Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 04, 2005 FBO #1347
SOLICITATION NOTICE

42 -- NOZZLE WITH SHUTOFF, COMBINATIOIN BARREL

Notice Date
8/2/2005
 
Notice Type
Solicitation Notice
 
NAICS
331312 — Primary Aluminum Production
 
Contracting Office
General Services Administration, Federal Supply Service (FSS), Southwest Supply Center (7FL), 819 Taylor Street RM 6A06, Fort Worth, TX, 76102
 
ZIP Code
76102
 
Solicitation Number
7FLA-S6-6603-SQ080205
 
Response Due
8/12/2005
 
Archive Date
12/31/2005
 
Description
This is a notice for standing quote agreement for the following item - date of award through January 31, 2006: NSN 4210-01-165-6603 NFES 1081 NOZZLE WITH SHUTOFF, COMBINATION BARREL: Shall be in accordance with Forest Service Specification 5100-239c dated October 2000, with the following characteristics: Size - 1" The color shall be red or maroon. First article sample(s) are required. Once first article samples have been accepted, Certificates of Conformance are acceptable in lieu of testing on a lot by lot basis. EXCEPTIONS TO FOREST SERVICE SPECIFICATION 5100-239c: Page 3, Paragraph 3.1, Delete and substitute the following: ?3.1 First article. Unless otherwise specified (see 6.2), the item shall be subjected to first article inspection in accordance with 4.4.3. During the term of the contract the contractor shall be required to notify the contracting officer in writing when a component, or the component supplier, changes in any way; when a major manufacturing process changes in any way; and when a manufacturing location changes. The contracting officer may at any time require the contractor to submit a new first article sample when substantive changes occur during the term of the contract.? Page 5, Paragraph 3.10.3, Proof Pressure, second line, delete ?no leaks? and substitute ?leakage not to exceed 3 drops per minute? in its place. Page 9, Paragraph 4.6.6, Proof Pressure Test, Last sentence, Delete and substitute the following: ?There shall be no leakage exceeding 3 drops per minute, permanent deformation, mechanical damage or structural failure.? In order to provide clarification to the sampling and inspection procedures as outlined within the referenced Forest Service specification and the industry standard cited therein (ANSI/ASQ Z1.4-2003), the following exceptions shall be incorporated. All references to "defect" (or "defects") shall be deleted and the term "nonconformity" (or "nonconformities") shall be substituted in its place. Similarly, all references to "percent defective" shall be changed to "percent nonconforming" and the phrase "defects per hundred units" shall be changed to "nonconformities per hundred units." The term "rejection" shall be changed to "nonacceptance" when it refers to a result of following the specified procedure. PACKAGING: Each nozzle shall be packaged in a close-fitting paperboard box. PACKING: Twenty (20) nozzles, packaged as specified, shall be packed in a close-fitting corrugated fiberboard box, minimum burst strength 275 psi (minimum edge crush strength 44 lb per inch width), and shall be in compliance with the Uniform Freight Classification and the National Motor Freight Classification. SPECIAL MARKING: The National Fire Equipment System (NFES) number appearing below the National Stock Number (NSN) of this Item Purchase Description shall be marked on the shipping container below the NSN. The NFES number shall be preceded by "NFES". MARKING: Shipments to GSA and other civilian agencies shall be marked in accordance with FED-STD-123. Shipments to the Department of Defense (DOD) shall be marked in accordance with MIL-STD-129. Palletization: The shipping (transport) containers shall be palletized. The pallets shall be 48-inch length x 40-inch width, general purpose, four-way entry, flush stringer, and double-face non-reversible pallets. The palletized load shall not exceed 2500 pounds in weight for shipments to the Eastern Distribution Center (Burlington). The palletized load shall not exceed 2000 pounds in weight for shipments to the Western Distribution Center (French Camp and Stockton Locations). The palletized load shall not overhang the pallet deck board edge by more than 1 inch and shall not exceed 53 inches in overall height (including pallet). Less than half pallet loads or loads shipped by small package carrier in acceptable transport packing need not be palletized. When less than full but more than a half pallet is used, the palletized load shall utilize proper bracing and/or reinforcement to ensure that the load can withstand two additional loads placed on it. Stacking: A load-stacking test shall be performed once, at the beginning of the contract, for each different unitized or palletized load configuration. A fully palletized load shall be tested utilizing a total stack of three palletized loads, with all the proper bracing and/or reinforcement necessary to perform the test. There shall be no evidence of damage to the pallets, shipping containers or products when stack is tested on the rigid surface for a minimum of 24 hours, in compliance with all the National and Local Safety Regulations. The pre-tested palletized load configuration shall be duplicated using the same packaging materials, pattern, number of shipping (transport) containers, and procedures consistent throughout the duration of the contract. Palletized loads shall be stable and safe when handled with mechanical equipment by qualified personnel. Materials: All lumber used inside or outside a shipment shall be bark free. No used wood pallets with repaired components or stringers will be acceptable. All wood pallet stringers shall be manufactured from hardwoods. Pallets manufactured of materials other than wood, shall conform to all the requirements specified herein. Unitization: For the purpose of this requirement, the assembled group of containers or items in a single load that can be handled as a unit throughout the distribution system. Unitization encompasses, but is not limited to, consolidation in a container, placement on a pallet or load base having forklift capability, or securely binding together. Shipments should be considered for unitization where appropriate or specified. Unitization of pallet load: The palletized load shall be unitized and secured to the pallet to insure that the load arrives intact without product damage. The containers or items shall be placed in a suitable pattern to form a stable and balanced load. Vertical, horizontal or filler reinforcement shall be added as necessary to meet the stacking strength requirements. A palletized load shall be secured to the pallet by shrink or stretch wrapping, and/or, by steel or nonmetallic strapping. When steel or nonmetallic strapping is used, edge protectors shall be provided to prevent damage to the cartons when tensioning the strapping. As a minimum, two straps shall run lengthwise, two straps shall run widthwise, and two straps shall run around the girth of the palletized load. A palletized load shall be capable of protecting the products against damage in a multiple handling, transportation, and storage environment having distribution warehouses with rack systems that support the load/s overhead of warehouse personnel. Notice of special requirements for shipment to all countries that have endorsed the IPPC Guidelines for treatment of non-manufactured wood packaging: The International Plant Protection Convention (IPPC) has approved and published on March 15, 2002, ?Guidelines for Regulating Wood Packaging Material in International Trade?. Countries endorsing the IPPC Guidelines are found at http://www.aphis.usda.gov/ppq/swp/. Clause D-FSS-468 requires non-manufactured wood pallets and other non-manufactured wood packaging material used in shipments destined to IPPC compliant countries require the appropriate wood treatment. Additionally, shipments delivered to DOD distribution facilities or freight consolidation points for eventual delivery to or through EU/IPPC countries shall comply with applicable DLA Regulations and Procurement Letter PROCLTR 02-17.
 
Record
SN00860717-W 20050804/050802212906 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.