Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 19, 2005 FBO #1270
MODIFICATION

43 -- PUMPS, vertical turbine

Notice Date
5/17/2005
 
Notice Type
Modification
 
NAICS
333911 — Pump and Pumping Equipment Manufacturing
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC Pearl Harbor, Bldg. 475-2, Code 200 1942 Gaffney Street, Suite 100, Pearl Harbor, HI, 96860-4549
 
ZIP Code
96860-4549
 
Solicitation Number
N0060405TB035
 
Response Due
5/19/2005
 
Archive Date
6/3/2005
 
Point of Contact
Deborah Alberto, Contracting Officer, Phone 808-473-7539, Fax 808-473-5750, - Deborah Alberto, Contracting Officer, Phone 808-473-7539, Fax 808-473-5750,
 
E-Mail Address
deborah.alberto@navy.mil, deborah.alberto@navy.mil
 
Small Business Set-Aside
Total Small Business
 
Description
The purpose of this amendment is to answer questions received in response to the solicitation. 1. Q: Do you want just the bowl? A: Replacement pump end assembly is required. All that is required is a replacement pump end assembly to fit to our existing columns, discharge head, line shafts and motor assy. 2. In order to supply the entire pump, what is the: Q: Length or depth of pit of pump: A: Not applicable, not procuring a complete pump package Q: Size of discharge A: Not applicable, we are not procuring the discharge head Q: Horse power of motor on pump A: Not applicable, not procuring motor Q: Material of construction for discharge head A: Not applicable not procuring discharge Q: HEAD, for column A: Not applicable not procuring columns Q: Line shafting A: Not applicable not procuring the line shafting. 3. Q: What is the size of pump and motor so we can supply the right replacement? Pump Info: Size of pump: 8" x 16 1/2" Disc Head: 12 x 12 x 20 Line Shaft size: 1 1/2 " Line Shaft: 1 15/16" Product Lubed, Product Lubed Type: 12 LKM Type: 16 HXBF Stage: 6 Stage : 4 GPM: 800 GPM: 2500 Impeller: Enclosed Impeller: Enclosed Strainer: Yes Sytrainer: Yes Motor Info: Type: VHS Type: HSRG HP: 100 RPM: 1770 HP: 350 RPM 1800 PH: 3 HZ: 60 PH: 3 HZ: 60 Volts: 460 Volts: 460 Frame #: 360TP Frame #: 505UP Type Coupling: Threaded Type Coupling: Threaded 800 GTM TDH 386 feet DTH 12B90A ? 6 stage Vertical Turbine Pump Drawing No. R001167 The date and time for receipt of intial offers remains 2 p.m. Hawaii Standard Time (HST) on 18 May 2005.
 
Record
SN00809763-W 20050519/050517212629 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.