Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 17, 2005 FBO #1329
SOLICITATION NOTICE

66 -- MASS SPECTROMETER SYSTEM

Notice Date
7/15/2005
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
DHS - Direct Reports, Office of the Chief Procurement Officer, Center for Domestic Preparedeness-AL, P.O. Box 5100 61 Responder Drive, Anniston, AL, 36205
 
ZIP Code
36205
 
Solicitation Number
HSHQSL-05-R-00003
 
Response Due
7/25/2005
 
Archive Date
8/9/2005
 
Description
This is a combined synopsis / solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Proposals are being requested and a written solicitation document will not be issued. This solicitation is issued as a request for proposal (RFP). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-04. The Center for Domestic Preparedness has a requirement for MASS SPECTROMETER SYSTEM. Items are as follows: (Brand Name or Equal) ? (equal needs to be compatible with Perkin Elmer) CLIN 0001 N6519100 - CLARUS 500 GAS CHROMATOGRAPH , 120V 50/60H, ASXL/TCSW Package, 120V Selection, N651000A GC w/Autosamp & PPC Clarus 500 Gas Chromatograph with Programmed Pneumatic Control (PPC) and integral liquid sampler. A microprocessor controlled gas chromatograph with a built-in autosampling system. Both the GC and autosampler are fully controlled from the instrument keyboard. Quantity (1), Unit EA Includes: N65110F0 Split/Splitless w/PPC, Channel A - Single programmable split/splitless (PSS) injector with PPC and 1/16" male column fittings. N541100F Split/Splitless w/PPC, Channel B - Single programmable split/splitless (PSS) injector with PPC and 1/16" male column fittings. N651200H FPD with PPC, Channel B, Single flame photometric detector (FPD) with PPC. Includes amplifier and programmable pneumatic control for detector combustion gases. Also includes sulfur photomultiplier filter. N5413020 TotalChrom & Int LINK, Integral LINK for the Clarus 500 GC andTotalChrom Workstationn Software (TCWS) Kit. The Integral LINK provides digital-to-digital connection between the Clarus 500 GC and TotalChrom Workstation. Option includes Integral LINK, TotalChrom Workstation Software, Autosystem XL IPM for Clarus 500 GC and serial cable for connection to a computer. CLIN 0002 N6000981 - Phosphorus Lens Accessory, Quantity (1), Unit EA CLIN 0003 L4135472 - FPD Tin Filter Assembly, Quantity (1), Unit EA CLIN 0004 N6120105 - Autosampler Starter Kit, Quantity (1), Unit EA Includes: 5uL x 0.63mm o.d. syringe, 2mL clear sample vials (144), 2m: amber sample vials (100), blue crimp caps with septa (100), green crinp caps with septa (100), red crimp caps with septa (100), septa for waste wash vials (100), crimper - 11mm, decapper - 11mm, 2mL vial rack holder. CLIN 0005 N6120102 - PSS Starter Kit, Programmable split/splitless Injector starter kit Quantity (1), Unit EA Includes: Universal connectors (5), 0.53-mm i.d. deactivated fused silica (5), 2-mm i.d. liner, 1-mm i.d. liner, hourglass liner, 1/16" stainless steel nuts (5), 0.5-mm graphite ferrules (10), 0.8-mm graphite ferrules (10, viton o-rings (6), graphite o-rings (5), quartz wool, wafer scribes (10), septa (50). CLIN 0006 N6120104 - Detector Fittings Kit, Quantity (1), Unit EA Includes: 1/8" stainless steel nuts (2), 1/8" stainless steel plugs (2), 1/8" x .05mm graphite ferrles (10), 1/8" x 1.0mm graphite ferrules (10), 1/8"-1/16" adapter, 1/16" x 0.5mm graphite ferrules (10), 1/16" x 0.8 graphite ferrules (10), 1/16" stainless steel nuts (5). CLIN 0007 N6510120 - CLARUS 500 MS W/EI PCI NCI 120V, Quantity (1), Unit EA Mass spectrometer with Electron Ionization, Positive Chemical Ionization, and Negative Chemical Ionization. Includes state-of-the-art electronics and gold component technology, turbomolecular pump, Pirani and Penning gauges (high and low vacuum), Dell PC with Windows 2000, Monitor, 17" TurboMass software, shipping kit. CLIN 0008 N6520220 - S/W TURBOMASS NIST 02, Quantity (1), Unit EA CLIN 0009 09923518 - FILTER-VAPOR MIST NW25, Quantity (1), Unit EA CLIN 0010 N0207030 - CLARUS 500 MS/CLARUS 500 SYSTEM INSTALLATION, Quantity (1), Unit EA CLIN 0011 N0200417 - TRAINING-TURBOMASS OPERATOR, Quantity (1), Unit EA, New Inst Train Disc 4 day course conducted at a Perkin Elmer Technical Center. CLIN 0012 09404818 - Dell GX-280 Tower Win XP ? Quantity (1), Unit EA, USA Model: Del Optiplex GX-280, 2.8 GHz Intel Pentium 4, 800 MHz Front Side Bus (FSB), 1M L2 cache Chassis: Small Mini Tower (SMT) Factory Installed Operating System: Microsoft Windows XP Professional SP2 Memory: 512 MB, Non-ECC 400MHz, DDR2 2x256 Hard Drive: 80GB, SATA, 7200 RPM Networking Broadcom, 10/100/1000, Ethernet Remote Wake Up and PXE Support External I/O Ports: 8 USB 2.0 (2 rint, 6 rear), 1 Ethernet (RJ45), 2 serail (9-pin) (16550 compatible), 1 parallel (25-hole, bidirectional), 1 VGA out Expansion Slots: 3PCI up to 4.2 H x11.L, 1 PCIe x 1 up to 4.2. H x 9. L, 1 PCIe x 16 CDRW: 48x Max CD Rewriteable Drive Video: Intergrated video, Intel DVMT Floppy Drive 3.5" 1.44MB diskette drive standard Mouse: Dell USB 2-button optical mouse with scroll Keyboard: Dell USB Keyboard (No Hot Keys) Audio: Intergrated ADI 1981 AC97 codec Warranty: Next Business Day parts and Labor, on-site response for three years