SOLICITATION NOTICE
28 -- Augmentor Support
- Notice Date
- 8/31/2004
- Notice Type
- Solicitation Notice
- NAICS
- 336412
— Aircraft Engine and Engine Parts Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, Tinker OC-ALC - (Central Contracting), 3001 Staff Drive, Ste 1AG76A, Tinker AFB, OK, 73145-3015
- ZIP Code
- 73145-3015
- Solicitation Number
- FA8104-05-R-54003
- Response Due
- 10/20/2004
- Archive Date
- 11/3/2004
- Point of Contact
- Stephen Yates, Contract Negotiator, Phone 405 734 8769, Fax 405 734 8776, - Joleeta McClish, Contract Negotiator, Phone 405-734-8766, Fax 405-734-8776,
- E-Mail Address
-
stephen.yates@tinker.af.mil, joleeta.mcclish@tinker.af.mil
- Description
- OC-ALC/LPKBA DIR CONTRACTING/PROPULSION 3001 STAFF DR STE 1AC1/112A TINKER AIR FORCE BASE OK 73145-3032 28?SUPPORT, AUGMENTOR SPRAY MANIFOLD SOL FA8104-05-R-54003 DUE 20 OCT 2004 OC-ALC/PKXDA TINKER AFB OK 73145-3015, For additional information contact Stephen Yates/LPKBA/ (405) 734-8769 Item 0001 NSN 2840-01-335-7570NZ, P/N: 4073586. Size: 4.595 inches min to 4.615 inches max length. Form/Fit/Function: Item secures the Segment IV Spray Manifold to the F100 engine. Predominant Material AMS 5544-Nickel Alloy. Quantity Ranges 1-534, 535-1067,1068-1601 each. Applicable to: F100PW100/200/220/220E Engine. Destn: Tinker Air Force Base Ok 73145-3032. Delivery: 266 per month to start Jun 05 or before. FIRST ARTICLE REQUIREMENT for non-approved sources or those that have not delivered within 3 years. This is a source- controlled item. Only sources listed are qualified. Sources must be qualified prior to being considered for award. The solicitation will contain instructions for obtaining further information on this requirement. The requirements of FAR 9.202(A) have been completed and copies of the qualification requirements and standards may be obtained as described in the solicitation. These qualification requirements apply to line item(s) 0001. The approximate issue date will be 20 SEP 2004. Written procedure will be used for this solicitation. To: United Technologies Corp, East Hartford Ct 06118-1888 and Dynamic Gunver Technologies Manchester, CT 06040. No telephone requests. Only written or faxed requests received directly from the requestor is acceptable. All responsible sources solicited may submit a bid, proposal, or quotation, which shall be considered. Award will be made only if the offeror, the product/service, or the manufacturer meets qualification requirements at the time of award in accordance with FAR clause 52.209-1. Award will not be held in abeyance pending qualification of other sources. Potential sources are not to utilize intellectual property of third parties without appropriate authorization of the intellectual property owner. Potential sources are cautioned that no part of the Government qualification requirement is intended to endorse or encourage the improper use of intellectual property developed by the Original Equipment Manufacturer of any other third party. The solicitation identifies the office where additional information can be obtained concerning qualification requirements as cited in each individual solicitation. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contact with the firm(s) listed. Specifications, plans, or drawings relating to the procurement described are incomplete or not available and cannot be furnished by the Government. Note: An Ombudsman has been appointed to hear concerns from offerors or potential Offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the Ombudsman at (405) 736-3273. DO NOT CALL THIS NUMBER FOR SOLICITATION REQUESTS. Note: Faxed solicitation requests can be submitted to OC-ALC/PKXDA, Tinker AFB OK 73145-3015, FAX NUMBER (405) 739-3656. See Note (s) 23,26.
- Record
- SN00662186-W 20040902/040901034917 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |