SOURCES SOUGHT
99 -- Design and Fabricate Connector Plate Test Fixture
- Notice Date
- 3/29/2005
- Notice Type
- Sources Sought
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- Department of Energy, Bechtel Nevada Corp (DOE Contractor), Bechtel Nevada, PO Box 98521, Las Vegas, NV, 89193
- ZIP Code
- 89193
- Solicitation Number
- Reference-Number-03-TW-05
- Response Due
- 4/12/2005
- Archive Date
- 4/27/2005
- Description
- Bechtel Nevada is seeking sources capable of furnishing all labor, material, and services required for providing two PTC Connector Plate Test Fixtures. The test fixtures will be used to pressure test and vacuum leak check PTC connector plates. The purpose of this sources sought notification is to ascertain capable sources for producing the test fixtures. Preliminary information includes: 1. Fixtures to be ASME Section VIII vessels. 2. Fixtures will be used to pressure and vacuum leak test PTC connector plates. 3. Working pressure for the fixtures is 250 psig. 4. Source will be asked to design, fabricate, test, and deliver the fixtures in accordance with a purchase order and specification. 5. Source will have a QA Program meeting the requirements of 10CFR830.120. 6. Source will develop a test program to pressure test the fixtures to either 1.5 times the maximum allowable working pressure (hydrotest) or 1.25 times the maximum allowable working pressure (pneumatic test). 7. Source will develop a test program to ensure the fixtures can be used to vacuum/helium leak check the PTC connector plates. PTC connector plates to be vacuum tested with the fixtures per ASTM E 498-95 Method A, with maximum allowable leak rate of 1 x 10-5 ATM CC/SEC Helium with all volume to residual gas analysis or mass spectrometer leak detector. 8. Documentation requirements will include submittals on QA program, calculations, drawings, welder certs and quals, test results, CMTRs, ASME certification paperwork, inspection results, etc. 9. Include time for hold point inspections (weld, finish, others?). 10. Reference the attached sketch. (Notify buyer with email address to receive copy of sketch) 11. Fixtures to be of steel construction. Mating flange to connector plate will be machined to mate with the connector plate and provide a sealing surface to meet pressure test and vacuum leak check requirements. Interested sources should furnish the Point of Contact below the following information: 1. Outline of companies Quality Assurance Program to show compliance with 10CFR 830.120. 2. Letter of Interest which includes brief outline of your company?s capabilities.
- Place of Performance
- Address: Nevada Test Site, Mercury, NV
- Zip Code: 89032
- Zip Code: 89032
- Record
- SN00777623-W 20050331/050329211804 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |