness Analyzer (RTA), Diagnostic Imaging device

Notice Date
8/12/2004
 
Notice Type
Solicitation Notice
 
Contracting Office
Attn: Department of Veterans Affairs, VISN 3 Network Acquisition Program, (00BSC), 130 West Kingsbridge Road, Bronx, New York 10468-3992
 
ZIP Code
10468-3992
 
Solicitation Number
10N3-279-04
 
Response Due
8/31/2004
 
Archive Date
9/30/2004
 
Point of Contact
Point of Contact - Joshua Ross, Contract Specialist, Ph: (718) 584-9000 ext. 4320, Fx:(718) 741-4722, Contracting Officer - Joshua Ross, Contract Specialist, Ph:(718) 584-9000 ext. 4320, Fx:(718) 741-4722
 
E-Mail Address
Email your questions to Joshua Ross
(joshua.ross@med.va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
VA New Jersey Healthcare System, Lyons Campus, Acquire: Retinal Thickness Analyzer (RTA), Diagnostic Imaging device Place of Performance is Department of Veterans Affairs Medical Center, 385 Tremont Ave, East Orange NJ 07018 Specifications: Equipment to be provided must be equal or comparable to Talia Technologies RTA: Description: Performance Retinal Thickness Analyzer (RTA), Diagnostic Imaging device that provides direct cross sectional images of the retina for the mapping and quantative measurement of retinal thickness and disk topography. Provides objective look at the optic disc, posterior pole and peripapillary and creates 2D and 3D color topography and thickness maps, deviation probability maps from a normative database and quatative numerical values. Provides ability to compare, exam, and objectively track the progression of patient condition. Multiple diagnostic capability and clinical application in Glaucoma, Diabetic Macular Edema, Cystoid Macular Edema, Age-related Macular Degeneration, and enhance visualization of various retinal pathologies, such as macular holes, macular cysts, and membranes. retinal digital imaging system ( digital fundus camera) providing digital fundus photographs and storage capability. Technical Technical Specification must similar to but not less than: Illumination Source HE-NE Laser, 543.3 NM, 0.0180 Class II Laser device Scanning characteristics 5-13 RTA Scans, At each Scan 16 Optical Cross sections covering a 3 x 3 mm area on the retina Acquisition time 0.3 Sec Per Scan, 3-5 Min Total Patient examination Measurement area Posterior 21 Degree x 21 Degree Perperipapillary 15 degree X 21 Degree Optic Disc 10 Degree x 10 degree Data Acquisition (Thickness) in the macula 80 cross sections Total of 2560 data points Data acquisition (Topography) In the disc area 48 cross sections Total 3072 data points Reproducibility Mean foveal thickness: 8.8 mm at a given point 13 mm Resolution Depth (Axial) Resolution: 52mm Lateral (Transverse) resolution: 12 mm along the slit To include INSTALLATION, TRAINING & SET-UP.
 
Web Link
RFQ 10N3-279-04
(http://www.bos.oamm.va.gov/solicitation?number=10N3-279-04)
 
Place of Performance
Address: 151 Knollcroft Road Lyons, NJ
Zip Code: 07939
Country: United States
 
Record
SN00642364-W 20040814/040812211932 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |