SOLICITATION NOTICE
J -- Annual maintenance on compressors, dryers, and filters
- Notice Date
- 8/10/2005
- Notice Type
- Solicitation Notice
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of the Air Force, Air Force Space Command, 21CONS (Bldg 982), Base Support Flight 700 Suffolk Street, STE 1200, Peterson AFB, CO, 80914-1200
- ZIP Code
- 80914-1200
- Solicitation Number
- FA2517-05-T-6046BURK
- Response Due
- 8/15/2005
- Archive Date
- 8/30/2005
- Description
- This requirement is being posted to find vendors to perform preventative maintenance each six months for all compressors, dryers, and filters as identified by serial number and model in the Statement Of Work (SOW). I have also included the Statement Of Work (SOW). STATEMENT OF WORK 302d Maintenance Group Compressor, Dryer, and Filter Maintenance 1. SCOPE. The contractor shall provide all labor, equipment, tools, materials, supervision, travel, freight and other items and services necessary to perform preventive maintenance and inspection of compressors, dryers, and filters located in various units within the 302d Maintenance Group buildings on Peterson AFB, Colorado. 2. SPECIFIC TASKS. The contractor will conduct all preventive maintenance and inspections at Peterson AFB, and will not remove compressors, dryers, or filters from the base to perform service. Each unit within the 302d Maintenance Group will provide an area for the vendor to perform the maintenance inspection. In the event that the vendor requires a larger area than provided, the vendor must request of the 302d Maintenance Group, in advance, the size area required to perform service. The majority of the service will be performed in the general location where the compressor is located. 2.1. The following service requirements per compressor and dryer shall be performed for inspections every six months: Check the condition of all belts and adjust the tension of all belts Check the condition of starter contacts and clean Check and record control panel parameters and warning shutdown history Check operation of system Record running amps and volts 2.2. The following additional service requirements per compressor and dryer shall be performed for preventive maintenance every six months: Adjust controls, wipe off any oil leaks and tighten as required Change oil and air filter Change separator element and coolant every 8000 hours or two years, whichever comes first, unless the differential gauge reflects that the separator needs to be changed Check fan motor and main motor, and lubricate Check condition of cooler and blow out, clean as required Check and clean condensate drain as required Take oil sample every 2000 hours Take standard preventive maintenance reading on Air End and Motor Provide a repair list by compressor and dryer for repair action Provide MSDS for all grease, lubricants, and potential hazardous materials prior to arrival so that a HazMart account can be established for this contract. Failure to adhere to these requirements may result in voiding of the maintenance contract. 3. WORK CONTROL The vendor will coordinate maintenance service with the 302d Maintenance Group POC in sufficient time for an area to be prepared to conduct the maintenance, and to allow disruption in the work area(s) to be kept to a minimum. Coordination by the vendor is imperative to ensure that the compressor, dryer, or filter may be placed in an inoperable status in order for the vendor to perform the maintenance or inspection. Hours of operation for the 302d Maintenance Group are 0700 through 1700 Monday through Friday. 4. DELIVERY AND INSPECTION/ACCEPTANCE. Contractor will notify the 302d Maintenance Group POC upon completion of work for inspection and acceptance. The 302d Maintenance Group POC is MSgt Gerald Tuttle, 719-556-7300. 5. GENERAL INFORMATION 5.1. ACCESS TO GOVERNMENT PROPERTY AND FACILITIES: The vendor will require non-escorted access to Government buildings 207, 208, 210, 214, 216, 502, and 888 on Peterson AFB consistent with service requirements. 5.2. PLACE OF PERFORMANCE. Work will be performed in Government facilities located at Peterson AFB, Colorado Springs, CO, as identified in 5.1. 5.3. EQUIPMENT INFORMATION. The make, model, serial number, and location of each compressor is as follows: Bldg 207 Compressor Make ? Speedair Model ? 5F565-2 Serial ? 0622941-871478 Dryer Model ? SR35 Serial ? 2758750001 Pre Filter ? MPF 35 Bldg 208 Compressor Make - REMCO Model ? M3-8 Serial ? 722-093 Dryer Model ? SR 50 Serial ? 2786990007 Pre Filter ? MPF 65 Bldg 210 Compressor Make - Sullair Model ? 6E10H-2 Serial ? E95006317 Compressor Make ? Sullair Model ? 6E10H-2 Serial ? E95006316 Dryer Make ? Sullair Model ? SR 50 Serial ? 2786990008 Pre Filter ? MPF 65 Bldg 214 Compressor Make ? Insersoll-Rand Model ? 2000E25 Serial ? 0309170002 Compressor Make ? Iron Horse Model ? 33252.3 Serial ? 427980 Dryer Make ? Honeywell Model ? 8010 Serial ? 0302A-48-8604-13N Dryer Make ? Insersoll-Rand Model ? TS100 Serial ? DR10013570-103102 Pre Filter ? IRHE123 Bldg 216 Compressor Make - Sullair Model ? 12BS-50H Serial ? 003-76671 Compressor Model ? HP30SE Serial ? JX4731U Dryer Make ? Wilkerson Model ? WRD75A-1 Serial ? 1013-06-10-1998-3292 Dryer Model ? UA150AC Serial ? U-8022 Pre Filter F30 for Sandblast Compressor Pre Filter F30 for Shop Air Compressor After Filter M30 for Shop Air Compressor Bldg 502 Compressor Make - REMCO Model ? 1060HT12-A3 Serial ? 00208854-60CT Dryer Make ? Sullair Model ? SR 50 Serial ? 2742410003 Pre Filter ? MPF 65 Bldg 888 Compressor Make ? Craftsman Portable Model ? 919.165200
- Place of Performance
- Address: Peterson AFB Colorado
- Zip Code: 80914
- Country: USA
- Zip Code: 80914
- Record
- SN00867285-W 20050812/050810212452 (fbodaily.com)
- Source
-
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)