SOLICITATION NOTICE
C -- DESIGN REPLACMENT OF BOILERS AND CONTROLS, BLDG 2210, MARINE CORPS LOGISTICS BASE, ALBANY, GA
- Notice Date
- 8/5/2005
- Notice Type
- Solicitation Notice
- NAICS
- 541330
— Engineering Services
- Contracting Office
- Department of the Navy, Naval Facilities Engineering Command, Engineering Field Division, South, ROICC Albany, Walker Avenue Building 5500, Albany, GA, 31704
- ZIP Code
- 31704
- Solicitation Number
- N62467-05-R-2107
- Response Due
- 9/5/2005
- Archive Date
- 9/20/2005
- Small Business Set-Aside
- Total Small Business
- Description
- This is a small business set-aside solicitation. One firm will be selected from this solicitation. Architect-Engineer or Engineering Services are required for preparation of plans; specifications, cost estimates, and all associated engineering services for a project to replace steam boilers for the Marine Corps Logistics Base, Albany, Georgia. Evaluation and definition of asbestos materials may be required. Subsequent preparation of plans and specifications may require definition of the removal and/or disposal process. Firms responding to this announcement must be prepared to accept the aforementioned as part of their contract responsibility; and The Government will reserve an option to negotiate construction inspection services and the preparation of Operating and Maintenance Support Information (OMSI) and/or as-built drawings. A-E firms responding to this announcement will be evaluated on the above requirements based on the following criteria in relative order of importance: (1) Professional qualifications (in-house personnel and/or consultants) necessary for satisfactory performance of required services; (2) Aggressive internal quality control program with demonstrated results of reducing design errors and/or omissions. Proven quality control of design documents. Performance on cost control in terms of budget control throughout the design efforts as well as bid results. Knowledge of the bid climate and related impact factors; (3) Recent specialized experience and technical competence of the firm in the design of mechanical/electrical systems for new and retrofit projects for industrial/commercial buildings (include government and private experiences.) List experience with similar projects successfully designed in the last five years; (4) Capacity to accomplish the work in the required time; as demonstrated by the impact of this workload of the firm's permanent staff, projected workload during the anticipated design period; the firm's history of successfully completing projects in compliance with performance schedules and providing timely construction support. Provide specific experience and relate time frames to accomplishment of similar design efforts. If consultants are involved, provide address history of working relationship; (5) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Demonstrated long term Government or private business relationship repeat business on related efforts and construction support; (6) Demonstrated success in prescribing the use of recovered materials and achieving waste reduction and energy efficiency in facility design; (7) Location of the firm in the general geographic area of the contract provided that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the contract; and (8) Volume of work awarded to the firm by the Department of Defense during the last 12-month period, with the objective of effecting equitable distribution of contracts among qualified Architect-Engineer firms. The work will be for work request # MB-04-5682, Replace Boilers and Controls In Steam Plant Building 2210. This work will involve the demolition of three (3) 750 horsepower steam boilers and replacement with new; removal of boiler controls and replacement with new; and the demolition and replacement with new for gas/oil burners, gas piping, pressure regulators and valves. The architectural floor plans for this building will be provided, as well as, existing mechanical/electrical drawings for the project area. Existing steam boilers are Cleaver Brooks Model D-24 L.H., were built in 1981 and installed in 1983. They produce 20,000 lbs per hour; furnace volume is 527 cubic feet and has a maximum working pressure of 260 psi. Burners are also by Cleaver-Brooks and are model number 200-BR-1 rated at 25,168 MBTU per hour, maximum. Type of contemplated contract: Firm-Fixed-Price. The title of this contract shall be ?DESIGN REPLACEMENT OF BOILERS AND CONTROLS AT BUILDING 2210, MARINE CORPS LOGISTICS BASE, ALBANY, GEORGIA.? Solicitation number is N62467-05-R-2107. Firms that meet the requirements described in this announcement are requested to submit a completed SF 330, U. S. Government Architect-Engineer Qualifications, to the office shown above. The SF 330 should clearly indicate the office location where the work will be preformed and the qualifications of the individuals anticipated to work on the contract and their geographical location. Firms responding to the announcement by close of business 5:00 PM EST, 5 SEPTEMBER 2005 will be considered. In the case where an insufficient numbers of SF 330?s are received, then firms having a current SF 330 Part II on file with this office may be requested to submit a SF 330 Part I. All Federal contractors must be registered in the Central Contractor Registration (CCR) database. New contract awards can only be made to contractors who are registered in CCR. The website for CCR is http:www.ccr.gov. This proposed contract is 100% set-aside for small business concerns. NAICS 541330. Size standard $4 Million. THIS IS NOT A REQUEST FOR PROPOSALS AND THERE IS NO SOLICATION PACKAGE. Inquires concerning this announcement should mention location and solicitation number. Surface mail should be addressed to the Officer in Charge of Construction, P.O. Box 43119, Marine Corps Logistics Base, Albany, Georgia 31704. Address all responses to ATTN: Code 02F0 Patty Morgans.
- Place of Performance
- Address: MARINE CORPS LOGISTICS BASE, ALBANY, GA,
- Zip Code: 31704
- Country: US