Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 12, 2004 FBO #1112
SOLICITATION NOTICE

C -- Indefinite Delivery-Type (Multidiscipline) Contract for Directorate of Installation Services, USAG, Fort Detrick, Frederick, MD, but may be used throughout the North Atlantic Division.

Notice Date
12/10/2004
 
Notice Type
Solicitation Notice
 
NAICS
541330 — Engineering Services
 
Contracting Office
US Army Corps of Engineers, Baltimore, 10 South Howard Street, Baltimore, MD 21203
 
ZIP Code
21203
 
Solicitation Number
W912DR-05-R-0008
 
Response Due
1/11/2005
 
Archive Date
3/12/2005
 
Small Business Set-Aside
N/A
 
Description
1. CONTRACT INFORMATION: Architect-Engineer services are required for one (1) Indefinite Delivery-Type (Multidiscipline) contract for the Directorate of Installation Services, USAG Fort Detrick, Frederick, MD but may be used throughout the North At lantic Division. The contract will be for a base period not to exceed 12 months and two option periods. An option period may be exercised when the contract amounts for the base period or preceding option period has been exhausted or nearly exhausted. Co ntract will be firm fixed priced. The total contract amount is $3,000,000.00. The anticipated award is approximately April 2005 and is open to all businesses regardless of size. SUBCONTRACTING PLAN REQUIREMENTS: If the selected firm is a large business c oncern, a subcontracting plan with the final fee proposal will be required, consistent with Section 806(b) of PL 100-180, PL 95-507, and PL 99-661. A minimum of 45% of the total planned subcontracting dollars shall be placed with small business concerns. At least 20% of total planned subcontracting dollars shall be placed with Small disadvantaged businesses (SDB), including Historically Black Colleges and Universities or Minority Institutions, 10% with Women-owned small businesses (WOSB), 3% shall be plac ed with Hubzone Small Business (HubSB), 3% with Veteran-owned small business and 3% with Service Disabled Veteran-owned small businesses. The subcontracting plan is not required with this submittal. The North American Industry Classification Code (NAICS) is 541330. For small business purposes the size standard is $4,000,000.00 average annual receipts over the last 3 fiscal years. 2. PROJECT INFORMATION: The services that may be required will consist of, but not be limited to one or more of the followin g: Design and/or Feasibility Studies for new structures, various repairs, alterations and/or improvements to Barracks, Administrative facilities, Family Housing Units, Medical Facilities, Warehouses, and other existing facilities; Building condition repor ts; Rehabilitation of historic buildings and structures; Project Management and Inspection Services for Construction projects; Auto CADD Services; Environmental Surveys, Reports, Studies, Designs for the clean-up, removal, monitoring and/or abatement of as bestos, hazardous/toxic materials and petroleum products and Lead Base paint; HVAC Replacement; ADA; Master Planning documentation and DD 1391 preparation. 3. SELECTION CRITERIA: The following are the selection criteria in descending order of importance . Criteria a - d are primary. Criteria e - f are secondary and will be used as tie-breakers among technically equal firms. (a) PROFESSIONAL QUALIFICATIONS: Certain aspects of the work are strictly related to National Security Interests, therefore it is necessary that at least the key personnel in each discipline possess valid Secret Clearances. The proposed design team(s) must also possess registered personnel with experience in the following disciplines; architecture, civil, environmental, electrical, geo-technical (soils engineer), land surveying, mechanical, and structural. In addition, the design team(s) will also require experienced personnel in the following areas: Construction Inspection, Estimating, Fire Protection, IT/Telecommunications, Plumb ing, Roofing and Specifications. A Certified Industrial Hygienist (CIH) must be part of the design team, and a copy of their Board of Industrial Hygiene Certificate MUST be included with Part I of the SF 330. Address the proposed method of carrying out th e work to meet the anticipated project requirements. (b) SPECIALIZED EXPERIENCE and TECHNICAL COMPETENCE: Address the experience of the proposed design team(s) by providing specific examples