SOLICITATION NOTICE
41 -- TEMPERATURE-HUMIDITY-ALTITUDE CHAMBER
- Notice Date
- 1/25/2005
- Notice Type
- Solicitation Notice
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- ACA, White Sands Missile Range, Directorate of Contracting, Bldg 143, 2nd Floor, Crozier Street, White Sands Missile Range, NM 88002-5201
- ZIP Code
- 88002-5201
- Solicitation Number
- W9124Q-CHAMBER
- Response Due
- 1/31/2005
- Archive Date
- 4/1/2005
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotation s are being requested and a written solicitation will not be issued. This requirement is set-aside 100% for small business. The applicable NAICS code is 333415 with a size standard of 500 employees. Your price shall be FOB Destination. We have a requirement for a Temperature/Humidity/Altitude Chamber, which shall meet the following minimum requirements: The chamber shall have a temperature range of minus 51 degrees C Centigrade - to plus 71 degrees C. Altitude range from site level to plus 200,000 feet. Minimum chamber internal dimensions of 24 inch x 24 inch x 24 inch. Chamber shall have a sealable access port at least 3 inches in diameter, with Aluminum Cover, or equivalent. Chamber shall have a viewing window. Temperature rate of change shall be at least 1 degree C per minute Altitude rate of change shall be at least 4000 feet per minute up to 150,000 feet. Relative Humidity shall be controllable from 20% to 95% at temperatures ranging from 10 degrees 60 degrees C Temperature, humidity, and altitude shall be controlled with a programmable controller (Watlow F4 and Watlow SD controllers with RS-485 outputs or equivalent). Safety shutoffs shall be provided when over/ under temperature limits are exceeded. Chamber shall operate in the combine environment of steady state or cycling temperature up to 60,000 feet in altitude. Chamber shall operate in the combined environment of steady state or cycling temperature and humidity at site level altitudes. Chamber shall be fabricated with corrosion resistant materials. Refrigerants shall be non-ozone depleting. The chamber shall have a run time meter to log chamber running time. The chamber shall be provided with a main power disconnect switch. The chamber shall be provided with an adjustable stainless steel shelf. The chamber shall be provided with low and high refrigeration pressure gauges or equivalent. The chamber shall come with at least 4 extra water demineralization cartridges. Two copies of chamber drawings, schematics, and operating manuals shall be provided. Inspection and acceptance shall be performed at destination. We prefer to make payment by VISA credit card. You must be registered in the Central Contractor Registration http://www.ccr.gov. If you are not in the CCR at the time we are ready to make the award, you will be disqualified. The following Federal Acquisition Regulation (FAR) provisions and clauses are applicable to this solicitation: FAR 52.212-1, FAR 52.212-3, FAR 52.212-4, FAR 52.212-5, FAR 52.219-21, FAR 52.222-35, FAR 52.222-36, FAR 52.2 32-33, FAR 52.232-36, DFARS 252.225-7001. The full text of these clauses may be found at http://www.farsite.hill.af.mil or http://www.arnet.gov/far. Your quotation shall be submitted by email to jojolaja@wsmr.army.mil no later than Noon, 12:00 PM MST, 31 January 2005.
- Place of Performance
- Address: ACA, White Sands Missile Range Directorate of Contracting, Bldg 143, 2nd Floor, Crozier Street White Sands Missile Range NM
- Zip Code: 88002-5201
- Country: US
- Zip Code: 88002-5201
- Record
- SN00739675-W 20050127/050125212019 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |