Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 23, 2004 FBO #1123
MODIFICATION

Y -- Southern Maine, ME P&DC 512582-05-A-0001

Notice Date
12/21/2004
 
Notice Type
Modification
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
United States Postal Service, Facilities Purchasing, Major Facilities Purchasing (HQ), 4301 Wilson Blvd Ste 300, Arlington, VA, 22203-1840
 
ZIP Code
22203-1840
 
Solicitation Number
512582-05-A-0001
 
Response Due
1/5/2005
 
Archive Date
1/20/2005
 
Point of Contact
Bill Powell, Purchasing Specialist, Phone (703) 526-2764, Fax (703) 526-2747, - Tim Bonsall, Purchasing Specialist, Phone (703) 526-2770, Fax (703) 526-2747,
 
E-Mail Address
bpowell1@email.usps.gov, tbonsall@email.usps.gov
 
Description
USPS SOUTHERN MAINE P & DC SOLICITATION DOCUMENTS - AMENDMENT 3 Issued ? December 21, 2004 Minutes from pre-proposal Meeting (for reference only ? not part of contract) ISP allowance and procedures: Include $16,800 for ISP fee And $14,000 for ISP rack system as described in ISP.pdf Attachment 01 ? Replace existing Table of Contents with attached Section Table of Contents-12-19-04.pdf Replace existing Section 07251-Fireproofing1 with attached Section 07251-Fireproofing12-19-04.pdf Insert Section 07820-Unit Skylights12-19-04.pdf Replace existing Section 08361-Knockout doors1 with attached Section 08361-Knockout doors12-19-04.pdf Replace existing Section 09900-Painting1 with attached Section 09900-Painting12-19-04.pdf Replace existing Section 10350-Flagpoles1 with attached Section 10350-Flagpoles12-19-04.pdf Insert Section 10655-Accordian Folding Partitions12-19-04.pdf Replace existing Section 11160-Loading dock equipment1 with attached Section 11160-loading dock equipment12-19-04.pdf Insert Section 11190-truck scales12-19-04.pdf Insert Section 11400-food service equipment12-19-04.pdf Attachment 15 ? Replace existing List of pre-qualified contractors prequalcontractors.pdf Attachment 16 ? Functional Design Specifications ? Section 2 Storm Water Management System: Include complete review and inspections of proposed building with Scarborough Fire Department. Contractor is responsible for payment of review and inspection fees. Functional Design Specifications ? Section 4 Special Construction: Provide one ceiling hung Accordian Folding Partition in the Multi-Purpose Room. This partition will divide the room in two equal sections. Partition may be two-part, collapsing to either side. The following DRAWINGS have been revised ? All changes are marked. C1.04 GRADING DRAINAGE PLAN replace existing drawing with attached drawing. Missing files that were not uploaded to the Skire on Amendment 1: ME-1 MECHANIZATION SCHEDULES, DRAWING INDEX & NOTES BULK MAIL SYSTEM ME-2 MECHANIZATION SCHEDULE TRAY MAIL SYSTEM ME-4 COMPOSITE PLAN VIEW MECHANIZATION ME-12 CONVEYOR ELEVATIONS TRAY MAIL SYSTEM ME-19 MECHANIZATION DETAILS, TRAY MAIL SYSTEM ME-23 MONITOR MASK, BULK MAIL SYSTEM
 
Place of Performance
Address: Southern Maine, ME, Scarborough
 
Record
SN00724791-W 20041223/041221212405 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.