SOLICITATION NOTICE

J -- GE breaker repairs

Notice Date
2/18/2005
 
Notice Type
Solicitation Notice
 
NAICS
238210 — Electrical Contractors
 
Contracting Office
US Army Engineer District, New Orleans, ATTN: CEMVN-CT, P.O. Box 60267, New Orleans, LA 70160-0267
 
ZIP Code
70160-0267
 
Solicitation Number
W912P8-05-Q-0008
 
Response Due
2/28/2005
 
Archive Date
4/29/2005
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is W912EQ-05-Q-0008 and is being issued as a Request for Quote (RFQ). This solicitation incorporates Wage Determination No. 94-2495 REV (27). This is an UNRESTRI CTED procurement. The associated NAICS code is 238210 with $12 M. All responsible sources may submit a quotation, which shall be considered by the agency. Quotes may be submitted in hard copy or electronically, either through regular mail, email, or by facsimile. Regardless of method of delivery, it is the offerers responsibility to ensure receipt of quotes by the time and date stated herein. Contractors shall submit a lump sum quotation to include all charges. WORK SCOPE FOR DREDGE HURLY BREAKER REPAIRS 1. Open, inspect, clean and lubricate all GE type AKR circuit breakers, approximately 15 breakers. 2. Correct cubicle binding problems with generator #2 cubicle. The current breaker must be crow bared into position. 3. Replace all cubicle safety interlock cam followers missing on each generator breaker. 4. Replace broken racking gear on generator #1 breaker. 5. Replace missing safety manual close interlock mechanism intended to prevent manual closing of a generator breaker when fully engaged into the cubicle. 6. Eliminate one turn shorted transformer action in cubicle, Original design of the cubicles created a one turn shorted transformer by placing one phase on one side of a conductive brace with the other two phases on the other side of the brace. Cubicles s teel become hot during operation by this arrangement and steel will buzz loudly. 7. Confirm that required ventilation opening in back of the generator breakers have been cut open. As found no opening is present, opening is required by GE breaker design. Original manufacturer error. 8. Replace all primary disconnects on the back of generator #3 breaker. As found during inspection this cubicle showed advanced evidence of being ready to flash over due to heat build up. 9. Replace generator #2 temperature meter cover that has become clouded such that the meter is no longer readable. Meter is YEW type AB 40. 10. Adjust all secondary disconnects to be close to center of cubicle connection block tracks. Will require adjustment of both breaker side and cubicle side disconnect assemblies. 11. Correct wheel issues with generator #1 cubicle. Mounting plate bolts damaged and loose. 12. Supply a spare Z drive breaker OEM style AKR50 with secondary disconnect and aux switch. 13. Supply a spare main generator circuit breaker AKR 100 OEM style with all required features. 14. Research need for generator cubicle position switches on main generators. As found cubicle position switches are present but not being used. 15. Remove UV tripping from propulsion drive circuit breakers and transform primary circuit breakers as directed by ship engineers. All UV devices are presently tied up to prevent UV trips on loss of plant. Contractor shall submit completed clause 52.212-3, Offerors Representation and Certifications, Commercial Items. The following clauses and provisions are incorporated and will remain in full force in any resultant award. The full text of these clauses ca n be accessed electronically at website: http://www.farsite.hill.af.mil. FAR 52.212-1 - Instructions to Offerors--Commercial Items is applicable to this solicitation. The provisions at FAR 52.212-2 - Evaluation of technical capability and price with tech nical capability being greater in importance than price. FAR 52.212-3, Offeror Representation and Certifications--Commercial Items. FAR 52.212-4 - Contract Terms and Conditions--Commercial Items. FAR 52.212-5 Contract Terms a nd Conditions Required to Implement Statues or Executive Orders--Commercial Items (Dev); FAR 52.222-3 Convict Labor; FAR 52.222-19 Child Labor; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-35 Equal Opportu nity of Special Disabled Veterans, Dec 2001 Veterans of the Vietnam Era and Other Eligible Veterans; 52.222-36 Affirmative Action for Workers with Disabilities; FAR 52.222-37 Employment Reports on Disabled Veterans; FAR 52.225-13 Restrictions on Certain Fo reign Purchases; FAR 52.232-33 Payment by Electronic Funds Transfer--Central Contractor Registration; 52.222-41 Service Contract Act of 1065; FAR 52.222-42 Statement of Equivalent Rates for Federal Hires; FAR 52.252-2 Clauses Incorporated by Reference; 52. 237-1 Site Visit; DFARS 252.212-7001 Contract Terms and Conditions Required to Implement Statues or Executive Orders applicable to Defense Acquisitions of Commercial Items--FAR 252.232-7003 Electronic Submission of Payment Requests; FAR 252.247-7023 Transp ortation of Supplies by Sea, Alternate III. Response to this combined synopsis/solicitation must be received via email, fax, mail, or delivery by 28 February 2005 no later than 4:00 PM local time at 167 North Main Street B202, Memphis, TN 38103. Quotes should be marked with solicitation number W912 EQ-05-Q-0008 addressed to Celestine Evans, Contract Specialist, Phone (901) 544-3184, Fax (901) 544-3710, email: celestine.g.evans@mvm02.usace.army.mil. Vendors not registered in Central Contractor Registration (CCR) database prior to award will not be el igible for award. Vendors may register for CCR by calling 1-800-334-3414 or register online at www.ccr.gov.
 
Place of Performance
Address: US Army Engineer District, New Orleans ATTN: CEMVN-CT, P.O. Box 60267 New Orleans LA
Zip Code: 70160-0267
Country: US
 
Record
SN00755049-W 20050220/050218213030 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.