SOLICITATION NOTICE
49 -- K RACK MATERIAL/SUPPLIES/LABOR
- Notice Date
- 6/13/2005
- Notice Type
- Solicitation Notice
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Kings Bay Det, 930 USS Hundley, Bldg 2012 Naval Submarine Base, Kings Bay, GA, 31547
- ZIP Code
- 31547
- Solicitation Number
- Reference-Number-N444665122V650
- Response Due
- 6/27/2005
- Archive Date
- 7/12/2005
- Small Business Set-Aside
- Total Small Business
- Description
- STATEMENT OF WORK FOR BLDG 600 K?RACK REPAIRS Procurement, Replacement and Repair pallet rack uprights and horizontal beam supports. Includes the procurement and installation of a crash guard safety rail system at the end of each pallet rack row at Trident Refit Facility, Code 500 SWSSW Warehouse Bldg 6003. Remove, Procure new and replace sixty (60) damaged Teardrop style, heavy-duty pallet rack uprights, measuring 17 feet high by 36 inches deep with 3 inch by 3-inch post. The removal of each bay of uprights will require the removal and re-installation of five (5) 108 inches long by five (5) inch wide beams. Eight (8) teardrop style beams are currently welded to damage uprights and will require procurement of new beams and replacement. Remove, procure new and replace two (2) damaged Keystone Style uprights measuring Sixteen (16) feet high by forty-two (42) inches deep with three (3) inches by 1 5/8 inch post. Remove ten (10) damage sections from Frick Gallagher pallet rack upright support and weld in replacement sections of channel steel. Procure new and install crash guardrails on the ends of each pallet rack row. Guardrails must be tested to withstand a minimum 10,000 lb impact at 4 mph. Each guardrail will consist of two ends I-Beam support post forty-two (42) inches tall with Two (2) 12-inch high-corrugated 10-gauged steel rails between each post. Each post is secured in the concrete floor with four (4) bolts to ensure its ability to withstand a 10,000 Lb impact at 4 mph. Guardrails will be the following lengths in the quantities stated. Installed guard rails lengths are measured outside to outside post 83-INCH GUARD RAILS 18 EA 95-INCH GUARD RAILS 2 EA 37-INCH GUARD RAILS 6 EA 43-INCH GUARD RAILS 2 EA Fire sprinkler systems are installed within each row of pallet racks. The removal of each bay of uprights supports will require the removal and re-installation of two (2) support brackets attached to the pallet rack supporting part of the sprinkler system piping. Trident Refit Facilities, Kings Bay, GA. Facilities Department engineers and Base Operating Services Contractor, sprinkler systems technicians have surveyed the system in the rack and have determined up to tow (2) adjacent sprinkler pipe supports brackets can be removed at one time without providing additional support. Extreme caution must be exercised during the performance of this contract to ensure none of the piping of sprinkler heads are struck or damaged. Any grinding, cutting or hot work requires a daily ?Hot Work? authorization, approved by the Naval Base Fire Inspector. Hot work authorizations are requested through SUBASE Facilities at 912 573-2143 Completion of this work will require the securing of the fire sprinkler system each morning and the re-charging of the system at the end of each workday. Securing the sprinkler system must be requested through Trident Refit Facilities, Kings Bay, 14 days before work commences. To accomplish this scheduling, the contractor awarded this contract will have to notify the contract coordinator at BAE Systems at least 14 days before work can begin Two (2) pallet rack bays will be emptied initially to begin replacement repairs. As the replacement or repairs are being completed in the (1) bay, an additional bay will be emptied to prevent work delays for the installer. A schedule or work, citing the order in which rack bays will be replaced or repaired must be provided to the BAE Systems point of contact at least 10 days in advance prior to commencement of the contract Access to Bldg 6003 will be available from 06:30 am to 4:45 pm Monday thru Friday excluding holidays.52.222-35 EQUAL OPPORTUNITY FOR SPECIAL DISABLED VETERANS OF THE VIETNAM ERA AND OTHER ELIGIBLE VETERANS, 52.222-36 AFFIRMATIVE ACTION FOR WORKERS WITH DISABILITIES; 52.212-2 INSTRUCTION TO OFFERORS-COMMERICAL ITEMS; 54.212-4 CONTRACT TERMS AND CONDITIONS- COMMERICAL ITEMS; 52.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECTIVE ORDERS-COMMERICALS ITEMS, 52.22-21 PROHIBITION OF SEGREGATED FACILITIES, 52.222-26 EQUAL ACTION FOR WORKERS WITH DISABILITIES, 52.222-37 EMPLOYMENT REPORTS ON SPECIAL DISABLED VETERANS, VETERANS, VETERANS OF THE VIETNAM ERA AND OTHER ELIGIBLE VETERANS, 52.219-1 SMALL BUSINESS PROGRAM REPRESENTATIONS; 252.204-7004 REQUIRED CENTRAL CONTRACTOR REGISTRATION; 252.212-7001 CONTRACTOR TERMS AND CONDITIONS RERQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS APPLICABLE TO DEFENSE ACQUISITIONS OR COMMERCIAL ITEMS, 252.225-7001 BUY AMERICAN ACT AND BALANCE OF PAYMENT PROGRAM;NBZ081 TRIDENT REFIT SECURITY CLAUSE. (SEE NUMBER NOTE 1) Please contact Carolyn Walker at (912) 573-8517 for on-site visit Government reserves the right to base this award on all or none
- Place of Performance
- Address: TRIDENT REFIT FACILITY, BLDG 4027, NAVAL SUBMARINE BASE, KINGS BAY, GA
- Zip Code: 31547
- Zip Code: 31547
- Record
- SN00828888-W 20050615/050613212011 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |