Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 12, 2005 FBO #1386
SOURCES SOUGHT

73--73 -- Blast Chillers

Notice Date
9/10/2005
 
Notice Type
Sources Sought
 
Contracting Office
Attn: Department of Veterans Affairs National Acquisition Center, (049A1), P.O. Box 76, Building No. 37, Hines, Illinois 60141
 
ZIP Code
60141
 
Solicitation Number
VANAC-SSN-091005
 
Response Due
9/23/2005
 
Archive Date
10/23/2005
 
Small Business Set-Aside
N/A
 
Description
Sources Sought Notice for Blast Chillers. This is a Market Survey to locate potential sources currently holding FSS contracts for the standardization of various Blast Chillers. The Department of Veterans Affairs (VA) desires to offer its customers, on a national basis, the best possible products and prices and to offer its contractors more opportunities within the system. The intent of the standardization program is to establish national mandatory sources for Blast Chillers and to standardize purchasing of products. BIDS/OFFERS ARE NOT BEING SOLICITED AT THIS TIME. REQUEST FOR QUOTATIONS (RFQS) WILL BE ISSUED AT A LATER DATE. Potential offerors interested in having their items for possible inclusion in the standardization process should carefully review the Product Characteristic Specifications for Blast Chillers below. Offerors must have all three types of blast chillers available on FSS contracts that meet or exceed the specifications. Offerors who are interested in providing quotes should submit their intent at this time. All submissions of intent must be clearly marked with the name of potential offeror, the product number, and the manufacturer?s name. In addition, please provide company name, address, contact person and telephone number for questions. VA INTENDS TO AWARD BLANKET PURCHASE AGREEMENTS (BPAS) AGAINST FSS CONTRACTS RATHER THAN ISSUING FORMAL SOLICITATIONS FOR THE PURPOSE OF STANDARDIZATION. Service-disabled Veteran-owned Small Businesses and Small Businesses currently holding these FSS contracts are encouraged to participate. Please send responses to: Department of Veterans Affairs, ATTN: Timothy Richards, PO BOX 76, BLDG 37, First Avenue ? One Block North of Cermak Road (22nd Street) Hines, IL 60141 or email at Timothy.Richards@med.va.gov. Responses must be received no later than September 23, 2005. For additional information regarding contracting issues please contact Timothy Richards, Contract Specialist at (708) 786-4959 or Ronald E. Jenkins, Contracting Officer at (708) 786-4929. Product Characteristic Specifications for Blast Chillers: Style: Roll-in or Walk-in Blast Chiller Condenser: Self contained or remote. Type of cooler: Air cooled (water cooled as option for remote). Refrigerant: R404A. Chill Capabilities: Unit capacity chills product to 40 degrees F or less within 90 minutes. Chill Settings: Electronic, easy to use. By temperature, time, and/or product type. Autohold after temperature reached. Temperature Probes: Minimum of three probes. Defrost Cycle: Able to schedule cycle, not preset or automatic. Electrical: 208/230 Volts, 60 Hz, 30 Amps (or according to size). Body Composition: Interior and Exterior Stainless Steel; Insulated. Pan Slides, Wire Shelves, Wire Grids: Stainless Steel. Racks: Size or style possible (dimensions) or Proprietary rack, # of trays/pans possible. Capacity: 12 to 26 pans, depends upon rack and tray slide size. Display: Visual light, Visual temperature. Security: Audible alarm ? off temp Remote alarm. Doors and exterior features: Self-closing hinges; Closing latches and optional locks; Magnetic removable gaskets; Opening 90 to 120 degrees; Handle. Monitoring System: In-use temperature & time monitoring; On unit or wireless; NAFEM Data Protocol. Warranty: 5 year compressor. Service: Local Service Technicians. Training for Use & Maintenance: Manuals for Use & Maintenance ? On-site Training. Style: Reach-in Floor Model Blast Chiller ? 100 lb Capacity Condenser: Self contained. Type of cooler: Air cooled. Refrigerant: R404A. Chill Capabilities: Unit capacity chills product to 40 degrees F or less within 90 minutes. Chill Settings: Electronic east to use. By temperature, time, and/or product type. Autohold after temperature reached. Temperature Probes: Minimum of one probe. Defrost Cycle: Able to schedule cycle, not preset or automatic. Electrical: 208-230 Volts or 115 Volts, 60 Hz. Body Composition: Interior and Exterior Stainless Steel. Pan Slides, Wire Shelves, Wire Grids: Stainless Steel. Capacity: 10 pan (12? X 20? X 2 ??). Display: Visual light, temperature. Security: Audible alarm ? off temp. Doors and exterior features: Self-closing hinges; Closing latches and optional locks; Magnetic removable gaskets; Opening 90 to 120 degrees; Handle; Legs 6 inches minimum, casters optional. Monitoring System: In-use temperature & time monitoring; On unit or wireless; NAFEM Data Protocol. Warranty: 5 year compressor. Service: Local Service Technicians. Training for Use & Maintenance: Manuals for Use and Maintenance ? On-site. Style: Undercounter or Counter-top Model Blast Chiller ? 35 lb/16kg Capacity Condenser: Self contained. Type of cooler: Air cooled. Refrigerant: R404A. Chill Capabilities: Unit capacity chills product to 38 degrees F or less in under 2 hours. Chill Settings: Solid state electronic control panel, user friendly. Automatic or manual operation for either Soft Chilling, Hard Chilling or Shock Freezing. Autohold after temperature reached. Temperature Probes: Minimum of one probe. Defrost Cycle: Manual defrost cycle. Electrical: 208 Volts, Single Phase, 60 Hz, 7 Amps. Body Composition: Interior and Exterior Stainless Steel. Pan Slides, Wire Shelves, Wire Grids: Stainless Steel. Capacity: 4 (12? X 20? X 2 X 2 ??) deep food pans. Display: Visual light, temperature. Security: Audible alarm ? off temp. Doors and exterior features: Closing latches and optional locks; Magnetic removable gaskets; Legs 4? to 6? high stainless steel legs, casters optional. Monitoring System: In-use temperature & time monitoring; On unit; NAFEM Data Protocol. Warranty: 5 year compressor. Service: Local Service Technicians. Training for Use & Maintenance: Manuals for Use and Maintenance ? On-site.
 
Place of Performance
Address: National Acquisition Center P.O. Box 76, 1st Ave, 1 Block North of 22nd Street, Hines, IL
Zip Code: 60141
Country: United States
 
Record
SN00892185-W 20050912/050910211618 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.