Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 16, 2004 FBO #1116
SOLICITATION NOTICE

41 -- Turn key removal, replacement/refurbishment and startup of the air conditioning unit through exsisting air handler SEE DESCRIPTION BELOW

Notice Date
9/7/2004
 
Notice Type
Solicitation Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Air Force, Air Mobility Command, 6th Contracting Squadron, 2606 Brown Pelican Ave., MacDill AFB, FL, 33621-5000
 
ZIP Code
33621-5000
 
Solicitation Number
F1360342180100
 
Response Due
9/27/2004
 
Point of Contact
Charles Hoyle, Contract Specialist, Phone 813-828-7467, Fax 813-828-3667, - Stephen Karpacs, NCOIC, Base Support Flight, Phone 813-828-7465, Fax 813-828-3667,
 
E-Mail Address
charles.hoyle@macdill.af.mil, stephen.karpacs@macdill.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is F1360342180100, Request for Quotation. The solicitation incorporates provisions and clauses as those in effect through Federal Acquisition Circular 97-26. The North American Industry Classification System Code (NAICS) is 238220 Plumbing, Heating and Air-Conditioning Contractor the size standard of which is $25.7M per year. This procurement is set-aside for small business in accordance with the Small Business Competitiveness Demonstration Program. LOCATION: Avon Park Air Force Range, Bldg 77, Florida, 33825 DESCRIPTION: Remove existing condenser, water piping, chiller compressor, exiting air handler water coils, and pneumatic controls · Install two new Dx coils and all piping in existing air handler or replace air handler if not compatible with proposed equipment. Contractor shall supply all controls, txv’s, filters, and sight glasses · Install one new Trane model # CRAUC80-1 or equivalent condensing unit. Contractor shall supply all piping and control wiring · Install one new nonadjustable temperature sensor in hallway. Also, include a supply air-temperature sensor, a discharge temperature sensor, and one adjustable transmitter · Install freeze-protection controls on unit · Install isolation valves on all filter cores · Separate line item for High Voltage hookup · Provide refrigerant piping or specialties, thermostats, controls or control interlock wiring, vibration isolators, disconnects, and smoke detectors/firestats · Start-up system · One complete set of replacement belts · Provide 1-year labor warranty Tag Data - Cooling Coils (Qty: 2) Item Tag(s) Qty Description Model Number A1 CLCL-1 1 Cooling coil DF B24108--EC117BABA0-ABBA00 A2 CLCL-1 1 Cooling coil D B30108--EC117BABA0-ABBA00 Product Data - Cooling Coils All Units F coil 5/8" DX Packed elbows Cooling unit with drain holes Shipping coil Right hand supply Galvanized steel casing (Std) 6 rows 108" (2743 mm) finned length Aluminum fins Prima-flo E (energy efficient) 117 fins per foot .020 (0.508 mm) std copper tubes Pegasus coil ARI ranges applied ARI rated and certified Horizontal split 1/4" (6mm) Diameter Distributor Tubes Full Circuiting Item: A1 Qty: 1 Tag(s): CLCL-1 24" (610 mm) coil height Item: A2 Qty: 1 Tag(s): CLCL-1 30" (762 mm) coil height Tag Data - Air-Cooled Condensing Units (Industrial)) (Qty: 1) Item Tag(s) Qty Description Model Number B1 RAUC80-1 1 80-120 Ton Air-Cooled Condensing Unit ( RAUCC804B Product Data - Air-Cooled Condensing Units (Industrial)) Item: B1 Qty: 1 Tag(s): RAUC80-1 80 Ton Unit 460 Volt 60 Hertz 3 Phase No System Control Standard Ambient Control UL / CSA Approval Suction service valves Unit Spring Isolators (Fld) 2nd-5th Year Replacement Compressor Warranty PROVISIONS/CLAUSES: The following FAR and DFARS provisions and clauses (http://farsite.hill.af.mil) apply: 52.212-1, Instruction to Offerors—Commercial. In accordance with 52.212-2, Evaluation—Commercial Items, offers will be evaluated based on price, technical acceptability, delivery schedule, adherence to applicable clauses and provisions, as well as past performance records. Offerors are to submit with their offers, a completed copy of 52.212-3, Offeror Representations and Certifications—Commercial Items. 52.212-4, 52.212-5, 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.222-19, 52.225-13, 52.232-33, 252.212-7001, 252.225-7001, 252.247-7024. For the exact text and wording DEADLINE: Offers are due on 27 August 2004, by 2:00PM EST. Submit offers to the attention of TSgt Charles W.Hoyle Jr (Tel 813-828-7467), 6CONS/LGCA, via fax 813-828-3667 or via email charles.hoyle@macdill.af.mil Questions about specifications will be address via email to the aforementioned. Site visits are recommended Subject item due to the availabilty of funds. No oligation may be incurred until fund avaiability has been certified. NOTE: THIS NOTICE MAY HAVE POSTED ON WWW.FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (07-SEP-2004). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 14-DEC-2004, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/USAF/AMC/6CS/F1360342180100/listing.html)
 
Place of Performance
Address: Avon Park Air Force Range
Zip Code: 33825
 
Record
SN00721658-F 20041216/041214213554 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |