Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 13, 2005 FBO #1264
SOLICITATION NOTICE

Z -- Paint Healthcare Suite COE

Notice Date
5/11/2005
 
Notice Type
Solicitation Notice
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Savannah Property Management Center, 124 Barnard St., Room B-114, Savannah, GA, 31401
 
ZIP Code
31401
 
Solicitation Number
GS-04P-05-RTM-0052
 
Response Due
6/1/2005
 
Archive Date
6/16/2005
 
Point of Contact
Marilyn Clark, Contracting Officer, Phone 912-652-4327, Fax 912-652-4559, - Marilyn Clark, Contracting Officer, Phone 912-652-4327, Fax 912-652-4559,
 
E-Mail Address
marilyn.clark@gsa.gov, marilyn.clark@gsa.gov
 
Small Business Set-Aside
8a Competitive
 
Description
The contractor shall furnish all supplies, material, equipment, labor and supervision to perform interior work in the Healthcare Suite located on the first floor of the J.G. Low Federal Building, 100 W. Oglethorpe Avenue, Savannah, Georgia. MAGNITUDE OF CONSTRUCTION IS UNDER $10,000.00. A PRE-BID SITE VISIT WILL TAKE PLACE ON 17 MARCH 2005 AT 9:00 AM EST. A SOLICITATION PACKAGE WILL BE HANDED TO ALL POTENTIAL OFFERORS AT THAT TIME. PROJECT SUMMARY: This work includes interior repainting of walls through-out the suite. It also includes refinishing all interior doors w/frames and replacing ceiling tile in the entrance to the suite. The Suite location is shown on the attached drawing excerpt of the First Floor. SCOPE OF WORK: The contractor shall provide all labor, material, equipment and supervision as required to complete the following work: 1. Move, cover and properly protect furniture and contents as needed to access all walls for painting. 2. Prep and paint approximately 4,100 square feet of gypsum wall board with two coats of Latex paint, to match existing colors. All walls will be painted except the storage closet in the main corridor and supply storage area (Room #4), located at the southwest side of the suite. 3. Prep and refinish all flush interior doors (Stained Fin.) with one coat varnish. 4. Prep and paint all metal door frames and trim with two coats of Latex semi-gloss paint, to match existing colors. 5. Remove and replace approximately 200 square feet of fissured mineral fiber lay-in ceiling tile in Room #1. In this room all ceiling tile will be replaced but the existing ceiling grid will remain. 6. Remove and replace other damaged ceiling tile through-out the suite with undamaged ceiling salvaged from Room #1. 7. Move all furniture and contents to the original locations after work is completed. SPECIAL STIPULATIONS: 1. All work shall be scheduled and coordinated with the occupants to minimize disruption of normal work in the area. 2. Work hours shall be restricted to allow for proper drying of painted surfaces and to ventilate the area prior to normal business operations. Work shall commence no earlier than 6:00 P.M. on Fridays and be completed no later than midnight on Saturdays. PERFORMANCE PERIOD: 30 Calendar days from receipt of Notice to Proceed. ALL POTENTIAL CONTRACTOR SHALL COMPLY WITH FAR 52.212-3, OFFEROR REPRESENTATIONS AND CERTIFICATIONS - COMMERCIAL ITEMS ALL POTENTIAL CONTRACTORS SHALL BE REGISTERED ON LINE WITH THE CENTRAL CONTRACTOR REGISTRY. WAGE DETERMINATION GENERAL DECISION NO GA030004 AS SEEN BELOW SHALL BE INCORPORATED INTO THE SOLICITATION. General Decision Number: GA030004 02/11/2005 GA4 Superseded General Decision Number: GA020004 State: Georgia Construction Type: Building County: Chatham County in Georgia. BUILDING CONSTRUCTION PROJECTS (does not include residential construction consisting of single family homes and apartments up to and including 4 stories) Modification Number Publication Date 0 06/13/2003 1 02/13/2004 2 07/09/2004 3 02/11/2005 BOIL0026-001 01/01/2004 Rates Fringes Boilermaker....................$ 25.18 12.67 ---------------------------------------------------------------- * ELEC0508-001 09/01/2004 Rates Fringes Electricians: Instrumentation Technician..$ 20.70 6.38 Journeyman Wireman..........$ 19.00 6.31 Nuclear Work................$ 22.75 6.46 ---------------------------------------------------------------- * IRON0709-001 07/01/2004 Rates Fringes Ironworker, reinforcing and structural.....................$ 18.30 6.37 ---------------------------------------------------------------- SUGA1988-001 03/01/1988 Rates Fringes Asphalt Raker..................$ 6.75 Bricklayer.....................$ 11.00 Carpenter (excluding drywall hanger & insulator)............$ 10.04 Cement Mason...................$ 9.95 Laborer........................$ 5.53 Mason Tender...................$ 5.50 Painter (excluding drywall finisher)......................$ 9.54 Pipefitter.....................$ 12.78 Plasterer......................$ 9.00 Plumber........................$ 11.09 Roofer (including Built Up, Composition and Single Ply)....$ 7.03 Sheet Metal Worker.............$ 8.29 Truck Driver...................$ 6.75 ---------------------------------------------------------------- WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental. ================================================================ Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)). ---------------------------------------------------------------- In the listing above, the "SU" designation means that rates listed under the identifier do not reflect collectively bargained wage and fringe benefit rates. Other designations indicate unions whose rates have been determined to be prevailing. ---------------------------------------------------------------- WAGE DETERMINATION APPEALS PROCESS 1.) Has there been an initial decision in the matter? This can be: * an existing published wage determination * a survey underlying a wage determination * a Wage and Hour Division letter setting forth a position on a wage determination matter * a conformance (additional classification and rate) ruling On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.) and 3.) should be followed. With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to: Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to: Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue. 3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to: Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W. Washington, DC 20210 4.) All decisions by the Administrative Review Board are final. ================================================================ END OF GENERAL DECISION
 
Place of Performance
Address: U.S. Army Corps of Engineers, 100 West Oglethorpe Ave, Savannah, GA
Zip Code: 31410
Country: USA
 
Record
SN00805152-W 20050513/050511212756 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |