Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 14, 2005 FBO #1388
SOLICITATION NOTICE

66 -- Emergency Lighting Inverters

Notice Date
9/12/2005
 
Notice Type
Solicitation Notice
 
NAICS
335129 — Other Lighting Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Mobility Command, 319 CONS, 575 Tuskegee Airmen Blvd, Building 418, Grand Forks AFB, ND, 58205
 
ZIP Code
58205
 
Solicitation Number
F2A3E35241A200
 
Response Due
9/17/2005
 
Archive Date
10/2/2005
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subparts 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation, proposals/quotes are being requested and a written solicitation will not be issued. The 319th Contracting Squadron at Grand Forks AFB, ND intends to award a firm fixed price purchase order for a brand name or equal purchase of an Emergency Lighting Inverter Illuminator Series E (fast Transfer), Emergency Lighting Inverter and the Illuminator Series IE (standard transfer). This solicitation is unrestricted in accordance with FAR Part 19. The Inverters must conform to the Buy American Act. Requirements are as follows: Emergency Lighting Inverter, Illuminator Series E (fast transfer) PN/6-E-4-S. Rating: 3750VA/3750W-Input:277VAC,60Hz,1 phase 2 wire+ground Output:277VAV,60Hz,1 phase 2 wire+ground-Battery: Sealed lead calcium,90 mins. Options included are none, quantity: 1 each. Emergency Lighting Inverter, Illuminator Series IE (standard transfer) PN/1-IE-4-S. Rating: 3750VA/3750W-Input:120VAC,60Hz,1 phase 2 wire+ground Output:120VAC,60Hz,1 phase 2 wire+ground-Battery: Sealed lead calcium,90 mins. Options included are none, quantity: 1 each Emergency Lighting Inverter Factory Turn-on, contractor is required to do a factory start-up and systems check on site. Will include operations and maintenance training for Civil Engineering personnel. Includes travel expenses. Factory Startup Services: An authorized technician shall perform the factory start-up service. Authorized technicians are fully trained on the customer?s equipment and are equipped with the proper test and diagnostic equipment. Should any problems be detected with the equipment during startup the factory technician will take corrective action to repair the affected components. The factory technician will carry spare parts for the specific system at the customer?s jobsite. Start-up services included: 1. System Integrity Check ? the journey for UPS starts at the loading dock and ends at the customer?s jobsite where it will be installed. In between, you have truckers moving it, roads bouncing it, movers positioning it, and contractors working in and around it. Supplier will take every precaution at the factory to ensure that the system is packaged securely. However, due to these uncontrollable forces, it is imperative that the system be checked at the onsite to ensure the integrity of the system, that no internal connections or wires have jostled loose and that all the components are properly secured physically and electrically. 2. Installation check ? after the system integrity check, the factory technician will verify that the installation meets all applicable performance and safety codes, including NEC, NFPA, IEEE, and UL. 3. Preload system check ? after the system installation has been verified, the factory technician will commence a preload test of the system. The preload test will verify proper performance of all system parameters under no-load or dummy load conditions. Dummy load tests must be prearranged with the factory. 4. Site load check after the system has been tested and calibrated under no load or dummy load conditions; the customer?s critical equipment is energized through the maintenance bypass (if available). The full operating current of the customer?s equipment is checked and verified not to exceed the rating of the UPS. 5. Site system check ? after the customer?s critical load has been verified it will be connected to the UPS. It will then be checked to ensure that under all operating conditions and power failure tests, that it performs all functions within its defined specifications and that the customer?s critical equipment is not affected. The customer equipment should be set up in test conditions to avoid potential loss of data and/or communications. Final calibrations to the system are made during this part of the test procedure. 6. Customer demonstration and training after the system has been functionally tested with the customer equipment, it is demonstrated to site personnel. This can include any parties responsible for the UPS, as well as any other party from facilities/maintenance, operations, MIS, etc. The training includes operational and maintenance instructions. After the training is complete, site personnel will be able to turn the system on and off, take it in and out of bypass, read and understand the front panel gauges, respond to the trouble situations, and properly maintain the system. The training will take approximately one (1) hour per session. It is recommended to keep class sizes under six (6) people. FUNDS ARE NOT PRESENTLY AVAILABLE FOR THIS REQUEST FOR QUOTE (RFQ). THE GOVERNMENT MAY CANCEL THIS RFQ AT ANY TIME IF FUNDS DO NOT BECOME AVAILABLE. IF FUNDS DO BECOME AVAILABLE THE GOVERNMENT WILL ISSUE A PURCHASE ORDER TO THE VENDOR WHO SUPPLIES THE SUCCESSFUL QUOTE, AND WE WILL ONLY BE AWARDING ONE CONTRACT. The Purchase Request number is F2A3E35241A200 and is issued as a Request for Quotation (RFQ). The solicitation document, incorporated provisions, and clauses are those in effect through the Federal Acquisition Circular 2005-05. The North American Industry Classification System (NAICS) code is 335129, size standard 500 employees. Offeror's must show: (1) The solicitation or reference number; (2) The time specified in the solicitation for receipt of offers; (3) The name, address, and telephone number of the offeror; (4) Price and discount terms (quote FOB Destination); (5) Remit to address, if different than the mailing address; (6) Warranty information; (7) Estimated delivery date; (8) Acknowledgement of solicitation amendments, if any, for acceptance of offers. The offeror agrees to hold the prices in its offer for 60 calendar days from the date specified for receipt of offers, unless another time period is specified in an addendum to the solicitation. Discussions may not be held with offerors; therefore, each offerors initial quote should be complete and accurate. Delivery is to be made FOB destination to Grand Forks AFB North Dakota and prices should include delivery. Anyone not quoting FOB Destination should include estimated freight/shipping cost with his or her quote. The required delivery date is 30 days after receipt of award. Offerors must provide warranty information specific to all equipment. The following provisions and clauses can be viewed through Internet access at the Air Force FAR Site, http://farsite.hill.af.mil. In Accordance with FAR 52.252-1 and FAR 52.252-2, the following provisions and clauses are incorporated by reference: FAR 52.212-1, Instructions to Offerors, Commercial Items. OFFERORS MUST INCLUDE WITH THEIR PROPOSAL A COMPLETED COPY OF THE PROVISION AT 52.212-3, OFFEROR REPRESENTATIONS AND CERTIFICATIONS-COMMERCIAL ITEMS, An offeror shall complete only paragraph (j) of this provision if the offeror has completed the annual representations and certificates electronically at http://orca.bpn.gov . If an offeror has not completed the annual representations and certifications electronically at the ORCA website, the offeror shall complete only paragraphs (b) through (i) of this provision, AND DFARS 252.212-7000 OFFEROR REPRESENTATIONS AND CERTIFICATION, COMMERCIAL ITEMS WITH THEIR QUOTE. 52.212-4, Contract Terms and Conditions -- Commercial Items. FAR 52.212-5 (Deviation), Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items; FAR 52.232-33, Payment by Electronic Funds Transfer-Central Contractor Registration; 52.247-34, F.O.B. Destination. In accordance with DFARS 252.204-7004, Alternate A, prior to receiving any contract award, contractors must be registered in the Central Contract Registration (CCR). If not already registered, you should immediately register with CCR via the Internet at http://www.ccr.gov/. Confirmation of CCR registration must be obtained before award can be made. DFARS 252.232-7003 Electronic Submission of Payment Requests. Department of Defense (DoD) Appropriations Act of 2001, Section 1008 Electronic Submission and Processing of Claims for Contract Payments requires that any claim for payment under a DoD contract shall be submitted in electronic form. Wide Area Workflow Receipt and Acceptance (WAWF-RA) is the DoD system of choice for implementing this statutory requirement. Use of the basic system is at NO COST to the contractor and training will be provided. Information available at no cost is located at http://www.wawftraining.com. DFARS 252.225-7001, DFARS 252.225-7002 Qualifying Country Sources as Subcontractors, Buy American Act and Balance of Payments Program, DFARS 252.225-7036; DFARS 252.225-7036, Buy American Act -- Free Trade Agreements Balance of Payments Program - Alternate I. Offers must be sent in writing/fax/e-mail to the Purchasing Agent, Irma Ferro, no later than 12:00 P.M. (CST) on 17 September 2006 to 319 CONS/LGCA3 - 575 Tuskegee Airmen Blvd, Grand Forks, ND, 58205, ATTN: Irma Ferro. For more information email irma.ferro@grandforks.af.mil or call at 701-747-5296. Fax 701-747-4215.
 
Place of Performance
Address: 319 CONS/LGCA3, ATTN: Irma Ferro, 575 Tuskegee Airmen Blvd, Grand Forks, ND
Zip Code: 58205
Country: USA
 
Record
SN00892890-W 20050914/050912212203 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.