Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 09, 2005 FBO #1383
MODIFICATION

41 -- HVAC Coils

Notice Date
9/7/2005
 
Notice Type
Modification
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, MD, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-05-Q-1026
 
Response Due
9/15/2005
 
Archive Date
9/30/2005
 
Point of Contact
Joni Laster, Purchasing Agent, Phone 301-975-8397, Fax 301-975-8884, - Michael Szwed, Supervisory Contract Specialist, Phone 301-975-6330, Fax 301-975-8884,
 
E-Mail Address
joni.laster@nist.gov, Michael.Szwed@nist.gov
 
Description
Solicitation SB1341-05-Q-0126 dated September 06, 2005 is hereby amended to address the following: (A) Vendor questions and answers as follows: Question: Are there any other attachments or specifications available for the required equipment, such as a specific brand, model, make & serial numbers for the units to replace the coils that the agency maybe looking for? Answer: Since these are not replacement coils, N.I.S.T. does not have any drawings for them. We can however, identify the brand and size of air handling unit that each coil will fit into and have added that to the description for each line item below: Line Item 0001: Quantity One (1) HVAC Coil: shall be labeled as HRC-201A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 20,690; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 3.0; (5) E.W.T (Degrees C) 12.2; (6) EHRW (L/S) 8.2; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 90; (10) Max W.P.D. (kPA) 47 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2894, Finned Length 3810. NOTE: THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 438/BB. Line Item 0002: Quantity One (1) HVAC Coil: shall be labeled as HRC-203A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 22,845; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 3.3; (5) E.W.T (Degrees C) 11.8; (6) EHRW (L/S) 8.7; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 60; (10) Max W.P.D. (kPA) 39 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2894, Finned Length 3810. NOTE: THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 474/BB. Line Item 0003: Quantity One (1) HVAC Coil : shall be labeled as HRC-204A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 20,100; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 3.0; (5) E.W.T (Degrees C) 12.3; (6) EHRW (L/S) 7.9; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 87; (10) Max W.P.D. (kPA) 44 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2894, Finned Length 3810. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 429/BB. Line Item 0004: Quantity One (1) HVAC Coil : shall be labeled as HRC-330A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 12,990; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.8; (5) E.W.T (Degrees C) 10.2; (6) EHRW (L/S) 6.1; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 65; (10) Max W.P.D. (kPA) 30 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2057.4, Finned Length 2844.8. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 275/BB. Line Item 0005: Quantity One (1) HVAC Coil : shall be labeled as HRC-332A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 8,260; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.3; (5) E.W.T (Degrees C) 14.4; (6) EHRW (L/S) 5.8; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 85; (10) Max W.P.D. (kPA) 38 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 1828, Finned Length 2235. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 175/BB. Line Item 0006: Quantity One (1) HVAC Coil shall be labeled as HRC-401A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 22,045; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 3.3; (5) E.W.T (Degrees C) 11.9; (6) EHRW (L/S) 9.1; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 62; (10) Max W.P.D. (kPA) 42 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2894, Finned Length 3810. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 467/BB. Line Item 0007: Quantity One (1) HVAC Coil : shall be labeled as HRC-403A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 23,335; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.9; (5) E.W.T (Degrees C) 11.6; (6) EHRW (L/S) 6.6; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 75; (10) Max W.P.D. (kPA) 26 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2894, Finned Length 3810. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 494/BB. Line Item 0008: Quantity One (1) HVAC Coil : shall be labeled as HRC-404A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 15,640; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.6; (5) E.W.T (Degrees C) 11.4; (6) EHRW (L/S) 6.0; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 85; (10) Max W.P.D. (kPA) 28 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2362, Finned Length 3429. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 331/BB. Line Item 0009: Quantity One (1) HVAC Coil : shall be labeled as HRC-523A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 14,790; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.6; (5) E.W.T (Degrees C) 11.2; (6) EHRW (L/S) 6.1; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 82; (10) Max W.P.D. (kPA) 29 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2362, Finned Length 2844. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 313/BB. Line Item 0010: Quantity One (1) HVAC Coil : shall be labeled as HRC-524A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 20,645; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 3.5; (5) E.W.T (Degrees C) 12.1; (6) EHRW (L/S) 7.8; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 52; (10) Max W.P.D. (kPA) 31 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2362, Finned Length 2134. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 437/BB. Line Item 0011: Quantity One (1) HVAC Coil : shall be labeled as HRC-525A and shall meet the following required specifications: (1) Media EHRW (40% ehtylene glycol exhaust heat recovery water); (2) Air Flow (L/S) 16,615; (3) E.A.T. (DB degrees C) 11.0; (4) L.A.T. (DB degrees C) 2.8; (5) E.W.T (Degrees C) 11.6; (6) EHRW (L/S) 6.8; (7) ROWS 6; (8) Fins per meter (max) 262; (9) Max A.P.D (PA) 82; (10) Max W.P.D. (kPA) 28 and (11) Overall dimensions in mm (total of multiple coils) Finned Height 2362, Finned Length 3352. THE BRAND/SIZE OF THE AHU IS A BUFFALOAIR HANDLING AHU SIZE/TYPE: 352/BB. (B) Extend the delivery date for the product until February 2006 and add the following additional line item: Line Item 0012: Quantity One (1) Lot: Monthly storage to hold the equipment identified within this solicitation for a total of up to 6 months. Note: The due date for submission remains unchanged and responses shall be received by 3:30 p.m. local time on September 15, 2005. Any questions or concerns regarding this solicitation and any amendments should be forwarded in writing via e-mail to the Purchasing Agent (Joni Laster) @ joni.laster@nist.gov. ***
 
Place of Performance
Address: 100 Bureau Drive,, Gaithersburg, MD
Zip Code: 20899
Country: USA
 
Record
SN00888801-W 20050909/050908033155 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.