Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 16, 2004 FBO #1116
SOLICITATION NOTICE

59 -- Commercial Internet Connectivity Electrical Work

Notice Date
12/14/2004
 
Notice Type
Solicitation Notice
 
NAICS
238210 — Electrical Contractors
 
Contracting Office
Department of the Air Force, Air Force Space Command, 341CONS, 7015 Goddard Drive, Malmstrom AFB, MT, 59402-6863
 
ZIP Code
59402-6863
 
Solicitation Number
FA4626-05-T-0002
 
Response Due
12/27/2004
 
Archive Date
1/11/2005
 
Small Business Set-Aside
Total Small Business
 
Description
SOW FOR COMMERCIAL INTERNET CONNECTIVITY FURNISH ELECTRICAL/CABLE EQUIPMENT AND COMPONENTS FOR THE EDUCATION CENTER AT MALMSTROM AFB, MONTANA Solicitation of one total price to furnish and install all electrical/computer equipment, components, tools, accessories and materials to support a commercial internet connectivity system at the Education Center located at Malmstrom AFB, Montana with the following requirements: (a)Electrical: Furnish and install 1 225 AMP 3 phase breaker in the existing main Distribution Panel (MDP). The existing MDP is a Square D model HCWA12MNN, 120/208 Volt 3 phase, rated 480 Volts. Furnish and install new Panel c-120/208V, 3ph, 225A, 42 space distribution panel, surface mount, with copper buss, bolt in breakers, and a225 AMP breaker. Furnish and install new 2.5-inch EMT conduit with 4 #4/0 CuTHHN plus ground conductor. Feed to new panel to be run in ceiling space from the MDP in the Electrical Room to closet space, approximately 200 ft away. New panel to be surge protected with in-panel over voltage device. All electrical work to be completed by qualified licensed journeyman electrician. All electrical work to be in compliance with the 2002 National Electrical Code. (b) - Furnish and install CAT5e plenum rated cable hung with D-rings for desk jacks in rooms 101, 102 and 103. (All cabling will be tested and certified). c) - Room 101; furnish and install 45-computer port drops hardwired to desks. Length of CAT5e for all drops should not exceed 9000 Ft. All Drops should be terminated using the TIA Standard 568B. d) - Room 102; furnish and install 45-computer port drops hardwired to desks. Length of CAT5e for all drops should not exceed 9000 Ft. All Drops should be terminated using the TIA Standard 568B. e) - Room 103; furnish and install 41-computer port drops hardwired to desks. Length of CAT5e for all drops should not exceed 8200 Ft. All Drops should be terminated using the IA Standard 568B. f) - Rooms 101, 102, and 103 (Electrical) -Furnish and install 6 each 20 amp single pole breakers per room in Panel C (18 total). -Furnish and install 6 each 20 AMP circuits (2#12CU THHN w/gnd) per room from Panel C to rooms (18 total circuits). Do not use shared neutrals. Circuits to be run in /EMT conduit in ceiling space and flexible metal conduit in wall space. Distance between Panel C and each room is approximately 100 ft. -Furnish and install 22 duplex receptacles in each room (4 duplex receptacles). Receptacles will be evenly spaced around the step riser of a two tier riser floor. Distance encircling step one is approximately 60 ft. There shall be 10 receptacles encircling step one and 12 receptacles encircling step two. Receptacles shall be surface mounted in 4000 Series Wiremold (Ivory Colored) or equal as approved by the Contracting Officer. Wiremold shall have a divided space for communication cables, and integral communication jacks at each electrical receptacle. These are two runs of Wiremold of approximately 60 ft long (120 ft total) in each room. The Wiremold will have two 90 degree angles in each run to complete a horseshoe shaped loop. The loop shall terminate at the wall on each end of the loop, and the new in-wall circuits shall feed the Wiremold. g) - Room 104; furnish and install 1 four port and 1 single port computer port (5 ports). Run wire to 4 existing four-port computer ports. Length of CAT5e for all drops should not exceed 2000 Ft. All Drops should be terminated using the TIA Standard 568B. h) - Rooms 105, 106 and 107; furnish and install 1 single jack in each room (3 jacks). (Includes cabling back to new rack) Length of CAT5e for all drops should not exceed 600 Ft. All Drops should be terminated using the TIA Standard 568B. i) - Room 108; furnish and install 5 four-port computer ports -Room 108 Electrical --Furnish and install 4 20 AMP single pole breakers in Panel C. --Furnish and install 4 circuits (2 # 12 cu THHN w/gnd in EMT conduit) from Panel C to room 108 (approximately 150 ft). Do not use shared neutrals. Circuits may be routed within walls using flexible metal conduit. --Furnish and install 4 20 AMP duplex receptacles spaced evenly around room 108, each on a dedicated 20 AMP circuit. j) - Room 115; furnish 1 six foot standing rack, 2- 96 port patch panels or 4- 48 port patch panels and testing of cables. Room 115: Furnish and install 1ea 7ft, standing 19inch open frame rack (Hubbell Aluminum 84 inch HPW84RR19ML or equivalent), 2-96 port patch panels or 4-48 port patch panels. Termination of CAT5e will be TIA Standard 568B. All drops will be tested IAW TIA/EIC Standards for TIA 568B. - Room 115 Electrical Furnish and install 1 20 Amp receptacle on dedicated 20 AMP circuit (2 #12 cu THHN, w/gnd) from Panel C, approximately 120 ft. k) Site Visit on 21 Dec 2004 at 1000, please call Deb Lacy at 406-731-4007 for additional details. l) Delivery requested no later than 31 Jan 2005. FOB destination, 341 MSS/DPHS, 4th Ave N., Bldg. 1240 Malmstrom AFB, MT 59402-6865.SB -7507
 
Place of Performance
Address: 4th Ave N Bldg 1240, Malmstrom AFB, Montana
Zip Code: 59402
Country: USA
 
Record
SN00721099-W 20041216/041214212049 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.