of projects in a wide variety of multi-discipline design project s and studies as listed above. Indicate work completed under current and/or recently completed Indefinite Delivery Contracts. Include Contract number(s), Poin t(s) of Contact, telephone number(s) and e-mail addresses. Firms must indicate in Part I of the SF 330 their Computer resources on the following items; (1) Accessibility to and familiarly with the Construction Criteria Base (CCB) System; (2) SPECSINTACT Specification System; (3) MASTERSPEC Master Specification Systems; (4) DRChecks Design and Review Checking System; (5) Must possess in-house/consultant AutoCADD capabilities version(s) 14 and 2002; and (6) familiarity with International Building Codes ( IBC); (7) Experience working with physical security and force protection aspects of architectural, structural, mechanical and electrical design projects. (c) CAPACITY TO ACCOMPLISH WORK. Firms must address the ability of the design team(s) to complete pr ojects within mandatory time frames, including multiple Task Orders under an IDC. Provide specific examples of such in Part I of the SF 330. A proposed management plan shall be presented that includes an organization chart indicating all key personnel to be utilized under this contract. (d) PAST PERFORMANCE. Provide examples of Past Performance on project specific work (within the past 5 years), including past and/or current IDC's, with the Department of Defense (DoD) and other Government Agencies and/o r private industry. Provide letters of evaluations and/or recognition by other clients. Provide specific examples of cost control and estimating performance on past projects under IDCs. (e) LOCATION. Location of the firm within the general geographical area of the proposed requirement as response time for certain projects may be critical. (f) VOLUME OF WORK. Provide the volume of DoD and other Government Agency contracts awarded in the past 12 months and/or currently being performed (include both the design fee and estimated construction value. 4. SUBMISSION REQUIREMENTS: Interested firms having capabilities to perform this work must submit Parts I and II of the SF 330 for the prime and joint venture(s) and Part II of the SF 330 must be submitted fo r each consultant to the address below, no later than the close of business on the 30th day after the date of this announcement. If the 30th day is a Saturday, Sunday, or Federal holiday, the deadline is the close of business the next business day. Inclu de the firms ACASS number for the prime firm, if available, on the SF 330, Part I, Block B. On the SF 330, Part I, Block C, provide the ACASS number of each consultant, (if available). If your firm does not have an ACASS number, it can be obtained from the Portland District Corps of Engineers ACASS database by calling (503) 808-4591. On the SF 330, Part I, Block F, provide title and contract award dates for all projects listed in that section. Submit responses to U.S. Army Corps of Engineers, City Cresc ent Building, ATTN: Mary A. Riche, Rm 7000, 10 South Howard Street, Baltimore, MD 21201. Technical questions should be directed to Rosario.Dimarco@DET.AMEDD.ARMY.MIL or (301) 619-2429. Contracting questions can be directed to mary.a.riche@nab02.usace.a rmy.mil or (410) 962-4880. In order to comply with the Debt Collection Improvement Act of 1996, all contractors must be registered in the Central Contractor Registration (CCR) to be considered for an award of a Federal contract. Information regarding reg istration can be obtained online at www.ccr.gov or through CCR Assistance Center (CCRAC) at 1-888-227-2423 or 269-961-4725. Effective immediately, the use of DUNS+4 numbers to identify vendors is limited to identifying different CCR records for the same v endor at the same physical location. For example, a vendor could have two records for themselves at the same physical location to identify two separate bank accounts. If you do not have a DUNS number, or want to register subsidiaries and other entities, c all Dun and Bradstreet at 1-866-705-5711. Solicitation packages are not provided. This is not a request for proposal.
 
Place of Performance
Address: US Army Corps of Engineers, Baltimore 10 South Howard Street, Baltimore MD
Zip Code: 21203
Country: US
 
Record
SN00719946-W 20041212/041210212004 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.