MODIFICATION
60 -- Local Area Network of the Iraqi Republic Railway
- Notice Date
- 11/7/2004
- Notice Type
- Modification
- NAICS
- 238210
— Electrical Contractors
- Contracting Office
- Department of the Army, Project and Contracting Office, Project and Contracting Office, Iraq, Republican Presidential Compound APO, Baghdad, Iraq, AE, 09316
- ZIP Code
- 09316
- Solicitation Number
- W914NS-05-Q-0003
- Response Due
- 11/22/2004
- Point of Contact
- Charles Clements, Support Contractor, Phone 703-343-9218, Fax 703-343-9227,
- E-Mail Address
-
charles.clements@cpa-iq.org
- Description
- This is a modification to the combined synopsis / solicitation W914NS-05-Q-0003 for a local area network to be installed at the Iraqi Republic Railway (IRR) headquarters and two other nearby IRR sites. The purpose of this modification is to restructure the Contract Line Item Number (CLIN) structure, provide answerers to questions posed by Industry in the last several weeks and to extend the due date of the quote. THE CLINS 1. CLIN 0002 is deleted. 2. CLIN 0005 is added. 113 each desktop computers Compaq dc5000 Business Minitower with Norcent 17 inch LCD monitor and Arabic keyboards or equal loaded with the Arabic version of the following software or equal: MS-Office, Adobe Acrobat, Clarisys Executive, or FoxPro, AK Microsystems’ PayMate, InterTicket, Circadian FRCOS, MS-Project, Mincom Ellipse, and Venice Systems. Computers to be configured for the 220V, 3-phase 50 Hz Iraqi electrical system. 3. CLIN 0006 is added. 37 each desktop computers Compaq dc5000 Business Minitower with Norcent 17 inch LCD monitor and English keyboards or equal loaded with the English version of the following software or equal: MS-Office, Adobe Acrobat, Clarisys Executive, or FoxPro, AK Microsystems’ PayMate, InterTicket, Circadian FRCOS, MS-Project, Mincom Ellipse, and Venice Systems. Computers to be configured for the 220V, 3-phase 50 Hz Iraqi electrical system. 4. CLIN 0007 is added. 5 each Hewlett Packer 8250 or equal document scanners. Scanners to be configured for the 220V, 3-phase 50 Hz Iraqi electrical system. 5. CLIN 0008 is added 5 each Belkin or equal 600 watt Uninterrupted Power Supply (UPS) units, 3-hour supply of power. UPS units to be configured for the 220V, 3-phase 50 Hz Iraqi electrical system. 6. CLIN 0008 5 each Hewlett Packer 4560 or equal color laser printers. Printers to be configured for the 220V, 3-phase 50 Hz Iraqi electrical system. 7. CLIN 0009 10 sets of replacement cartridges for CLIN 0008 color printer 8. CLIN 0010 30 each license for AutoCAD 2004, in English. QUESTIONS AND ANSWERS 1. Can you confirm that we can bid for a completely wireless network (except for the computer room where servers will be wired)? Yes, you may bid for a completely wireless network. The IRR prefers a wireless system but realizes the limitation with potential dead spaces in the building. A combination of wire and wireless networks is also acceptable. The Contractor shall propose the best LAN architecture as part of the solicitation. 2. In the meeting we were informed that in addition to the 50 laptops stated in the solicitation, the department is expecting a quote for 150 desktops. Is this correct and should we offer that? The solicitation mentions 50 laptops. After further consideration, the IRR would prefer to include 150 desktop computers with the solicitation. Assume Compaq, or equivalent high-end computers. New desktops are needed because many of the existing computers are out-dated, low quality, and will not be compatible with the network design. In addition, the contractor will provide 5 document scanners and 5 color laser printers. Assume high-end brand equipment for budgeting purposes. 3. In the meeting there was referenced to three other locations than the main building, while in the solicitation it was stated two locations only other than the main building. Also, in the meeting it was stated that the distance to these locations is about 3Km while in the solicitation it is stated as 1.3Km. Can you please clarify the correct number of locations and distances involved? There are two locations in addition to the main station building requiring connectivity to the LAN. Distribute the 150 desktop network computers in all three locations ( Baghdad Station - Technical Station Building -Shalchiya ) 1. Shalchiya Shops, approximately 5 Km from the main station;. 2. Between the main station and Shalchiya Shops is the Technical Station Building, a NOTE: THIS NOTICE MAY HAVE POSTED ON WWW.FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (07-NOV-2004). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 10-MAR-2005, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.eps.gov/spg/USA/CPAIRAQ/APOAE/W914NS-05-Q-0003/listing.html)
- Place of Performance
- Address: BAGHDAD
- Country: IRAQ
- Country: IRAQ
- Record
- SN00766466-F 20050312/050310213642 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |