Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 22, 2004 FBO #1031
MODIFICATION

41 -- Water Cooled Centrifugal Chiller

Notice Date
9/20/2004
 
Notice Type
Modification
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Combat Command, 55 CONS, 101 Washington Sq Bldg 40, Offutt AFB, NE, 68113-2107
 
ZIP Code
68113-2107
 
Solicitation Number
FA4600-04-T-0195
 
Response Due
9/22/2004
 
Archive Date
10/7/2004
 
Point of Contact
Lee Smales, Contract Specialist, Phone 402-232-5930, Fax 402-294-4069,
 
E-Mail Address
lee.smales@offutt.af.mil
 
Description
Questions and Answers for solicitation FA4600-04-T-0195. No further questions will be accepted; Quotes are due at 1200 local on 22 September 2004. 1) Need to know if you mean 5 year Parts on whole unit or just compressor. 1 year parts on whole unit is standard (warranty period starts 18 months from shipment or 12 months from start-up - whichever occurs first) 5 YEAR PARTS ON COMPRESSOR 2) 38F is the leaving water temp. What is the entering water temp or GPM to be used to determine performance values? EVAP 440 GPM 38* LEAVEING 18 FT PRESSURE DROP./ CONDENSER 606 GPM 85 * ENTER WATER AT 11FT PRESSSURE DROP 3) No cooling tower information is provided. What is the entering condenser water temp and flow rate? THE TOWER WILL NOT BE REPLACED AT THIS TIME HOWEVER THE TOWER IS AN AIR COOLED 4) What voltage is the machine 208, 230 0r 460/3 phase?480 /3PH/60 THE OLD UNITS ARE AS FOLLOWS M/N# E20122B2RC S/N#5RF0011700 STYLE # 1FV6032G01 5.) Are the chillers for HVAC application? yes 6.) What voltage is serving the chillers (460 or 208/3/60)480/3ph/303LRA 7.) Is glycol being utilized with the system? If so, can you indicate type and percent mixture? YES, 50/50 8.) Centrifugal chiller is indicated, are other types of chillers such as screw chillers acceptable to bid? If not, can you indicate why not? THIS REQUIREMENT IS FOR A MCQUAY UNIT OR EQUAL INDICATED. IF AN OR EQUAL QUOTE IS PROVIDE, PRODUCT SPECS MUST ALSO BE SUBMITTED. 9.) R-134a refrigerant is indicated, are any other refrigerants acceptable? R-123?, R-22?, R407c? NO. 10.) Is a dimensional drawing available of the final chiller piping layout and location? NO, THE OLD UNITS ARE MCQUAY m/n E20122B2RC s/N 5RF0011700 style # 1FV6032G01 ONE IS A RIGHT HAND AND ONE IS LEFT HAND NOTE: THIS NOTICE WAS NOT POSTED TO WWW.FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (20-SEP-2004); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/USAF/ACC/55CONS/FA4600-04-T-0195/listing.html)
 
Place of Performance
Address: Offutt AFB, NE
Zip Code: 68113
Country: USA
 
Record
SN00678107-F 20040922/040921000410 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.