CLIN 0013 094037726 - Monitor-17 inch flat panel (US) LCD, Quantity (1), Unit EA CLIN 0014 09410001 - Cable PC to Printer Centronics Cable, Quantity (1), Unit EA 1.5m Parallel Centronics Cable for connection to printer to PC CLIN 0015 09421084 - PRINTER - HP Deskjet 6122 (Multi Voltage) Quantity (1), Unit EA CLIN 0016 N0207282 - On-Site Training, GC (per day) Quantity (4), Unit EA CLIN 0017 M0413603 - TURBOMATRIX THERMAL DESORBER, Quantity (2), Unit EA 120V Selection M0413324 Base Unit M0413336 Automated Therm Des Automated Thermal Desorber - Provides analytical capabilities equal to entry-level model along with an automated sample tube handling system for unattended decapping, analysis and recapping to up to 50 tubes. Tubes are capped at all times while in the sample tray. Overlaps desorption / preconcentration with GC analysis for higher productivity. Includes BCD output communication capabilities and timed event relays for timed control of external devices. M0413360 Manual Pneumatics Manual Pneumatic Control - Provides carrier gas pressure control via a precision pressure regulation valve. Split flow rates and primary desorption flow rates are controlled using precision needle valves. Pressure monitoring is accomplished with an electronic pressure sensor with pressure display provided on the user interface screen. M0413306 - LONG HEATED LINE Long Heated Transfer Line - (1800mm) for operation up to 300/C. 09991420 - Power Cord USA/CA M0413564 - Liquid Nitrogen Cool Liquid Nitrogen Cooling - For operation of the cold trap to - 100/C. Requires, but does not include the options board when aded to entry level thermal desorber. CLIN 0018 M0413541 - THERMAL DESORBER STARTER KIT, Quantity (2), Unit EA CLIN 0019 INSTALL ATD STAND ALONE, Quantity (2), Unit EA CLIN 0020 N6520030 - CLARUS 500 AUTOSAMPLER ADD ON KIT, Quantity (1), Unit EA CLIN 0021 N6120105 - AUTOSAMPLER STARTER KIT, Quantity (1), Unit EA Includes 5uL x 0.63mm o.d. syringe, 2mL clear sample vials (144), 2mL amber sample vials (100), blue crimp caps with septa (100), green crimp caps with septa (100), red crimp caps with septa (100), septa for waste wash vials (100), crimper - 11mm, decapper - 11mm, 2mL vial rack holder. CLIN 0022 N0207247 - INSTALL AUTOSAMPLER, Quantity (1), Unit EA Pricing should be FOB: Destination, Delivery should be within 60 days after receipt of order. Contractors must be registered in the Central Contractor Registration (CCR); the web site for registration is http://www.ccr.gov. If registration has not been accomplished use the following web site to access clauses that have been incorporated by reference: http://www.acqnet.gov All quotations must include a completed 52.212-3, Offeror Representations and Certifications / Commercial Items (Mar 2005) Offerors must to certify that they have completed their annual representations and certifications electronically via the ORCA website which is http://www.bpn.gov . The clause 52.212-4 (Oct 2003), Contract Terms and Conditions -- Commercial Items, applies to this acquisition and is incorporated by reference. The clause 52.212-5 (Jul 2005), Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items, applies to this acquisition and is incorporated by reference. Of the available clauses, the following apply and are incorporated by reference: 52.211-6 Brand Name or Equal (Aug 1999), 52.212-1 (Jan 2005), Instructions to Offeror -- Commercial Items; 52.219-14 (Dec 1996), Limitations on Subcontracting; 52.222-3 (Jun 2003) Convict Labor; 52.222-21 (Feb 1999), Prohibition of Segregated Facilities; 52.222-26 (Apr 2002), Equal Opportunity; 52.222-35 (Dec 2001), Affirmative Action for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-36 (Jun 1998) Affirmative Action for Workers with Disabilities; 52.222-37 (Dec 2001) Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-42 (May 1989) and 52.232-33 (Oct 2003) Payment by Electronic Funds Transfer-Central Contractor Registration. 52.212-2 Evaluation ? Commercial Items (Jan 1999); The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. Offerors must bid on all items in schedule to be considered. The following factors shall be used to evaluate offers: (1) Technical acceptability of item offered to meet Government requirement and (2) Price and price related factors. Inquiries and information received after the established deadline shall not be considered for this particular acquisition. Pursuant to the Brand Name or Equal clause; the offeror must provide descriptive literature of items being offered. Equal will be evaluated based on the information furnished by the offeror. If descriptive literature is not provided the offeror will be determined to be nonresponsive. Direct any questions (in writing) to Rickey Daniel@hq.dhs.gov . Proposals or alternate brand information must be submitted by mail/fax to Center for Domestic Preparedness ? 61 Responder Drive, Anniston, AL 36205 to be received no later than July 25, 2005 by 4:00 p.m. CST.
 
Place of Performance
Address: Department of Homeland Security, Center for Domestic Preparedness, P.O. Box 5100, Anniston, Alabama
Zip Code: 36205
Country: US
 
Record
SN00847923-W 20050717/050715211528 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.